HomeMy WebLinkAboutPitkin.EH.273504401013 (2018)Page | 1 Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 www.aspenpitkin.com/EHNR Parcel ID #: 2735-044-01-013 OWTS Use Permit #: 0036.2017.POWU Date Issued: 7/3/17 Issued By: Kurt Dahl Expiration Date: 7/3/18 Owner(s): Joel and Rita Cohen Property Address: 881 Cluny Dr Legal Description: Lot 13 East Owl Creek Subdivision Licensed Inspector: Carla Ostberg Inspection Date(s): March 31, April 3, and April 25, 2017 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete one-compartment tank 1000 Gallons Secondary Treatment Unit Concrete two-compartment septic tank 1000 Gallons Absorption Area Gravelless chamber soil treatment trenches (3) 15 Standard Chambers (45 total) 600 ft2 Other System Components Distribution Box OWTS Use Status: In use at the time of the inspection. Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: Date of Issuance: Date of Final Approval: # of Bedrooms or fixtures served by OWTS: System was originally designed to serve 4 bedrooms. Using today’s regulations the field area and tank are large enough to accommodate 5 bedrooms. Operational Status: According to the inspectors observation the system was functioning as designed at the time of inspection. An effluent filter was installed on the outlet of the septic tank. Inspector Recommendations: Department Recommendations: Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. 0036.2017.POWU 0036.2017. POW U CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 Y.:.: carla.ostberq_(agmail.com April 29, 2017 Chris Morrow chrisa-rutgersconstruction.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 881 Cluny Road Pitkin County, Colorado Chris, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 881 Cluny Road, Snowmass Village, Colorado on March 31, April 3, and April 25, 2017. The legal description of the 3.16-acre property is Lot 13, East Owl Creek Subdivision. The permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel ID #2735-044-01-013). The subject OWTS consists of one 1000-gallon, single -compartment concrete septic tank followed by one 1000-gallon, two -compartment concrete septic tank. Effluent gravity flows to a distribution box and then to three gravelless chamber trenches, each 90-feet long. Individual Sewage Disposal System Permit 93033 documents this system. The system was sized to accommodate 4 bedrooms. The permit received final approval on August 2, 1994. A clean out is located just outside of the foundation on the northwest side of the residence. The septic tanks are also located on the northwest side of the residence. At the time of our first two visits to the property, the septic tanks were not accessible from grade. The septic tank lids were excavated and made accessible for our inspection on April 25, 2017. Liquid levels in both septic tanks were normal at the time of our inspection. The first septic tank in the series will need 24-inches of risers and the outlet side 12-inches of risers to bring access within 8-inches of gradeThe second septic tank in the series will need 12-inches of risers on both the inlet and outlet sides of the septic tank. The existing riser on inlet side of the second tank needs to be replaced. Solid accumulation in the first septic tank warranted pumping. Altitude Septic pumped this tank at the time of our inspection. They removed dirt in the septic tank, to the extent possible. '. This septic tank has a mid -seam, below the normal waterline. There was minimal accumulation of solids in the second septic tank and this tank was not pumped. The inlet tee in the first septic tank is angled upward, indicating settling of the pipe outside of the septic tank. We also encountered a belly in the sewer pipe while running a camera through the pipe to locate the septic tank during a previous visit. We recommend excavating and re -bedding the trench from the house to the first septic tank. All other inlet and outlet tees were present. A large effluent filter was present on the outlet tee of the second septic tank. This filter is in disrepair. We recommend replacing the filter with an Orenco® Biotube Effluent filter (specifications included). We recommend manhole lid access be at grade; however, the project manager has requested 6-inches of cover over lids per recommendations from the landscaping company to maintain sod cover. Environmental Health Received 06/15/2017 0036.2017. POW U It should also be noted that the second septic tank in the series is installed backwards. Elevation of the inlet and outlet piping are appropriate, and there does not appear to be any issues with the flow through the septic tank despite the baffle wall being located in the first 1/3 of the septic tank. Effluent from the septic tank gravity flows under an existing, culverted irrigation ditch. This ditch was not running at the time of our inspection. The record drawing from Pitkin County indicates a distribution box. This distribution was not accessible at the time of our inspection; therefore, we were not able to inspect it. We recommend locating the distribution box and bringing it to grade for future inspection and monitoring. We walked the approximate soil treatment area (STA) and found no evidence of surface saturation or evidence of failure at the time of our inspection. Inspection ports are present at the end of each chamber trench. All ports were dry at the time of our inspection. There was a tree branch lodged in one of the ports. We removed the branch and recommend replacement of the cap on the port. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Required Repairs: • 1 st septic tank needs 24-inches of risers on inlet side and 12-inches of risers on outlet side. • 2"d septic tank needs 12-inches of risers on both inlet and outlet sides. Existing riser on inlet side needs to be replaced. Recommendations: • Excavate and re -bed trench for pipe from house to septic tank. • Install an Orenco® Biotube Effluent filter on the outlet tee of the second septic tank (specifications included). • Locate the distribution box and bring it to grade for future inspection and monitoring. • Replace removable cap on inspection port in STA. This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health Department electronically. The following are links to the required OWTS Use Permit Application and Checklist. Application: http://www.i)itkincounty.com/DocumentCenter/HomeNiew/621 Application Checklist: http://www.pitkincounty.com/DocumentCenter/HomeNiew/620 All questions regarding permit submission can be directed to Pitkin County Environmental Health Department, 970-920-5070. Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 110441TC Exp. April 2018 Environmental Health Received 06/15/2017 0036.2017. POW U A ' , P i Outlet tee on first tank (rise in disrepair) Inlet side of first tank (needs 24eet of risers) Inlet tee on second tank Environmental Health Received 06/15/2017 0036.2017.POWU view of STA (looking southwest) Three inspection ports (tree branch in one port — removed) View of STA looking northeast Environmental Health Received 06/15/2017 X O O W O CD C� A CD CTI O 00 N O O of V CD < 7 CD Q (D C 3 a 1 N = N (D O 2) 1 V5 S If no as -built drawings exist for this system or the as -built was inaccurate, please diagram the system as accurately as possible. Be sure to document ail system components and the location of any well on the property. Using markers such as corners of the house, exact measurements can be used to triangulate the location of the system components for future reference. 6 � 5 0 C. w N 0 V iz O C Rage 4 ti r- mac-. �•' _ �r �r � 3�;i r j n.yo i,x, K I N Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form ""'COUNT Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone:970-920-5070 Fax: 970-920-5374 Website: I http://pitkincounty.com/248[Wastewater-Treatment Inspection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number: Inspection Date: Inspector's Name: Business Name: Phone Number Email: Pitkin County Systems Joel and Rita Cohen 881 Cluny Road Snowmass Village, CO 2735 044 01 013 4/25/17 Carla Ostber CBO Inc. (970) 309-5259 carla.ostberg@gmail.com Inspector License Number: 1017 A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? ❑YES ONO If NO, how long has the home been vacant? How many bedrooms are in the home? 14 If secondary treatment is used, who is the maintenance provider? I n/a RECORDS: Were system records available from Pitkin County? AYES ❑NO If YES: Permit number: Date of Final Approval: 8/2/94 ISDS Permit 93033 # of bedrooms permitted: Was an as -built drawing available? 0 YES ❑ NO Is the as -built drawing accurate? ❑YES ❑NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: Proper grading, no evidence of erosion? OPASS ❑FAIL Improper vegetative cover? 0 NO ❑ YES Evidence of compaction such as heavy machinery or livestock? 0 NO ❑ YES Improper discharges such as straight pipes? ❑' PASS ❑FAIL Evidence of high ground water? 0 NO 0 YES Snow cover present? ❑ NO 0 YES Environmental Health Effective Date 1/12/2017 Received 06/15/2017 TANK: Tank 1 Tank 2 Tank 3 Tank capacity 1,000 =gallons 1,000 gallons gallons Tank material concrete (midseam) concrete # of compartments 1 2 Date of last pumping unknown unknown Lids/risers in good condition Fail Fail Select One Risers to grade No No Select One Riser height needed 2' / 1' needed 1' / 1' Riser condition/watertightness Inlet sanitary T/baffle Pass Pass Select One Outlet sanitary T/baffle Pass Pass Select One Effluent filter (if part of design) N/A Pass select One Condition of tank material Pass Pass Select One Tank was pumped for inspection Yes No Select One If YES, list the pumping company Altitude Septic If NO, when was the last pumping Scum level (1st compartment) inches 0 inches inches Sludge level (1st compartment) inches 4 inches inches Scum level (2nd compartment) inches 0 inches inches Sludge level (2nd compartment) inches 2 inches inches Backflow (if pumped) Pass Select One Select One Midtank baffle N/A Pass ISelect One Watertightness Pass Pass ISelect One midseam backwards PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present? ❑ YES NO If YES, is the pump/dosing siphon functioning properly? ❑PASS ❑FAIL Does the pump/wiring/dosing siphon appear to be in good condition? ❑PASS ❑FAIL Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL SECONDARY TREATMENT: Is a secondary treatment unit present? ❑YES 0 NO ❑UNKNOWN If YES, does the unit appear to be in good working condition? YES NO Does the owner have a current maintenance contract for the unit? YES H NO ❑UNKNOWN Maintenance Provider: n/a Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? OPASS ❑FAIL Evidence of past surfacing? E NO ❑YES Surface dampness? F. NO ❑ YES Excessive odors? 0 NO ❑ YES Field location verified by observation ports or probing: Ports ❑Probing Liquid in observation port? 0 NO ❑ YES If YES, record depth: 0 inches Distribution Box or ADV part of original design? 0 YES ❑ NO If YES, is it accessible from grade? YES ■ NO Is it level and in good condition? HPASS FAIL UNKNOWN Environmental° Health Received 06/15/2017 Effective Date 1/12/2017 ;cond septic tank installed backwards (elevations of inlet and outlet pipes OK) pe from house to first tank has settled in a couple places causing low spots that hold water 'lease list any recommendations for the continued use of the system: • Excavate and re -bed trench for pipe from house to septic tank. • Install an Orenco® Biotube Effluent filter on the outlet tee of the second septic tank (specifications included). • Locate the distribution box and bring it to grade for future inspection and monitoring. Were any repairs done as a result of this inspection? ❑ NO 0 YES If YES lease describe the repairs. • 1 st septic tank needs 24-inches of risers on inlet side and 12-inches of risers on outlet side. • 2nd septic tank needs 12-inches of risers on both inlet and outlet sides. Existing riser on inlet side needs to be replaced. (documentation of repairs must be provided by a Pitkin County Licensed Systems Contractor) To the best of my knowledge and training, the information collected in this inspection is accurate as of April 29 1, Zp 17 1. barg Licensed Systems Inspector Signature: Carla Ostber Digitallygned Carla:21:03 [06'0 Y p g g Date: 2017.04.2911 21:03 O6'00' Additional Notes: Clearly label any pictures and attach them to this form. Save Form Clear Form Print Form Environmental Health Received 06/15/2017 Effective Date 1/12/2017 LOWER LEVELFINISH ANDFURNITUREIA.1.1cSCALE:LOWER LEVELFURNITURE PLANI3/16" = 1'-0"SCALE:LOWER LEVELFLOOR FINISH PLAN23/16" = 1'-0"NORTHTITLESCALE:GENERAL CONTRACTORABCDARCH-D (24"X36")PROJECTISSUANCESDESCRIPTIONNO.DATEISSUED FOR2017 COPYRIGHT N|C|H| DESIGN LLC12341234ABCD 1.2.01.17ISSUE FOR PERMITCOHENRESIDENCE0881 CLUNY RDASPEN, CO81611ADDRESS2.4.03.17ISSUE FOR BUILD V1FP-01.1FLOOR PREPDEMO FOR NEW FINISHESFP-01.2FLOOR PREPINSTALL OWNERS CARPETBEDROOMS AND FAMILY ROOMFP-01.3FLOOR PREPINSTALL TILE & GROUTWALLSFP-01.4FLOOR PREPINSTALL TILE & GROUTFLOORSFP-01.5FLOOR PREPINSTALL TILE & GROUTEXTERIORFP-01.6FLOOR PREPINSTALL STAIR TREAD EXTERIORFP-01.7FLOOR PREPREFINISH STAIR TREADSSTAIRSFP-01.8FLOOR PREPSELF LEVEL, & UNDERLAYTILE AND WOOD FLOOR AREASFC-02FLOORINGTILEPOWDER ROOM LLFC-04.BFLOORTILEBATH LL01FC-04.DFLOORTILESHOWER FLOOR BATH LL01FC-6FLOORCARPET PADALL CARPET AREASFC-07FFLOORCARPETLOWER LEVEL FAMILY ROOMFC-07FFLOORCARPETGUEST BEDROOM LL01FC-09AFLOORTHESHOLD STONEBATHROOMS TBDFC-09CFLOORTRIMS - METAL TRIMSTBDFC-09DFLOORTREAD STAIRS REFINISHSTAIRCASESFC-10AFLOORHEAT MATBATHROOMS TBDFC-10CFLOORTILE BASEGUEST BATHSFLR-FLOOR COVERINGSPT-01PAINT -INTERIOR WALL COLOR INTERIORALL WALLSPT-02PAINT - INTERIOR CEILING INTERIOR ALL CEILINGSPT-03PAINT - INTERIOR WINDOW TRIM INTERIORALL WINDOW TRIMSPT-04PAINT - INTERIOR DOORS INTERIORDOORSPT-05PAINT - INTERIOR FRAMESFRAMESPT-06PAINT - INTERIOR BASE AND CASINGSBAR SOFFITSPT-07PAINT - INTERIOR HAND RAIL HAND RAILPT-PAINT0036.2017.POWU NORTHTITLESCALE:GENERAL CONTRACTORABCDARCH-D (24"X36")PROJECTISSUANCESDESCRIPTIONNO.DATEISSUED FOR2017 COPYRIGHT N|C|H| DESIGN LLC12341234ABCD 1.2.01.17ISSUE FOR PERMITCOHENRESIDENCE0881 CLUNY RDASPEN, CO81611ADDRESS2.4.03.17ISSUE FOR BUILD V1MAIN LEVELFURNITUREPLANIA.1.4.b0036.2017.POWU NORTHTITLESCALE:GENERAL CONTRACTORABCDARCH-D (24"X36")PROJECTISSUANCESDESCRIPTIONNO.DATEISSUED FOR2017 COPYRIGHT N|C|H| DESIGN LLC12341234ABCD 1.2.01.17ISSUE FOR PERMITCOHENRESIDENCE0881 CLUNY RDASPEN, CO81611ADDRESS2.4.03.17ISSUE FOR BUILD V1UPPER LEVELFINISH & FURNPLANIA.1.3cPT-01PAINT -INTERIOR WALL COLOR INTERIORALL WALLSPT-02PAINT - INTERIOR CEILING INTERIOR ALL CEILINGSPT-03PAINT - INTERIOR WINDOW TRIM INTERIORALL WINDOW TRIMSPT-04PAINT - INTERIOR DOORS INTERIORDOORSPT-05PAINT - INTERIOR FRAMESFRAMESPT-07PAINT - INTERIOR HAND RAIL HAND RAILPT-PAINTFP-01.1FLOOR PREPDEMO FOR NEW FINISHESFP-01.2FLOOR PREPINSTALL OWNERS CARPETBEDROOMS AND FAMILY ROOMFP-01.3FLOOR PREPINSTALL TILE & GROUTWALLSFP-01.4FLOOR PREPINSTALL TILE & GROUTFLOORSFP-01.5FLOOR PREPINSTALL TILE & GROUTEXTERIORFP-01.6FLOOR PREPINSTALL STAIR TREAD EXTERIORFP-01.7FLOOR PREPREFINISH STAIR TREADSSTAIRSFP-01.8FLOOR PREPSELF LEVEL, & UNDERLAYTILE AND WOOD FLOOR AREASFC-03FLOORTILEBATH 201FC-03FLOORTILEBATH 202FC-04.AFLOORTILESHOWER FLOOR BATH 201FC-04.AFLOOR TILESHOWER FLOOR BATH 202FC-6FLOORCARPET PADALL CARPET AREASFC-07BFLOORCARPETUPPER LEVEL TV /WALL BED AREAFC-07CFLOORCARPETGUEST BEDROOM 201FC-07DFLOORCARPETGUEST BEDROOM 202FC-09AFLOORTHESHOLD STONEBATHROOMS TBDFC-09CFLOORTRIMS - METAL TRIMSTBDFC-09DFLOORTREAD STAIRS REFINISHSTAIRCASESFC-10AFLOORHEAT MATBATHROOMSFC-10CFLOORTILE BASEGUEST BATHSGL-FLOOR COVERINGSSCALE:UPPER LEVELDEMO RCP PLANI3/16" = 1'-0"SCALE:UPPER LEVELNEW RCP PLAN23/16" = 1'-0"0036.2017.POWU INVOICE Date 5/30/2017 Invoice # 1332 Bill To 881 Cluny Rd Altitude Septic, LLC PO Box 1534 Eagle, CO 81631 Due Date 5/30/2017 Total Balance Due Payments/Credits 970-471-0913 AltitudeSeptic@gmail.com AltitudeSeptic.com DescriptionQuantity Unit Price Amount Labor & Equipment8 210.00 1,680.00 Filter, adapter, handle, and installation1 149.59 149.59 12" Risers and installation for adapting to existing risers3 55.80 167.40 Lids and installation3 27.00 81.00 4" concrete adapter ring and installation1 66.34 66.34 12" risers and installation for mounting to top of tank2 37.765 75.53 Lid and installation for above risers1 42.92 42.92 Rub'r Nek sealant and installation3 15.60 46.80 Locating of distribution box1 360.00 360.00 1 ton for bedding line1 17.555 17.56 To haul gravel3 80.00 240.00 Additional charges for installing a new distribution box Distribution box, risers, and misc parts delivery and installation1 268.57 268.57 Labor hand digging4 150.00 600.00 Any balance not paid in 30 days will incur a 3% interest charge. $3,795.71 $3,795.71 $0.00 0036.2017.POWU