Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2735-044-01-013
OWTS Use Permit #: 0036.2017.POWU
Date Issued: 7/3/17
Issued By: Kurt Dahl
Expiration Date: 7/3/18
Owner(s): Joel and Rita Cohen
Property Address: 881 Cluny Dr
Legal Description: Lot 13 East Owl Creek Subdivision
Licensed Inspector: Carla Ostberg
Inspection Date(s): March 31, April 3, and April 25, 2017
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete one-compartment tank 1000 Gallons
Secondary Treatment Unit Concrete two-compartment septic
tank
1000 Gallons
Absorption Area Gravelless chamber soil treatment
trenches
(3) 15 Standard Chambers (45
total) 600 ft2
Other System Components Distribution Box
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: Date of Issuance: Date of Final Approval:
# of Bedrooms or fixtures served by OWTS: System was originally designed to serve 4 bedrooms. Using today’s
regulations the field area and tank are large enough to accommodate 5 bedrooms.
Operational Status: According to the inspectors observation the system was functioning as designed at the time of
inspection. An effluent filter was installed on the outlet of the septic tank.
Inspector Recommendations:
Department Recommendations:
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
0036.2017.POWU
0036.2017. POW U
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
Y.:.:
carla.ostberq_(agmail.com
April 29, 2017
Chris Morrow
chrisa-rutgersconstruction.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
881 Cluny Road
Pitkin County, Colorado
Chris,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 881 Cluny Road, Snowmass Village, Colorado on March 31, April 3, and April 25, 2017.
The legal description of the 3.16-acre property is Lot 13, East Owl Creek Subdivision.
The permit and record drawing was provided by Pitkin County Environmental Health Department (Parcel
ID #2735-044-01-013). The subject OWTS consists of one 1000-gallon, single -compartment concrete
septic tank followed by one 1000-gallon, two -compartment concrete septic tank. Effluent gravity flows to
a distribution box and then to three gravelless chamber trenches, each 90-feet long. Individual Sewage
Disposal System Permit 93033 documents this system. The system was sized to accommodate 4
bedrooms. The permit received final approval on August 2, 1994.
A clean out is located just outside of the foundation on the northwest side of the residence. The septic
tanks are also located on the northwest side of the residence. At the time of our first two visits to the
property, the septic tanks were not accessible from grade. The septic tank lids were excavated and
made accessible for our inspection on April 25, 2017.
Liquid levels in both septic tanks were normal at the time of our inspection. The first septic tank in the
series will need 24-inches of risers and the outlet side 12-inches of risers to bring access within 8-inches
of gradeThe second septic tank in the series will need 12-inches of risers on both the inlet and outlet
sides of the septic tank. The existing riser on inlet side of the second tank needs to be replaced.
Solid accumulation in the first septic tank warranted pumping. Altitude Septic pumped this tank at the
time of our inspection. They removed dirt in the septic tank, to the extent possible. '. This septic tank
has a mid -seam, below the normal waterline. There was minimal accumulation of solids in the second
septic tank and this tank was not pumped.
The inlet tee in the first septic tank is angled upward, indicating settling of the pipe outside of the septic
tank. We also encountered a belly in the sewer pipe while running a camera through the pipe to locate
the septic tank during a previous visit. We recommend excavating and re -bedding the trench from the
house to the first septic tank. All other inlet and outlet tees were present. A large effluent filter was
present on the outlet tee of the second septic tank. This filter is in disrepair. We recommend replacing
the filter with an Orenco® Biotube Effluent filter (specifications included).
We recommend manhole lid access be at grade; however, the project manager has requested 6-inches of
cover over lids per recommendations from the landscaping company to maintain sod cover.
Environmental Health
Received 06/15/2017
0036.2017. POW U
It should also be noted that the second septic tank in the series is installed backwards. Elevation of the
inlet and outlet piping are appropriate, and there does not appear to be any issues with the flow through
the septic tank despite the baffle wall being located in the first 1/3 of the septic tank.
Effluent from the septic tank gravity flows under an existing, culverted irrigation ditch. This ditch was not
running at the time of our inspection. The record drawing from Pitkin County indicates a distribution box.
This distribution was not accessible at the time of our inspection; therefore, we were not able to inspect it.
We recommend locating the distribution box and bringing it to grade for future inspection and monitoring.
We walked the approximate soil treatment area (STA) and found no evidence of surface saturation or
evidence of failure at the time of our inspection. Inspection ports are present at the end of each chamber
trench. All ports were dry at the time of our inspection. There was a tree branch lodged in one of the
ports. We removed the branch and recommend replacement of the cap on the port. This evaluation is
not a guarantee of future system performance. This inspection is good for one year.
Required Repairs:
• 1 st septic tank needs 24-inches of risers on inlet side and 12-inches of risers on outlet side.
• 2"d septic tank needs 12-inches of risers on both inlet and outlet sides. Existing riser on inlet side
needs to be replaced.
Recommendations:
• Excavate and re -bed trench for pipe from house to septic tank.
• Install an Orenco® Biotube Effluent filter on the outlet tee of the second septic tank
(specifications included).
• Locate the distribution box and bring it to grade for future inspection and monitoring.
• Replace removable cap on inspection port in STA.
This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County
Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health
Department electronically. The following are links to the required OWTS Use Permit Application and
Checklist.
Application: http://www.i)itkincounty.com/DocumentCenter/HomeNiew/621
Application Checklist: http://www.pitkincounty.com/DocumentCenter/HomeNiew/620
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 110441TC Exp. April 2018
Environmental Health
Received 06/15/2017
0036.2017. POW U
A ' ,
P
i
Outlet tee on first tank (rise in disrepair)
Inlet side of first tank (needs 24eet of risers)
Inlet tee on second tank
Environmental Health
Received 06/15/2017
0036.2017.POWU
view of STA (looking southwest)
Three inspection ports (tree branch in one port — removed)
View of STA looking northeast
Environmental Health
Received 06/15/2017
X
O O
W O
CD C�
A CD
CTI O
00 N
O
O of
V CD
< 7
CD
Q (D
C 3
a
1
N =
N (D
O 2)
1 V5 S
If no as -built drawings exist for this system or the as -built was inaccurate, please diagram the system as
accurately as possible. Be sure to document ail system components and the location of any well on the
property. Using markers such as corners of the house, exact measurements can be used to triangulate
the location of the system components for future reference.
6
� 5
0
C.
w
N
0
V
iz
O
C
Rage 4
ti
r-
mac-. �•' _ �r �r � 3�;i r
j n.yo
i,x, K I N Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
""'COUNT Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone:970-920-5070 Fax: 970-920-5374
Website: I http://pitkincounty.com/248[Wastewater-Treatment
Inspection form for continued use of an existing OWTS
Owner's Name:
Address:
Parcel Number:
Inspection Date:
Inspector's Name:
Business Name:
Phone Number
Email:
Pitkin County Systems
Joel and Rita Cohen
881 Cluny Road
Snowmass Village, CO
2735 044 01 013
4/25/17
Carla Ostber
CBO Inc.
(970) 309-5259
carla.ostberg@gmail.com
Inspector License Number:
1017
A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by
the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system
passes or fails.
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
Is the home currently occupied? ❑YES ONO
If NO, how long has the home been vacant?
How many bedrooms are in the home? 14
If secondary treatment is used, who is the
maintenance provider? I n/a
RECORDS:
Were system records available from Pitkin County? AYES ❑NO
If YES: Permit number:
Date of Final Approval: 8/2/94 ISDS Permit 93033
# of bedrooms permitted:
Was an as -built drawing available? 0 YES ❑ NO
Is the as -built drawing accurate? ❑YES ❑NO
If NO: Complete a drawing of the system on last page of this form as accurately as
possible.
Any question marked FAIL will require correction before an OWTS Use permit is issued.
SITE CONDITIONS:
Proper grading, no evidence of erosion? OPASS ❑FAIL
Improper vegetative cover? 0 NO ❑ YES
Evidence of compaction such as heavy machinery or livestock? 0 NO ❑ YES
Improper discharges such as straight pipes? ❑' PASS ❑FAIL
Evidence of high ground water? 0 NO 0 YES
Snow cover present? ❑ NO 0 YES
Environmental Health Effective Date 1/12/2017
Received 06/15/2017
TANK:
Tank 1
Tank 2
Tank 3
Tank capacity
1,000 =gallons
1,000
gallons
gallons
Tank material
concrete (midseam)
concrete
# of compartments
1
2
Date of last pumping
unknown
unknown
Lids/risers in good condition
Fail
Fail
Select One
Risers to grade
No
No
Select One
Riser height
needed 2' / 1'
needed 1' / 1'
Riser condition/watertightness
Inlet sanitary T/baffle
Pass
Pass
Select One
Outlet sanitary T/baffle
Pass
Pass
Select One
Effluent filter (if part of design)
N/A
Pass
select One
Condition of tank material
Pass
Pass
Select One
Tank was pumped for inspection
Yes
No
Select One
If YES, list the pumping company
Altitude Septic
If NO, when was the last pumping
Scum level (1st compartment)
inches
0
inches
inches
Sludge level (1st compartment)
inches
4
inches
inches
Scum level (2nd compartment)
inches
0
inches
inches
Sludge level (2nd compartment)
inches
2
inches
inches
Backflow (if pumped)
Pass
Select One
Select One
Midtank baffle
N/A
Pass
ISelect One
Watertightness
Pass
Pass
ISelect One
midseam backwards
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present? ❑ YES NO
If YES, is the pump/dosing siphon functioning properly? ❑PASS ❑FAIL
Does the pump/wiring/dosing siphon appear to be in good condition? ❑PASS ❑FAIL
Is the high water alarm working, both visible and audible? ❑PASS ❑FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present? ❑YES 0 NO ❑UNKNOWN
If YES, does the unit appear to be in good working condition? YES NO
Does the owner have a current maintenance contract for the unit? YES H NO ❑UNKNOWN
Maintenance Provider: n/a Phone:
If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A
copy of the contract must be submitted to Pitkin County Environmental Health Department.
ABSORBTION AREA:
Effluent surfacing?
OPASS
❑FAIL
Evidence of past surfacing?
E
NO
❑YES
Surface dampness?
F.
NO
❑
YES
Excessive odors?
0
NO
❑
YES
Field location verified by observation ports or probing:
Ports ❑Probing
Liquid in observation port?
0
NO
❑ YES
If YES, record depth:
0 inches
Distribution Box or ADV part of original design?
0
YES
❑
NO
If YES, is it accessible from grade?
YES
■
NO
Is it level and in good condition?
HPASS
FAIL
UNKNOWN
Environmental° Health
Received 06/15/2017
Effective Date 1/12/2017
;cond septic tank installed backwards (elevations of inlet and outlet pipes OK)
pe from house to first tank has settled in a couple places causing low spots that hold water
'lease list any recommendations for the continued use of the system:
• Excavate and re -bed trench for pipe from house to septic tank.
• Install an Orenco® Biotube Effluent filter on the outlet tee of the second septic tank
(specifications included).
• Locate the distribution box and bring it to grade for future inspection and monitoring.
Were any repairs done as a result of this inspection? ❑ NO 0 YES
If YES lease describe the repairs.
• 1 st septic tank needs 24-inches of risers on inlet side and 12-inches of risers on outlet side.
• 2nd septic tank needs 12-inches of risers on both inlet and outlet sides. Existing riser on inlet
side needs to be replaced.
(documentation of repairs must be provided by a Pitkin County Licensed Systems Contractor)
To the best of my knowledge and training, the information collected in this inspection is accurate as of
April 29 1, Zp 17 1.
barg
Licensed Systems Inspector Signature: Carla Ostber Digitallygned Carla:21:03 [06'0
Y p g g Date: 2017.04.2911 21:03 O6'00'
Additional Notes:
Clearly label any pictures and attach them to this form.
Save Form Clear Form
Print Form
Environmental Health
Received 06/15/2017
Effective Date 1/12/2017
LOWER LEVELFINISH ANDFURNITUREIA.1.1cSCALE:LOWER LEVELFURNITURE PLANI3/16" = 1'-0"SCALE:LOWER LEVELFLOOR FINISH PLAN23/16" = 1'-0"NORTHTITLESCALE:GENERAL CONTRACTORABCDARCH-D (24"X36")PROJECTISSUANCESDESCRIPTIONNO.DATEISSUED FOR2017 COPYRIGHT N|C|H| DESIGN LLC12341234ABCD 1.2.01.17ISSUE FOR PERMITCOHENRESIDENCE0881 CLUNY RDASPEN, CO81611ADDRESS2.4.03.17ISSUE FOR BUILD V1FP-01.1FLOOR PREPDEMO FOR NEW FINISHESFP-01.2FLOOR PREPINSTALL OWNERS CARPETBEDROOMS AND FAMILY ROOMFP-01.3FLOOR PREPINSTALL TILE & GROUTWALLSFP-01.4FLOOR PREPINSTALL TILE & GROUTFLOORSFP-01.5FLOOR PREPINSTALL TILE & GROUTEXTERIORFP-01.6FLOOR PREPINSTALL STAIR TREAD EXTERIORFP-01.7FLOOR PREPREFINISH STAIR TREADSSTAIRSFP-01.8FLOOR PREPSELF LEVEL, & UNDERLAYTILE AND WOOD FLOOR AREASFC-02FLOORINGTILEPOWDER ROOM LLFC-04.BFLOORTILEBATH LL01FC-04.DFLOORTILESHOWER FLOOR BATH LL01FC-6FLOORCARPET PADALL CARPET AREASFC-07FFLOORCARPETLOWER LEVEL FAMILY ROOMFC-07FFLOORCARPETGUEST BEDROOM LL01FC-09AFLOORTHESHOLD STONEBATHROOMS TBDFC-09CFLOORTRIMS - METAL TRIMSTBDFC-09DFLOORTREAD STAIRS REFINISHSTAIRCASESFC-10AFLOORHEAT MATBATHROOMS TBDFC-10CFLOORTILE BASEGUEST BATHSFLR-FLOOR COVERINGSPT-01PAINT -INTERIOR WALL COLOR INTERIORALL WALLSPT-02PAINT - INTERIOR CEILING INTERIOR ALL CEILINGSPT-03PAINT - INTERIOR WINDOW TRIM INTERIORALL WINDOW TRIMSPT-04PAINT - INTERIOR DOORS INTERIORDOORSPT-05PAINT - INTERIOR FRAMESFRAMESPT-06PAINT - INTERIOR BASE AND CASINGSBAR SOFFITSPT-07PAINT - INTERIOR HAND RAIL HAND RAILPT-PAINT0036.2017.POWU
NORTHTITLESCALE:GENERAL CONTRACTORABCDARCH-D (24"X36")PROJECTISSUANCESDESCRIPTIONNO.DATEISSUED FOR2017 COPYRIGHT N|C|H| DESIGN LLC12341234ABCD 1.2.01.17ISSUE FOR PERMITCOHENRESIDENCE0881 CLUNY RDASPEN, CO81611ADDRESS2.4.03.17ISSUE FOR BUILD V1MAIN LEVELFURNITUREPLANIA.1.4.b0036.2017.POWU
NORTHTITLESCALE:GENERAL CONTRACTORABCDARCH-D (24"X36")PROJECTISSUANCESDESCRIPTIONNO.DATEISSUED FOR2017 COPYRIGHT N|C|H| DESIGN LLC12341234ABCD 1.2.01.17ISSUE FOR PERMITCOHENRESIDENCE0881 CLUNY RDASPEN, CO81611ADDRESS2.4.03.17ISSUE FOR BUILD V1UPPER LEVELFINISH & FURNPLANIA.1.3cPT-01PAINT -INTERIOR WALL COLOR INTERIORALL WALLSPT-02PAINT - INTERIOR CEILING INTERIOR ALL CEILINGSPT-03PAINT - INTERIOR WINDOW TRIM INTERIORALL WINDOW TRIMSPT-04PAINT - INTERIOR DOORS INTERIORDOORSPT-05PAINT - INTERIOR FRAMESFRAMESPT-07PAINT - INTERIOR HAND RAIL HAND RAILPT-PAINTFP-01.1FLOOR PREPDEMO FOR NEW FINISHESFP-01.2FLOOR PREPINSTALL OWNERS CARPETBEDROOMS AND FAMILY ROOMFP-01.3FLOOR PREPINSTALL TILE & GROUTWALLSFP-01.4FLOOR PREPINSTALL TILE & GROUTFLOORSFP-01.5FLOOR PREPINSTALL TILE & GROUTEXTERIORFP-01.6FLOOR PREPINSTALL STAIR TREAD EXTERIORFP-01.7FLOOR PREPREFINISH STAIR TREADSSTAIRSFP-01.8FLOOR PREPSELF LEVEL, & UNDERLAYTILE AND WOOD FLOOR AREASFC-03FLOORTILEBATH 201FC-03FLOORTILEBATH 202FC-04.AFLOORTILESHOWER FLOOR BATH 201FC-04.AFLOOR TILESHOWER FLOOR BATH 202FC-6FLOORCARPET PADALL CARPET AREASFC-07BFLOORCARPETUPPER LEVEL TV /WALL BED AREAFC-07CFLOORCARPETGUEST BEDROOM 201FC-07DFLOORCARPETGUEST BEDROOM 202FC-09AFLOORTHESHOLD STONEBATHROOMS TBDFC-09CFLOORTRIMS - METAL TRIMSTBDFC-09DFLOORTREAD STAIRS REFINISHSTAIRCASESFC-10AFLOORHEAT MATBATHROOMSFC-10CFLOORTILE BASEGUEST BATHSGL-FLOOR COVERINGSSCALE:UPPER LEVELDEMO RCP PLANI3/16" = 1'-0"SCALE:UPPER LEVELNEW RCP PLAN23/16" = 1'-0"0036.2017.POWU
INVOICE
Date
5/30/2017
Invoice #
1332
Bill To
881 Cluny Rd
Altitude Septic, LLC
PO Box 1534
Eagle, CO 81631
Due Date
5/30/2017
Total
Balance Due
Payments/Credits
970-471-0913
AltitudeSeptic@gmail.com
AltitudeSeptic.com
DescriptionQuantity Unit Price Amount
Labor & Equipment8 210.00 1,680.00
Filter, adapter, handle, and installation1 149.59 149.59
12" Risers and installation for adapting to existing risers3 55.80 167.40
Lids and installation3 27.00 81.00
4" concrete adapter ring and installation1 66.34 66.34
12" risers and installation for mounting to top of tank2 37.765 75.53
Lid and installation for above risers1 42.92 42.92
Rub'r Nek sealant and installation3 15.60 46.80
Locating of distribution box1 360.00 360.00
1 ton for bedding line1 17.555 17.56
To haul gravel3 80.00 240.00
Additional charges for installing a new distribution box
Distribution box, risers, and misc parts delivery and installation1 268.57 268.57
Labor hand digging4 150.00 600.00
Any balance not paid in 30 days will incur a 3% interest charge.
$3,795.71
$3,795.71
$0.00
0036.2017.POWU