HomeMy WebLinkAboutPitkin.EH.264504303019 (2013)111'KIN COU N NSITE WASTEWATER TREAT. ANT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd- Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970. 920.5374 Permit #: 0002.2013.POW2 Parcel ID #: Permit Issued: Owner(s): Larry Property Address: Legal Description: 2645-043-03-019 NEW CDU [-]REPAIR ®REMODEL/ADDITION TANK ONLY ®FIELD ONLY AMENDMENT H utter 64 Katvdid Lane Size of Lot: 1.02 Lot 15. Block 1. Filing 1, Little Elk Creek Villaqe Size of Building: 1008 i.t2 Acres Detached Accessory Unit: Sq. Ft. Size of Accessory Unit: _ YES NO This system is designed to serve 5 bedrooms, 3 in the main home and 2 in the ADU Designed By Phone #: Fax #: All Serivice Septic Project #: 970-309-5259 Mailing Address: C1037 Dated PO Box 2844. Glenwood Sorinqs, CO Sq. Ft. 6/21/13 303--216-2796 Email Address: Carla. Ostberg(a gmail.com Perc Rate: .9 LTAR Profile Hole Depth Minimum Tank Capacity: 1400 gallons 8' Depth to Groundwater or Bedrock: , 8' Minimum Absorption Area: 625 ft2 w/ 50% reduction Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system will utilize the new tank 1500 gallon tank (permit #0024.2012.POWT) with a dosing pump added to the 2nd chamber. The pump will dose to a distribution box which must be level and accessible from grade. The D -box will then equally distribute effluent to 5 gravelless chamber trenches, each consisting of 13 "quick -4" chambers, 52' in length. 6' of undisturbed soil must be maintained between each trench. Trenches shall maintain 3' depth, leaving 2 feet of cover for shallow installation. The new fields area must maintain setbacks of 10' to the property line, 60' to the ditch, 110' to the well, and 10' to any dwelling. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owne!r(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 7/11/13 Expires: 7/11/14 Installer: License #: Reactivation Authorized by: Final Approval Issued By: Date: New Expiration Date: ElfieepaW ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd - Aspen, CO -81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitkinassessor.org : Company: tC r Is U- C (Sv C -T I bpi Purpose of Permit: NEW t,e F.EPAIR DUE TO FAILURE REMODEL/ADDTFION TANK ONLY FIELD ONLY Cost of System Repair or RemodellAddition (approximate): G ti x lou l9 i Property Address: T L L I+J . p f 1S'6t.s yK t1 S1 C. . O I i Lot Block: Filing: Subdivision: L t tn-c C L tt- C-nct. V Property Owner(s)`: i.. 4z,w ill'fw Email Address: Fv1r- vz'cLiYL u ,S h. coil Owner's Mailing Address: City, State, Zip: p Home Phone: Business Phone: S, ?,d.) M6 b - 16 `t '1-6 - 410 % — 10 U Contact information must be provided for the owner signing this application. Primary Contact PersontApplicant (if not owner): e ,As Company: tC r Is U- C (Sv C -T I bpi ContactfAppiicant Mailirg Address: City, State, Zip: 11 + Z- 6 A -t2. a cs G ti x lou l9 i Cell Phone: ILet — S Business Phone: Fax Number: Email Address: ) j Y. v c. £ a.r Gtir-e e, Building Permit # (if applicable): Lot Size (in acres) i • , Size of Building (square feet): Number of Potential Bedrooms: Detached Accessory Ur it? b4 -YES NO Size of Accessory Unit (square feet): Number of Potential Bedrooms in or Fixture List for the Accessory Unit: Water Source: PRIVATE WELL SURFACE WATER SPRING COMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): L CIK- Grz stkQIk Engineerin Firm: S Job Number. Phone Number. LAuA•P- Fax Number: Iz%t-%t t.vL; c © o _ 5 33 Mailing Address: a Qi> by. C' tate, Zipti NG JQZ`t trt N wtrW PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued If my application is found to contain any inaccurate, false, or misleading information. I understand that no construction maybe undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signature (Required): Date: OZa U13 Applicant Signature: Date: FOR OFFICE USE ONLY Received by EN/HR Staff: Fee & Receipt#: Date: G: Owls Mach 8, 2006 NEW REGS Office - A min Forms OWTS Const Forms OW S constructon permit applicationAs Updated: 10 7/08 0 0 POBox wood SpdmA 0091602 Ph 970619-5033RODFax303-216.27% June 21, 2013 Project No. C1037 Larry Huffer lkhuttergmsn.com Subsurface Investigation and Onsite Wastewater Treatment System Design 3 -Bedroom Residence + 2 Additional Future Bedrooms 64 Katydid Lane Pitkin County, Colorado Larry, ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater treatment system (OWTS) design for the subject property. The property is located outside of Basalt, in an area where OWTS are necessary. The subdivision is served by a community water system. SITE CONDITIONS A 3 -bedroom, single-family residence presently exists and is utilizing an existing OWTS. The septic tank was recently replaced (Pitkin County OWTS Permit 0024.2012.powt) and will remain in use for the new OWTS. There is a desire to upgrade the existing absorption area to accommodate future development of the property and an existing structure that will be used as an additional dwelling unit ADU). The existing absorption area will be abandoned. There is a ditch located on the southeast property boundary, running parallel to Capitol Creek Road. There must be a minimum of 60 -feet from this ditch to the absorption area, SUBSURFACE The subsurface was investigated by digging one 8 -foot profile pit and taking a soil sample from approximately 3 -feet below grade. A gradation analysis and hydrometer analysis was run by HP Geotech and results are detailed in a report dated June 12, 2013, Job No 113 064H. The materials encountered in the profile pit consisted of 1.0 -feet of root zone, underlain by dark brown, loose, moist, sandy gravel with small cobbles up to 4 -inches in diameter to a depth of 4 -feet, underlain by light brown, dense, stacked, platy sandy gravel to a depth of 6.0 -feet, underlain by light brown, loose, sandy gravel with cobbles up to 1 -foot in diameter to a maximum depth explored of 8 - feet. One very large boulder, 3 -feet in diameter, was encountered at approximately 4 -feet. No bedrock or groundwater was encountered. The gradation performed by HP Geotech shows the soil consists of 19% gravel, 49% sand, 17% silt, and 15% clay. A long term acceptance rate (LTAR) of 0.90 gal/sq. ft will be used to design the OWTS. Page 2 Photos of 8 -foot profile hole DESIGN SPECIFICATIONS The OWTS design is based on 5 -bedrooms. An average daily wastewater flow of 750 GPD will be used. The existing 1500 -gallon, two-compartment septic tank will remain in use. A Biotube® pump vault will be placed in the second compartment of the septic tank. Effluent will be pumped to a distribution box and then to five gravelless chamber trenches, each consisting of 13 Infiltrator® Quick -4' chambers. There must be at least 6 -feet of undisturbed soil between each trench. Trench installation shall remain shallow, not to exceed a depth of 3 -feet (2 -feet of cover over chambers). There must be a minimum of 60 -feet from the ditch to the absorption area. 6 -bedroom option: If a 6 -bedroom OWTS is desired, the minimum tank capacity will be 1690 gallons, the absorption area must be at least 750 square feet (with a gravelless chamber trench configuration and a pump), and the setback from the absorption area to the ditch must be at least 78 - feet. Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations, the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and this design. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating absorption systems, and any other components needing maintenance. The surface of the drain field should be seeded upon completion. Vegetation is an important factor in drain field performance. Erosion control should be practiced prior to and during re -vegetation. Geo - fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or materials should be placed on backfilled drain field. Livestock should not graze on the drain field. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a drain field. The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garbage disposal use should be minimized, and non -biodegradable materials Page 3 should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADDITIONAL CONSTRUCTION NOTES If design includes a pump, air release valves and weep holes should be installed to allow pump lines to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain field due to the potential to compact soil. Extensions should be placed on all septic tank components to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices is optimal. INSTALLATION OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county regulations. Requirements not specified in this report must follow applicable county regulations. The installer should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Please call with questions. Sincerely, ALL SERVICE, septic, LLC ems, (OS-t&Ag Carla Ostberg, MPH, REHS Reviewed Richard H CJ NM. June 12, 2013 CBO Inc. Attn: Carla Ostberg 33 Four Wheel Drive Road Carbondale, Colorado 81623 carla.ostber > c .gmail.com Subject: Laboratory Test Results, Hutter Residence Dear Mrs. Ostberg: Hepworth-Pawlak Geotechnical, Inc. 5024 County Road 154 Glenwood Springs, Colorado 81601 Phone.: 970-945-7988 Fax: 974-945-8454 Email: hpgco @hpgaotech,com Job No. 113 064H As requested, Hepworth-Pawlak Geotechnical, Inc. performed gradation and hydrometer analysis on a sample delivered to our laboratory by you. The services were performed in accordance with our agreement for professional engineering services to you, dated March 20, 2013. Results of the gradation and hydrometer analysis performed on the sample are presented on Figure 1. The sample tested has an USDA Soil Texture Classification of Gravelly Sandy Loam. If you have any questions or need further assistance, please call our office. Sincerely, HEPWORTH AWLAK GEOTECHNICAL, INC. Louis E. Eller LEE/ksw attachment Figure 1 — USDA Soil Texture Gradation Test Results Parker 30.3-841-7119 - Colorado Springs 719-633-5562 - Silverthorne 970- 465-1989 S* 40 Pump Selection for a Non -Pressurized System -Single Family Residence Project C1037 Hutter Parameters Transport Velocity 300 Discharge Assembly Size 1.50 inches Transport Length 75 feet Transport Pipe Class 40 Transport Line Size 2.00 inches Distributing Valve Modd None Loss in Transport Max Elevation Lift 10 feet Design Flow Rate 20 gpm 250 Flow Meter None inches Add-on' Friction Losses 0 feet Calculations Transport Velocity 1.9 fps 200 Frictional Head Losses Lossthrough Discharge 1.2 feet Loss in Transport 0.6 feet Loss through Valve 0. 0 feet Lossthrough Flowmeter 0. 0 feet 150 Add-on' Friction Losses 0.0 feet y Pipe Volumes Vol of Transport Line 13.1 gals 4 Minimum Pump Requirements 100 Design Flow Rate 20.0 gpm Total Dynamic Head 11.8 feet 04,61. pq 4r . i gid$ 50 0L 0 PumpData 5 10 15 20 25 30 35 Net Discharge (gpm) PF3005 High Head Effluent Pump 30 GPM, 1/2HP 115/230V 10 60Hz,200\/ 3060Hz PF3007 High Head Effluent Pump 30 GPM, 3/4HP 230V 10 60Hz, 2001460V 30 60Hz PF3010 High Head Effluent Pump 30 GPM,1HP 230V 10 60Hz, 200/460V 30 60Hz PF3015 High Head Effluent Pump 30 GPM, 1- 1/2HP 230V 10 60Hz, 200/230/460V 30 60Hz ena System Curve:— Pump Curve: Pump Optimal Rangem— Operating Point Design Point 40 H --- I i GRADATION TEST RESULTS h—Pewiak Geatechnical N 0' 20' 40' Scale: 1" = 40'-0" THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. DRIVE 3 -BED RES. 2 N2. 0 0 oADU 0 I 0 II SHED SITE PLAN .. - 40,_0 / UPROFILE'\ PIT L-- —J EXISTING DRAIN FIELD TO BE ABANDONED 7/ Date: 06/21/13 Designed By: CO Drawn Bv: ANG P.O. Box 2844 Hutter Residence Glenwood Springs, Colorado 81602 64 Katydid Lane \ n / OSeptCPhone970.618.5033 Snowmass, CO / / SERY E Fax 303.216.2796 I' J Project Number: C1037 Sheet 1 of 5 0' 10' 20' Scale: 1" = 20'-0" EXISTING TANK TO — REMAIN. ADD BIOTUBE PUMP VAULT DISTRIBUTION BOX— QUICK-4' CHAMBER TRENCHES. 13 CHAMBERS PER TRENCH = 65 CHAMBERS = 642 SF OBSERVATION — PORT, TYPICAL AT EACH TRENCH i n PROPOSED OWTS OLD TANK ABANDONED F-- Date: 06/21/13 Designed By: CO Drawn Bv: ANG P.O. Box 2844 Hutter Residence Glenwood Springs, Colorado 81602 64 Katydid Lane W2.0 / / . OPhone970.618.5033 Snowmass, CO W/ / SEBY CE Fax 303.216.2796 I' LL Project Number: C1037 Sheet 2 of 5 DRAIN FIELD CROSS SECTION - TYP. Ti u Z max L LIMIT OF EXCAVATION SCARIFY SURFACE INFILTRATOR(R) QUICK4(TM) CUT SHEET 4" PVC OBERVATION 12" 34" III II I II — II PIPE UNDISTURBED I SOIL 1' min 16" 126' min " 34° LINES TO ENTER GRAVELLESS'QUICK-4' AND EXIT IN TOP CHAMBER (4'x 3') PORT OF CHAMBER END PLATE QTRENCH DETAILS NOT TO SCALE PVC OBS. IIPE FLUENT PIPE M SEPTIC TANK RIBUTION S PLACED IN PORT OF AMBER END TES Date: 06/21/13 Designed By: CO Drawn By: ANG P.O. Box 2844 Hutter Residence Glenwood Springs, Colorado 81602 64 Katydid Lane W3.0 / / OS,ept C Phone 970.618.5033 Snowmass, CO / / SEBY E Fax 303.216.2796 p Project Number: C1037 Sheet 3 of 5 DESIGN EXISTING 3 -BEDROOM RESIDENCE 2 FUTURE ADDITIONAL BEDROOMS 75 GAL/PERSON/DAY x 2 PERSONS/BEDROOM x 5 BEDROOM) AVERAGE DAILY FLOW = 750 GALLONS DESIGN FLOW = Q = 1.5 x 150 = 1125 GALLONS TANK: 1125 x 30 HOUR RETENTION TIME = 1406 GALLONS USE EXISTING 1500 -GALLON, TWO-COMPARTMENT TANK ABSORPTION AREA: LONG TERM ACCEPTANCE RATE: 0.90 GALLONS/SQ FT CALCULATED ABSORPTION AREA = Q/0.90 = 1250 SF 50% REDUCTION, CHAMBERS IN TRENCHES WITH A PUMP TOTAL AREA REQUIRED = 625 SF 5 TRENCHES, 13 CHAMBERS LONG 65 TOTAL CHAMBERS ('QUICK -4') WIDTH OF TRENCHES = 1 CHAMBERS = 3 FEET WIDE 6' UNDISTURBED SOIL BETWEEN TRENCHES LENGTH OF TRENCHES = 13 CHAMBERS = 52 FEET LONG TOTAL FOOTPRINT = 39 FEET x 52 FEET 6 -BEDROOM OPTION Q= 6 BEDROOMS X 2 PEOPLE X 75 GAL/PERSON/DAY X 1.5 = 1350 GAL MIN TANK CAPACITY = 1690 GALLONS ABSORPTION AREA MINIMUM 750 SQ FT (76 -QUICK-4- CHAMBERS) IN A TRENCH CONFIGURATION WITH DOSING BOX AND COVER BROUGHT TO GRADE CONCRETE LID FINSHED GRADE O 0 O 1 \ INLET OUTLETS DISTRIBUTION BOX BAFFLE X DETAIL Date: 06/21/13 n D-BO T Nor To scnLE Designed By: CO Drawn By: ANG H11P.O. Box 2844 Hutter Residence Glenwood Springs, Colorado 81602 64 Katydid Lane W4.0 / / . OMEPhone970.618.5033 Snowmass, CO W/ / Fax 303.216.2796 Project Number: C1037 Sheet 4 of 5 ProPakT" Effluent Pumping System - 2nd Compartment Drawdown 0 n Scale: 1" = 2' cIncorporatedStems® Simplex Pumping System 814 AIRWAY AVENUE0,,— Control Panel Top View (NTS) SUTHERUN, OREGON 97479-9012 Splice Box w/Cord Grips TOLL FREE: Fiberglass Gasketed Lid with ( goo) 348- 9843 Stainless Steel Bolts Slope Ground TELEPHONE: Awa from Riser PVC Riser with Grommet(s) Away (541) 459-4449 Discharge Assembly FACSIMILE: 1_ (541) 459-2884 Conduit Seal Flexible Hose To Control Panel Effluent Discharge Inlet Tee Tank Adapter (Cast or Bolted) Level Control Float Assembly Filter Cartridge Vault Inlet Ports Orenco Effluent Pump BiotubEPPump Vault TANK DETAIL Date: 06/21/13 SCALY Designed By: CO Drawn By: ANG P.O. Box 2844 Hutter Residence p} Glenwood Springs, Colorado 81602 64 Katydid Lane W5.0 / / . O R SP.P L C Phone 970.618.5033 Snowmass, CO V / SERVICE Fax 303.216.2796 Project Number: C1037 Sheet 5 of 5 DESIGN CALCULATIONS - for Pitkin USING LTAR Owner's Name Parcel ID # House Size (sq. ft.) (75 gpd or 100 gpd) Number of Bedrooms in Main House Number of Offices, Libraries, Studies, Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 750 State Review Required? no LTAR no= (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 1125 E Minimum tank capacity 1406.25 gallons Absorption Area (=B20 X 1.0/1317) A = Q x 1.0 loading/LTAR A = 1,250 sq. ft. of absorption area required Absorptionti n (—Q 5 X SQRT .,...e rate) PATH SECONDARY TREATMENT (no leading f. ete ) A= x1,250 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel 1125 1250 114 127 Dosing 1000 1000 101 101 Chambers 1125 89 114 Max Allowable e2S 875 63 89 Secondary Treatment Abs Area w/ out loading factor (1328) Trench Bed Pipe and Gravel 1125 1250 114 127 Dosing 1000 1000 101 101 Chambers 875 1125 89 114 Max Allowable 625 875 63 89 110 SETBACK FROM WELL of feet = 60 SETBACK FROM POND, STREAM OR IRRIGATION DITCH of feet = 35 SETBACK FROM DRY GULCH of feet = CEH/ NRO r ;SITE WASTEWATER TREATN..VT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd. Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0024.2012.powt Parcel ID #: 2645-043-03-019 Permit Issued: []NEW CDU ®REPAIR FIRE MODE L/ADDITION ®TANK ONLY FIELD ONLY Owner(s). Larry Hutter r — Property Address: 64 Katydid Lane Legal Description: Lot '15, Block 1, Filing 1, Little Elk Creek Vi Size of Lot: 1.02 Acres Detached Accessory Unit: \ JOY Size of Building 10008 Sq. Ft. Size of Accessory Unit: ENDMENT Sq. Ft. The system is designed for: 2 bedrooms, this permit will not accommodate the building labeled shed/studio. The field area must be enlarged for the system to accommodate more than'L bedrooms Designed By Phone #: Fax #: All Service Septic Project #: 970-618-5033 Mailing Address: Email Address: Perc Rate: n/a 1046 Dated Profile Hole Depth: n/a Depth to Groundwater or Bedrock: Minimum Tank Capacity: n/a (see comments below) Minimum Absorption Area Permit Conditions: n/a 08/28/2012 n/a This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This permit is for the replacement of a collapsed, 1200 gallon concrete tank which is part of an existing and approved OWTS, permit #840090. The failed tank shall be properly abandoned and pumped and filled or crushed. The new septic tank is a 1500 gallon, 2 -chamber, plastic tank. It be installed in a different location than the existing failed tank and it shall be installed a minimum of 50' from all water ways or wells, 5' from any structures, and 10' from property lines. For the studio to be connected to the system, an additional permit must be applied for because upgrades must be made to the field area. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property ownE!r(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 9/25/ 12 Expires: 9/25/13 Installer'. § License #: r Reactivation Authorized by: P y Final Aroval Issued By, Date: New Expiration Date: Fine P id L.,dSITE WASTEWATER TREATMEN SYSTEM (OWTS) 30 CONSTRUCTION PERMIT APPLICATION EH/N j 76 Service Center Rd - Aspen, CO - 81611 MWPhone: 970.920.5070 Fax: 970.920.5374 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at www.pitk.inassessor.org : Company: Purpose of Permit: I NEW ,REPAIR DUE TO FAILURE REMODEL/ADDIFIONTANK ONLY F1 FIELD ONLY Cost of System Repair or Remodel/Addition (approximate): 44 OST is r c P l TArt) 11- pWrP MO fl 0 Property Address: kT (., taw C c L-x—r t% Lam« C'wc"tk- Lot: Block: Filing: Subdivision: 1 Lt. C Vf r Property Owner(s)': Email Address: 1 rru rL \3 Owner's Mailing Address: r City, State, Zip: Home Phone: p Business RhoRe: C a. Contact information must be provided for the owner siqninq -this application Primary Contact Person/Appl cant (if not owner): Company: Contact/Applicant Mailing Address: City, State, Zip: Cell Phone: Business Phone: Fax Number: Email Address: Building Permit # (if applicable): Lot Size (in acres): 0, Size of Building (square feet): Number of Potential Bedrooms: Detached Accessory Unit? NO —,— Size of Accessory Unit (square feet): YES O't r Number of Potential Bedrooms In or Fixture List for the Accessory Unit: Water Source: PRIVATE WELL SURFACE WATER SPRING J)J,OMMUNITY/PUBLIC WATER SYSTEM Name of Community/Public Nater System (if applicable): C. EngineeringEngineering Firm: Job Number: Phone Number: Fax Number: Mailing Address: City, State, Zip: PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. w Owner Signature (Required): / Date: t z G 'II Applicant Signature: Date: FOR OFFICE USE ONLY Received by EN/HR Staff: Fee & Receipt #: Date: G: OWTS March 8, 2008 NEW KEGS 0 'ce - Admin Forms OWTS Const Forms OWTS construction permit application.xls Updated: 10/7/08 Pitkin County Environmental Health Department Contact Log Sheet Mame: I)Aex- " / '/ -- E'arcei I©: Z C , °) Address: Date: QpPerson1S, ken To Coin eats /_Action to be Taken _ _ _ Initials Time9 e- HF,LTHY & _ Test for RadonGREEN www.epa.gov/radon it' lafr x; i 2kj-gg(o t e 4 `1 C 2-7- 3C> - Made from recycled paper Carla Ostberg From: Carla Ostberg Sent: Thursday, January 26, 2012 12:20 PM To: 'Larry Hutter' Subject: RE: 64 Katydid Thanks Larry, I think that explains things. I appreciate your time and attention to this matter. Carla Ostberg, MPH, RENS Pitkin County Environmental Health Manager new location!!) 76 Service Center Road, Aspen, CO 81611 970-920-5438 From: Larry Huffer [ mailt,:):lkhutter@msn.com] Sent: Thursday, January 26, 2012 11:58 AM To: Carla Ostberg Subject: RE: 64 Katydid Hi Carla The reason for the odor was that the top was broken and there was no cover. B&R was supposed to put a new one on for me. I am aware that when I upgrade, I will need a new leach field etc. I will be consulting with Avalanche, my architect as well as you and other County Officials. I want to make sure it is done in a legal and proper manor. I will probably not undergo the remodeling until a year from this Summer so we should be OK. I want the new septic system in first. Thanks for your consideration. Larry Lawrence K. Hutter Hutter Real Estate Services, Inc. 8525 East Baker Place Tucson, Arizona 85710 520-886-1644 office 520-906-4700 cell From: Carla Ostberg[mailto:Carla.Ostberg@co.pitkin.co.us] Sent: Thursday, January 26, 2012 10:45 AM To: Larry Hutter Cc: Carrington Brown; John Nielsen Subject: RE: 64 Katydid Thanks Larry, As long as the system is functioning, I am fine with waiting on the system replacement. I'm a little confused about B&R's recommendation to replace the tank. Do you know what reasoning they gave? There was also a concern about odors and I'm not sure that has been addressed. I would recommend adding tees, both inlet and outlet, as well as an effluent filter. The tees facilitate proper settling, and the effluent filter keeps solids from migrating to the field. I understand that an inspection of the L _.. i/shed is pending. The original system wzed to accommodate 2 bedrooms in 1972. If there are additional bedrooms on the property tied into the system, that may necessitate addressing the system sooner. Additionally, adding capacity to the house will not only require a change in tank capacity, but also absorption field capacity as there is currently only 600 square feet of pipe and gravel which does not meet minimum sizing requirements for more than 2 bedrooms. Thanks for the correction on the address. At least I went to the correct house when we looked at the tank! Please feel free to call me if you have any questions. Carla Ostberg, MPH, REHS Pitkin County Environmental Health Manager new location!!) 76 Service Center Road, Aspen, CO 81611 970-920-5438 i From: Larry Hutter mailto:lkhutter@msn.coml Sent: Thursday, January 26, 2012 10:26 AM To: Carla Ostberg Subject: RE: 164 Katydid Hi Carla I thought I had mentioned to you that I had the tank pumped last week. Sorry for the confusion. When the guy at B&R said that I needed to replace the tank now I was prepared to do just that even though the timing was not good for me. My intention was to replace the septic system this Summer after I have had a chance to sit down with my architect with plans for new construction. I want to put in the right size system to accommodate the new additions to the house. I am going to assume that I will need a larger tank because I anticipate adding more bedrooms. So if I had to replace the system now, I probably would have had to tear it out or modify it to handle the additional bedrooms. Since John, at Avalanche, said that I have a functioning septic system I think my best course of action will be to do the repairs and replace the entire system this Summer when I have a set of preliminary plans for the new construction that will allow me to put in the proper size unit for the number of bedrooms I anticipate building. I hope this meets with your approval. FYI the address is 64 Katydid and not 164. Regards, Larry Lawrence K. Hutter Hutter Real Estate Services, Inc. 8525 East Baker Place Tucson, Arizona 85710 520-886-1644 office 520-906-4700 cell From: Carla Ostberg mailto:Carla.Ostberg@co.pitkin.co.usl Sent: Wednesday, January 25, 2012 5:44 PM To: Ikhutter@msn.com Cc: John Nielsen; Carrington Brown Subject: 164 Katydid Hi Larry, After going out to the site today with John and Steve w/ Avalanche Excavation, we did determine the effluent level in the tank was lower than expected and assumed the tank was leaking. We assessed the best material, size, and location for a new tank. When Avalanche was gLcting their bid together, they called a local pLinping company (B&R) and discovered that the tank at the residence was recently pumped by them, which explains the lower than normal level. They then contacted the person who did the pumping and he confirmed the tank to be at a normal level prior to the pumping, but the top of the tank is somewhat in disrepair and there were odors coming from the tank. The tank appears to be holding water, but is somewhat in disrepair and replacing the top might only be a band-aid for now. You would have that: option as long as no other issues were discovered during the repair. The other alternative would be to go ahead and replace the tank. It is from 1972 and will only deteriorate further. A new tank would have good integrity and proper tees could be installed along with an effluent filter. Those components will assure proper settling in the tank and avoid any solids from entering the field, potentially prolonging the life (although we should also keep in mind that the field is 40 years old). Please let us know how you would like to proceed. Thank you, Carla Ostberg, MPH, REHS Pitkin County Environmental Health Manager new location!!) 76 Service Center Road, Aspen, CO 81611 970-920-5438 Email secured by Check Point Email secured by Check Point 100 SETBACK FROM WELL of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH of feet = 25 SETBACK FROM DRY GULCH of feet = OWTS DESIGN CALCULATIONS - for Pitkin Owner's Name jj€ Parcel ID # House Size (sq. ft.) (75 gpd or 100 gpd) 75 Number of Bedrooms in Main House Number of Offices, Libraries Studies Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 450 State Review Required? no Perc Rate BE= M Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 675 Minimum tank capacity 844 gallons Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 964 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 688 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel (-10%) 867 no red. 964 88 98 Dosing (-20%) 771 (-20%) 771 78 78 Chambers (-30%) 675 (-10%) 867 68 88 Max Allowable Lam 482(-30%) 675 49 68 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel (-10%) 620 no red. 688 63 70 Dosing (-20%) 551 (-20%) 551 56 56 Chambers (-30%) 482 (-10%) 620 49 63 Max Allowable (-50%) 344 (-30%) 482 35 49 100 SETBACK FROM WELL of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH of feet = 25 SETBACK FROM DRY GULCH of feet = 100 SETBACK FROM WELL of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH of feet = 25 SETBACK FROM DRY GULCH of feet = OWTS DESIGN CALCULATIONS - for Pitkin Owner's Name . Parcel ID # fi,5 House Size (sq. ft.) 29ammam (75 gpd or 100 gpd) 75 Number of Bedrooms in Main House Number of Offices, Libraries, Studies Similar -sized Rooms in Main House Number of Bedrooms in Detached Caretaker unit Number of Offices, Studies, Similar -sized Rooms in Caretaker Unit If the caretaker unit is ATTACHED, treat as if part of main house.) Average Daily Waste Flow 600 State Review Required? no Perc Rate (T) Design Flow (Q) = # potential bedrooms X 2 people/bedroom X gpd X 1.5 Q= 900 Minimum tank capacity 1125 gallons Absorption Area (=Q/5 X SQRT perc rate)(1.4 loading factor) A = 1,285 sq. ft. of absorption area required Absorption Area (=Q/5 X SQRT perc rate) WITH SECONDARY TREATMENT (no loading factor) A= 918 sq. ft. of absorption area required Abs. Area w/ loading factor (B25) Trench Bed Quick4 Trench Quick4 Bed Pipe and Gravel (-10%) 1156 no red. 1285 117 130 Dosing (-20%) 1028 (-20%) 1028 104 104 Chambers (-30%) 899 (-10%) 1156 91 117 Max Allowable ( m 642 (-30%) 899 65 91 Secondary Treatment Abs Area w/ out loading factor (B28) Trench Bed Pipe and Gravel (-10%) 826 no red. 918 84 93 Dosing (-20%) 734 (-20%) 734 74 74 Chambers (-30%) 642 (- 10%) 826 65 84 Max Allowable (-50%) 459 (-30%) 642 46 65 100 SETBACK FROM WELL of feet = 50 SETBACK FROM POND, STREAM OR IRRIGATION DITCH of feet = 25 SETBACK FROM DRY GULCH of feet = v OR 80 z(D O Uj rt0 n O r cn CD ru _ c o p 0 r CD O C rD W rD O_ 0 rL N0 O C r O rn v OR 80 z(D O Uj rt0 n O r cn CD ru _ cn Ulto z• 0 0 n Om CD O rD rDn0 rL N0 O v OR 80 z(D O Uj rt0 n O r cn CD ru _ cn Ulto rf o CS. O O C O rn 9.2' O Cr1 O n CD Opo CA CD o rO*Q CD yr. P ct. CL rD rD 0 5c Pl a< Loar tjd WHEELER LtTrt g' ayC Zme AACWOOJW d MASS g-Hcwir h49 G.mVt,..ro L rw aoaoaw , Ll. -LO I -z • ('o `'J 4` D ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) EH/NR CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd - Aspen, CO - 81611 Phone: 970.920.5070 Fax: 970.920.5374 Parcel ID# (available from the Pitkin County Assessor's Office 970-9205160 or at www.oitkinassessor.org): ' Purpose of Permit: 0 NEW ®,REPAIR DUE TO FAILURE REMODELJADDITION XTANK ONLY HELD ONLY Cost of System Repair or Remodel/Addition (approximate): Property Address: Lot: Block: Filing: Subdivision: 1 t L rte Ct_ C ti=t .c= V i Lt4kL25 Property Owner(s)*: Email Address: j L- ri i't cwLQ- i `t to N k _ l +V4e — i C Lt b Owner's Mailing Address: City, State, Zip: t If , 6AV-IrYl-Off- N G5 1 S T Home Phone: Business 111-io e: rj2,ci 1`f l 520 - q0L' Contact information must 5e provided for the owner signing "this application Primary Contact Person/Applicant (if not owner): WA Company: Contact/Applicant Mailing Address: City, State, Zip: Cell Phone: Business Phone: Fax Number: Email Address: Water Source: PRIVATE WELL SURFACE WATER SPRING t kOMMUNITYJPUBLIC WATER SYSTEM Name of Community/Public Water System (if applicable): L i r: t--fir- 1 i-1:- V L1 L Frr Engineering Firm: Job Number: Phone Number. Fax Number: Mailing Address: City, State, Zip: PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents included in my application package. 1 acknowledge that EFUNR may revoke any permit 1 am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. Owner Signature (Required): ? Date: z4>t Applicant Signature: Date: FOR OFFICE USE ONLY Received by EN/HR Staff: Fee & Receipt #: Date: G:\OWTS March 8, 2008 NEW REGS Office - Adrnin Forms\OWTS Const Forms OWTS construction permit applicatlon.xk Updated: 10/7/08 Loc -w Nd i WHEELER D a I-ar is tw.094--5 urrur pax cIcEK Q nx a rteWa+s '' 6f 14'PY n .tArtE ' j a Ski OklNlA4 j Gml GR1CiP Z.Kitwrfl aa wtmawo +o G G mr 506°21'01„W 121.2 ,S 3 sagg q` aNg FP Ails'% W o 1 0 ^+ fn oIS n tr7 a i E 0 OOm c p a b N N m Y a 8 y a m , ec• m. A b aw Oo Oto F o” QpO cz n p N cp SS` Wis n =. cr r10,21 M gL Cp n Gm LN D f e m n oQ. OOmcry oa b N N m Y tb a m , ec• m. A b aw GN A A Oto F o” QpO cz n p N c x amWis n =. cr 80 00D NN e m n oQ. f , 1 it RYR a a 0 Q 1