Loading...
HomeMy WebLinkAboutPitkin.EH.264504201005 (2017)Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5077 www.aspenpitkin.com/EHNR Parcel ID #: 2645-042-01-005 OWTS Use Permit #: 0002.2017.POWU Date Issued: 3/15/2017 Issued By: Kurt Dahl Expiration Date: 3/15/2018 Owner(s): Carl Radford Property Address: 91 Alexander Ave Legal Description: Lot 18 Block 3 Filing 2 Little Elk Creek Licensed Inspector: Carla Ostberg Inspection Date(s): 02/02/2017 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete two-compartment septic tank 1250 gallons Secondary Treatment Unit Absorption Area Gravelless chamber soil treatment trenches 48 Standard chambers (900 ft2) Other System Components Distribution box In use at the time of the inspection. Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 99039 Date of Issuance: 06/18/1999 Date of Final Approval: 10/04/1999 # of Bedrooms or fixtures served by OWTS: 4 Bedrooms (The system was designed to accommodate 3 bedrooms. However, based on the 2014 OWTS Regulations the system is adequately sized to accommodate 4 bedrooms. See attached Inspection report for further discussion). Operational Status: The inspector indicates the system is in good condition and there is no evidence of failure. The septic tank outlet side riser was replaced and the tank outlet tee was straightened. Inspector Recommendations: Verify access to distribution box is to grade, verify flow equalizers are present in the distribution box, verify pipe angle on septic tank inlet pipe. Department Recommendations: Annual Maintenance. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure.