Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2467-274-00-014
OWTS Use Permit #: 0052.2017.POWU
Date Issued: 8/25/17
Issued By: Bryan Daugherty
Expiration Date: 8/25/18
Owner(s): Inna Panichi Trust
Property Address: 406 Snowmass Creek Rd
Legal Description:
Licensed Inspector: Carla Ostberg
Inspection Date(s): 12/2/16, 7/26/17, 7/28/17
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete two-compartment tank 1000 gallons
Secondary Treatment Unit N/A N/A
Absorption Area Dry Well 589 ft2
Other System Components Pump Chamber 300 gallons
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 99044 Date of Issuance: 6/29/99 Date of Final Approval: 7/20/99
# of Bedrooms or fixtures served by OWTS: System is designed to serve 3 bedrooms.
Operational Status: After repairs were made including replacing the inlet tee in the tank, and adding risers to make the
tank accessible, and excavating the pump chamber the system appeared to be functioning as designed. Pump was
verified to be functioning as well as the alarm. The dry well appeared to be in good order with no evidence of surfacing
effluent.
Inspector Recommendations: Continued annual maintenance or as needed
Department Recommendations: N/A
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.