HomeMy WebLinkAboutPitkin.EH.264316401011 (2019)Page | 1
Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2643-164-01-011
OWTS Use Permit #: 020.2018.POWU
Date Issued: 5/14/2018
Issued By: Bryan Daugherty
Expiration Date: 5/14/19
Owner(s): Eric and Maggie Scheyer
Property Address: 111 Little Texas
Legal Description:
Licensed Inspector: Carla Ostberg
Inspection Date(s): 3/8/18
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Two-compartment concrete tank 1500 gallons
Secondary Treatment Unit
Absorption Area Sand filter bed 1684 ft2
Other System Components
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 98067 Date of Issuance: 10/7/1998 Date of Final Approval: 8/22/2000
# of Bedrooms or fixtures served by OWTS: This system was originally designed for 4 bedrooms but when sizing is
compared to new regulations the system is large enough to accommodate 5 bedrooms.
Operational Status: According to the inspectors observations at the time of the inspection the system was functioning
as designed. Both inlet and outlet tees were in place and tank was accessible from grade. The distribution box was not
accessible for inspection. The sand bed area did not show any signs of failure such as surfacing effluent.
Inspector Recommendations: Add an effluent filter to the outlet tee of the septic tank if possible. Locate distribution
box and bring access to grade for maintenance.
Department Recommendations: Annual maintenance.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
0020.2018.POWU
0020.2018.POWU
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259
carla.ostberg@gmail.com
April 2, 2018
Scott DeWind
scott@compass.cm.co
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
111 Little Texas Lane
Pitkin County, Colorado
Scott,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 111 Little Texas Lane, Woody Creek, Colorado on March 8, 2018. The legal description of
the 0.52-acre property is Lot 10, Little Texas Subdivision.
The permit and record drawing were provided by Pitkin County Environmental Health Department (Parcel
ID # 2463-164-01-011). The subject OWTS consists of one 1500-gallon1 two-compartment septic tank.
Effluent gravity flows to a distribution box and then to 10 rows of 8 ‘Standard’ Infiltrator® chambers on a
sand filter. Individual Sewage Disposal System Permit 98067 documents this system. The permit
received final approval on August 22, 2000. The system was sized to accommodate 4 bedrooms.
Previous inspections were conducted in 2012 and 2014. OWTS Use Permits 0029.2012.POWU and
0010.2014.POWU were issued after the these inspections were conducted.
Three feet of risers bring the septic tank manhole lids to grade. Both inlet and outlet tees were present.
We typically recommend adding an effluent filter; however, the outlet tee is tucked under the lid of the
septic tank making the installation difficult without extending the tee. The septic tank was pumped by
RotoRooter on January 12, 2018. Since that time, occupancy has been intermittent. We ran water
through the septic tank for approximately 30+ minutes and normal flow through was observed. They also
added a “bio kit treatment”. The product is distributed through Pro Pump (website screenshot and
RotoRooter invoices enclosed).
The distribution box was not accessible from grade. We recommend locating the distribution box and
brining access to grade for inspection and maintenance. The soil treatment area (STA) is covered with a
flagstone patio. Good vegetation is recommended above an absorption area; however, notes from Pitkin
County indicate the county was aware of the patio when they approved the system. One observation
port is present. The bottom of the absorption area is approximately 6-feet below grade and it was dry.
There was no evidence of surface saturation or failure at the time of our inspection. We also walked the
area below the STA and found no evidence of surface saturation or failure.
The addition of a 5th bedroom is proposed. There will be less than 6000 square feet of living area. Table
1 below compares the size of the existing OWTS to sizing requirements for 5 bedrooms with less than
6000 square feet of living area under current OWTS regulations.
1 Pitkin County ISDS Permit indicates a 2000-gallon septic tank was specified; however, RotoRooter’s invoice
notes 1500-gallons were pumped.
0020.2018.POWU
Table 1
Existing 2014 OWTS Regulations
Tank Size 1500-gallon tank, two-
compartment septic tank
Min. 1500 gallons
Soil Treatment Area
Gravity Fed Sand Filter
with Chambers
Infiltrative area: 10 rows of 8
‘Standard’ chambers = 1500 SF
Infiltrative area: Min. 1125 SF
using 0.8 gal/SF
2014 OWTS Regulation Calculations
75 GPD x 2 persons/bedroom x 5 bedrooms = 750 GPD
LTAR = 0.8 (Soil Type 1 Sand)
750 GPD / 0.8 gal/SF = 937.5 SF infiltrative area
937.5 SF x 1.2 (gravity, bed) x 1.0 (no reduction for chambers) = 1125 SF
In summary, the system appears to be sized to accommodate a 5-bedroom residence with less than
6000 square feet of living area under current OWTS Regulations. We are using Soil Type 1 (Sand)
based on the fact that the design is a sand filter; however, no information on the depth of sand was
available in the permit or as-built drawing.
Recommendations:
• Locate distribution box and bring access to grade.
This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County
Environmental Health Department, or to the Building Department in conjunction with your Building Permit
Application. The following are links to the required OWTS Use Permit Application and Checklist.
Application: http://www.pitkincounty.com/DocumentCenter/Home/View/621
Application Checklist: http://www.pitkincounty.com/DocumentCenter/Home/View/620
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector’s expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11044ITC Exp. April 2018
0020.2018.POWU
View of septic tank lids clean out
0020.2018.POWU
Part of STA under stone patio Inspection port
View of wall below patio
Inspection port
0020.2018.POWU
0020.2018.POWU
0020.2018.POWU
0020.2018.POWU
0020.2018.POWU
Pitkin County Environmental ' " -alth Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel ID #: 2643-164-01-011
OWTS Use Permit #: I 0029.2012.powu
Date Issued: 08/17/2012
Issued By: Bryam Daugherty
Expiration Date: 08/17/2013
Owner(s): Terri Hart
Property Address: 111 S Little Texas
Legal Description:
Other System Components
Licensed Inspector: Carla Ostberg
Inspection Date(s): 8/9/12
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete 2 Compartment tank 2000 gallons
Secondary Treatment Unit N/A N/A
Absorption Area Sand filter bed w/chambers 1684 sq ft
Other System Components N/A N/A
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 98067 Date of Issuance: 10/7/1998 Date of Final Approval: 8/22/2000
of Bedrooms or fixtures served by OWTS: The system was designed to serve 4 bedrooms, office/loft room was not
considered a bedroom when permitted although it meets the definition of a bedroom because it is private and has
direct access to a full bath.
Operational Status: According to the inspector's observations, the system was functioning properly at the time of
inspection. The 2000 gallon tank was watertight and in good working condition with both inlet and outlet tees in place.
The tank was not easily accessible because risers were about a foot below grade. The tank flows to a distribution box
that was not accessible from grade to a sand filter bed with gravelless chambers. The absorption area did not show any
signs of failure and there was no standing liquid in the observation ports.
Inspector Recommendations: Install effluent filter and add risers to the tank to bring them to grade.
Department Recommendations: The department recommends making the distribution box accessible from grade.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
0020.2018.POWU
IN Pitkin County Environmental u-alth Department
Onsite Wastewater Treatment Sysiel4n (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5077
www.aspenpitkin.com/EHNR
Parcel ID #: 2643-164-01-011
OWTS Use Permit #: I 0010.2014.powu
Date Issued: 04/0 /2014
Issued By: Kurt Dahl
Expiration Date: 04/09/2015
Owner(s): Eric and IN4aggie Scheyer
Property Address: 111 S Little Texas
Legal Description:
Other System Components
Licensed Inspector: Carla Ostberg
Inspection Date(s): 04/03/ 14
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete 2 Compartment tank 2000 gallons
Secondary Treatment Unit N/A N/A
Absorption Area Sand filter bed w/chambers 1684 sq ft
Other System Components N/A N/A
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 98067 Date of Issuance: 10/7/1998 Date of Final Approval: 8/22/2000
of Bedrooms or fixtures served by OWTS: The system was designed to serve 4 bedrooms, office/loft room was not
considered a bedroom when permitted although it meets the definition of a bedroom because it is private and has
direct access to a full bath.
Operational Status: According to the inspector's observations, the system was functioning properly at the time of
inspection. The 2000 gallon tank was watertight and in good working condition with both inlet and outlet tees in place.
The absorption area did not show any signs of failure and there was no standing liquid in the observation ports.
Inspector Recommendations: Install effluent filter, if possible
Department Recommendations: Install an effluent filter, if possible and bring the distribution box access to grade.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
0020.2018.POWU
0020.2018.POWU
0020.2018.POWU
832‐R‐13‐002
0020.2018.POWU
0020.2018.POWU