HomeMy WebLinkAboutPitkin.EH.264327401002 (2017) ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT 76 Service Center Rd· Aspen, CO · 81611 Phone: 970.920.5070 Fax: 970.920.5374 Permit #: 0030.2017.POWT Parcel ID #: 2643-274-01-004 Permit Issued: NEW REPAIR REMODEL/ADDITION TANK ONLY FIELD ONLY AMENDMENT Owner(s): Pam E. Moore Property Address: 361 Sunnnyside Ln Legal Description: Size of Lot: 3.1 Acres Detached Accessory Unit: YES NO Size of Building: 11,690 ft2 Sq. Ft. Size of Accessory Unit: 1000 Sq. Ft. This system will serve 6 bedrooms in the main house, 2 bedrooms in the CDU, and an office Designed By: CTL Thompson Project #: GS06121.000-210 Dated: 12/4/17 Phone #: Mailing Address: PO Box 7699, Aspen, CO 81611 Fax #: Email Address: Perc Rate: 1.0 LTAR (sand) Profile Hole Depth: 8’ Depth to Groundwater or Bedrock:  8’ Minimum Tank Capacity: 3096 gallons Minimum Absorption Area: 1632 ft2 Permit Conditions: This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the specifications cited above. Changes must be approved by this Department and the engineer prior to construction. This system will consist of a 3250 gallon, 2 compartment tank to collect effluent from all 3 buildings. Cleanouts must be installed at least every 100 feet. The 3250 gallon tank will gravity flow to a 1000 gallon single compartment pump chamber. The pump chamber will pressure dose to an ADV (automatic distributing valve)to dose 2 unlined sand filters. Each sand filter will consist of 68 gravelless chambers (4x17) with 3’ of sand minimum below. Geogrid fabric will be placed between the sand and chambers. A pressurized 2” PVC pipe with 3/16” holes drilled every 4’, every 4th hole facing downward for drainage will be hung from the top of the chambers. A ball valve accessible from grade will be installed at the end of each line for testing and cleaning. Observation ports must be installed at each corner of each bed, beds must be separated by at least 6’. Beds must be at least 100’ from the unlined ditch. This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called for the final inspection with a minimum of 48 hours notice. Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS Regulation. This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the syst em by qualified personnel, in accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits. THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE. Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as-built" drawing must be submitted and approved by EH before final approval of the system will be issued. Issued By: Bryan Daugherty, REHS Date: 2/1/18 Expires: 2/1/19 Installer: License #: Reactivation Authorized by: EH Final Approval Issued By: Date: New Expiration Date: Jeffrey Pfirman Bryan Daugherty, REHS 9/9/19 Parcel ID# (available from the Pitkin County Assessor's Office 970-920-5160 or at: http://pitkinassessor.org/assessor/search.asp *Contact information must be provided for the owner signing this application. FOR OFFICE USE ONLY Lot: Block: Filing: Subdivision: Cell Phone: Size of Building (square feet):Number of Potential Bedrooms: Company: City, State, Zip: Business Phone: Email Address: Contact/Applicant Mailing Address: Date: Date: City, State, Zip: Job Number:Phone Number:Fax Number: Mailing Address: Lot Size (in acres): Email Address: City, State, Zip: Business Phone: Property Owner(s)*: Owner's Mailing Address: Home Phone: Primary Contact Person/Applicant (if not owner): Fax Number: Building Permit # (if applicable): ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION 76 Service Center Rd · Aspen, CO · 81611 Phone: 970.920.5070 Fax: 970.920.5438 Purpose of Permit: Property Address: Cost of System Repair or Remodel/Addition (approximate): Size of Accessory Unit (square feet): Number of Potential Bedrooms In or Fixture List for the Accessory Unit: Detached Accessory Unit? Water Source: Name of Community/Public Water System (if applicable): Engineering Firm: Applicant Signature: Received by EN/HR Staff:Fee & Receipt #:Date: Owner Signature (Required): EH/NR PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in a ll of the documents included in my application package. I acknowledge that EH/NR may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. I understand that no construction may be undertaken on an OWTS until an OWTS Construction Permit is issued. NEW REPAIR DUE TO FAILURE REMODEL/ADDITION PRIVATE WELL SURFACE WATER COMMUNITY/PUBLIC WATER SYSTEM FIELD ONLY TANK ONLY YES NO SPRING PLEASE CHECK EACH ITEM TO INDICATE COMPLETION Only one copy of each item is necessary. OWTS Construction Permit Application (completed) Site Plan All designs must be 1" to 20' in scale. Soil Testing Notification & Report (must be provided by a PE) Report must include percolation test results and the soil profile evaluation. Building Floor Plans Land Use Approvals & Other Relevant Permits & Approvals Electronic document emailed to before the date of the pre-application conference Recorded Site Plan that designates approved envelope(s) for development. Proof of Adequate Water Supply Public systems: Applicable Fee Tank Only: $523 There is an additional Administrative Fee of $175 for properties in the Town of Snowmass Village. A complete application package must be presented at the time of submittal for acceptance. To schedule a pre-application conference, please call 970-920-5070. Please Make Checks Payable To: Pitkin County Environmental Health Department Legal water supply must be demonstrated in accordance with Colorado water law and meet the requirements of the Pitkin County Land Use Code. OWTS Construction Permit: $1,023 Proof generally includes a well driller's report, well permit issued by the Colorado Division of Water Resources, final augmentation plan (if required), and a recent pumping report. Wells must be drilled before an application will be accepted. Proof generally includes a letter from the CWQCD - approved public water system confirming it has sufficient water to supply the development and it has agreed to do so. ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) CONSTRUCTION PERMIT APPLICATION CHECKLIST 76 Service Center Rd · Aspen, CO · 81611 Phone: 970.920.5070 Fax: 970.920.5374 Private systems: Submit electronically to before the date of the pre-application conference. Comments from EH/NR regarding Land Use review referrals can be accessed by opening http://pitkincounty.com/454/Online-Search and choose "Planning", enter address, parcel or owner information to search. Referral comments more than 2 years old may need to be requested from the County Planning Department. Site plan must include locations of existing wells, buildings, property lines, ditches, water lines, springs, irrigation lines, drinking water cisterns, drain tiles, water bodies, wetlands, riparian areas, floodplains, dry gulches, and existing OWTSs. Copies of all land use approvals, as well as all other documentation relevant to the siting of the OWTS(s) and any other development on the property (e.g., Resolutions, Administrative Decisions, recorded easements). This Department should be notified when soil tests are conducted. A 2"- 4" perforated PVC pipe should be placed in the soil profile hole for monitoring purposes. If the property is exempt from this requirement, please have a Community Development Planner email with confirmation of the exemption. Electronic document emailed to before the date of the pre-application conference EH ENVIRONMENTAL HEALTH CHECKLIST (for approval prior to receiving a building permit) If any of the items below apply to your development, please make an appointment one of the Environmental Health professionals at 970-920-5070 or ehnr@co.pitkin.co.us to avoid delays in obtaining your building permit. The Environmental Health Department keeps files of permitted onsite wastewater treatment systems (OWTS) and can provide you with information pertaining to your parcel. If you have any questions concerning the last two items please contact the Planning Engineer (970-429-2799).  The new construction (including an addition/remodel) will require an onsite wastewater treatment system (OWTS), or require the addition of capacity to an existing OWTS. In this case, an OWTS permit must be obtained prior to issuance of a building permit.  The addition/remodel will use an existing OWTS. If the existing system is sized appropriately and the valuation of the addition/remodel exceeds $30,000, an OWTS use permit must be obtained prior to issuance of a building permit.  There are other OWTSs on the property, although none of those systems will serve the new development. These systems must obtain an OWTS use permit prior to the issuance of any OWTS permit or building permit.  The project involves a food service establishment (e.g., grocery or restaurant). Environmental health staff will need to review any new construction or modifications to assure compliance with the Colorado Retail Food Establishment Rules and Regulations. These regulations can be found at http://www.cdphe.state.co.us/op/regs/consumer/101019retailfood.pdf.  The project involves a childcare facility. In this case, EH/NR staff will need to review any new construction or modifications to assure compliance with the State Board of Health’s Rules and Regulations Governing the Health and Sanitation of Child Care Facilities. These regulations can be found at http://www.cdphe.state.co.us/op/regs/consumer/101007childcarecentersanitarystandards.pdf.  The property is located on the Smuggler Superfund Site and you will be moving more than one cubic yard of soil. In this case, you will need to complete a Smuggler Mountain Superfund Site Soil Removal Permit. See http://www.aspenpitkin.com/pdfs/depts/12/SMUGGLER_dirt.pdf.  You will be importing soil to the jobsite from the Smuggler Superfund Site, an old mining site, or a site that previously housed junked vehicles, oil or gasoline tanks, or other chemicals. More information, including regulations, applications, checklists, and other documents can be found at www.aspenpitkin.com/ehnr. Property Owner’s Name: ________________________________________________________ Property Address: _____________________________________________________________ Contact Name: ________________________________________________________________ Contact Numbers: (w) __________________________ (c) _____________________________ May 4, 2017 Richard Wax and Associates P.O. Box 7699 Aspen, CO 81612 Attention: Jeff Davis Subject: Soil Evaluation and Preliminary OWTS Design 357/361 Sunnyside Lane Legal Description: Lot B, Moore Exemption Assessor's Parcel Number: 264327401002 Pitkin County, Colorado Project No. GS06121.000-210 As requested, we have prepared this soil evaluation report and preliminary on -site wastewater treatment system (OWTS) design for the proposed residence at 357/361 Sunnyside Lane. The soil evaluation is required by the Pitkin County Environmental Health and Natural Resources Department (PCEHNRD) to char- acterize subsurface conditions where on OWTS will service a residence. Prelimi- nary design recommendations and site layout for OWTS components are in- cluded with this report. This report should be presented to the PCEHNRD with the application for the septic permit. Proposed Construction New construction at the site will consist of an approximately 12,000 square foot 6-bedroom main residence, a 2-bedroom guest house, and an office building. The office building will have a bathroom with a toilet, sink and possibly a shower. Potable water will be supplied by the White Horse Springs Metro Dis- trict. The existing well on the site will be abandoned. Proposed waterline loca- tions are not known at this time. Wastewater will be managed by a single OWTS, serving the three buildings. Site Description On March 9, 2017, a site evaluation was conducted by Edward R. White, P.E., CTL I Thompson, Inc. The 3±-acre parcel is located approximately 2 miles 234 Center Drive I Glenwood Springs, Colorado 81601 Telephom 970-945-2809 Fax: 970-945-7411 au■ northwest of Aspen. A vicinity map is presented as Figure 1. An aerial photo- graph of the site is shown on Figure 2. At this writing, two single-family resi- dences and a garage are located on the property. An irrigation ditch borders the site on the east. The proposed area for the OWTS slopes down to the west on the order of 10 to 12 percent. The landscape position of the test site is desig- nated LC, pursuant to the EPA's Onslte Wastewater Treatment Systems Manual. The only features requiring minimum setback distances from the proposed OWTS, as defined by Table 6.28-1 of the PCEHNRD OWTS Regulations are shown on Figure 2. These were observed during our preliminary investigation, reconnaissance, or soil investigation. The existing well on the site will be re- moved. The existing OWTS that currently services the two residences, will be abandoned and removed. Ground cover at the proposed soil treatment area (STA) consisted of natural grasses and weeds. Subsurface Conditions Subsurface conditions pertinent to OWTS design were investigated by ob- serving the excavation of two profile pits. The pits were excavated to depths of 8 feet with a backhoe. Subsurface conditions exposed in TP-1 consisted of ap- proximately 1-foot of topsoil and 1.5 feet of clayey sand underlain by clayey to silty gravel to the depth explored. Subsurface conditions exposed in TP-2 con- sisted of approximately 1 foot of topsoil and 1.5 feet of clayey sand underlain by clayey to silty gravel. Graphic logs of our profile pits are shown on Figure 5. Groundwater was not encountered in our profile pits. The loamy sand classified as Soil Type 1. The gravel soil contained more than 40 percent rocks and classi- fied as Soil Type 0, based on Table 6.28-7 in "Soil Treatment Area Long Term Acceptance Rates" by Soil Texture in the PCEHNRD regulations for OWTS. Gradation and hydrometer test results of bulk samples from our profile pits are shown on Figure 6. Subsequent to excavation of our profile pits, we were informed by the cli- ent that the proposed area of the Soil Treatment Area (STA) was moved. Infor- mation from exploratory borings drilled at the site for a separate geotechnical in- vestigation indicates that subsurface conditions are similar across the site. Prior to finalizing our OWTS design, we will observe the excavation of two additional profile pits adjacent to the revised STA location, pursuant to PCEHNRD require- ments. Recommendations Pursuant to PCEHNRD criteria, the subsurface conditions at the site are not appropriate for a conventional OWTS. A professional engineer must design the OWTS where a conventional system is not suitable. In our opinion, a mounded sand filter OWTS is appropriate for the site. The minimum STA size for the mounded sand filter should consider a loading rate no faster than 1.0 RICHARD WAX AND ASSOCIATES 2 3671361 SUNNYSIDE LANE PROJECT NO. GS06121.000-210 C:1tl5ers4cdowning%Box\ProjectsLGienwood Springs - Projects5GS06121.000521053. Letters=06121.000 210 L1.docx gal/ft2/day of residential strength wastewater. The average design wastewater flow for a 12,000 square foot, 6-bedroom residence is estimated at 1,200 gallons per day (gpd) as calculated from the equation on page 39 of the OWTS regula- tions. The design flow for a 2-bedroom residence is estimated at 300 gpd. The flow for the office is estimated at 48 gpd. The estimated total design flow for the OWTS is 1,548 gpd. Our STA recommendations are based on the following crite- ria and formulae: Treatment Level 1 (TL1) — Conventional Two -Stage Septic Tank/Mounded Sand Filter Adjustment Factor for Pressure Dosed Beds (from Table 6.28-8) = 1.0 Minimum Absorption Area = (1,548 gpd 11.0 gpd/ft2) x 1.0 = 1,548 ft2 Minimum Number of Infiltrator Standard. Quick4 Chambers = 129 Recommended Minimum Area = 1,584 ft2 (132 chambers) Wastewater is assumed to be typical residential strength. A minimum sep- tic tank capacity of 2,400 gallons is required to provide adequate detention time for the main residence (Table 6.28-6). A minimum tank capacity of 1,000 gallons is required for the guest house, and a minimum tank capacity of 400 gallons is required for the office. We recommend the use of two 1,250 gallon septic tanks for the main residence, one 1,000 gallon septic tank for the guest house, and one 500 gallon septic tank for the office building to provide the necessary storage vol- ume. We should be informed if future activities are planned that could result in higher than anticipated of flow or strength of wastewater. Our preliminary pro- posed locations of OWTS components (based on the clients revised STA loca- tion) are shown on Figure 7. Septic Tank Depths There are several issues that can affect the depth of septic tank installa- tion, which the owner and installer should discuss before the final installation ele- vation is selected. Building elevations and grading and sewer plans were not de- termined at this writing. Gravity flow from the house to the septic tank will depend on the configuration of the proposed structure and site grading. In addition, some county septic tank requirements preclude deeply installed tanks. The three tanks for this site should be installed with at least 4 feet of soils cover between the top of the tanks and the finished ground surface. Typical residential construction often provides adequate gravity flow from the upper floor levels, but not basement level areas. Sewage from lower floor lev- els might require the installation of an ejector pump in order to convey sewage to RICHARD WAX AND ASSOCIATES 3 357/361 SUNNYSIDE LANE PROJECT NO. G$06121.000.210 C:1Userslcdowning%BoxlProjectsS6lonwood Springs - Projects5GS06121.00058 M. LBtterslGS06121.000 210 Li.docx the septic tank. To minimize the load on the ejector pump, sewer plumbing can be split to allow the upper floors to drain by gravity to the septic tank. Installation Observations PCEHNRD should be given proper notice to observe the OWTS prior to backfilling and other specified stages of construction. CTL I Thompson, Inc. should be called to observe various stages of construction, from open excavation to the completed system to verify substantial compliance. Installation observa- tions are not included in the cost of this study and would be billed as authorized by a separate service agreement. Maintenance and Operation The OWTS requires conscientious maintenance and operation to provide a reasonable service life. The owner must consider that the OWTS does not have the same "unlimited" capacity as a municipal sewer system. An OWTS is sized for a limited hydraulic loading. Exceeding the design loading on a continual basis can harm the system and cause severe damage. Septic tanks should be checked periodically for scum and sludge accumulation and pumped as neces- sary. Limitations Accepted industry standards, methods and state and/or county guidelines were used to conduct this investigation and to develop this preliminary design. In some cases, actual flows and characteristics may vary substantially from typical estimates. Variations of subsurface conditions from those exposed in our profile pits may exist. An installer that is experienced and approved by the PCEHNRD is recom- mended for the installation of the OWTS. Due to variables, such as, but not lim- ited to construction methods, individual usage, maintenance habits, soil hetero- geneity and climate, no warranty expressed or implied as to the longevity or per- formance of the OWTS is made. We encourage owners of OWTS to visit www.nsfc.wvu.edu for additional resources for literature about OWTS. Due to the changing nature of onsite wastewater engineering standards and practices, the information and recommendations provided in this report are only valid for two years following the date of issue. Following that time, our office should be contacted to provide any updated recommendations and design crite- ria as appropriate. RICHARD WAX AND ASSOCIATES 4 357/361 SUNNYSIDE LANE PROJECT NO. G806121.000-210 C:SUserslcdowning16ox1Projects/Glenwood Springs - ProJects1GS06121.000521013. Letters%GS06121.000 210 Li.docx We appreciate the opportunity to work with you on this project. If you have questions or we can be of further service, please call. Very truly Yours�t 7 l> CTL I T jOL�INC:•` Edward R. WhiJ-i�•..P E` Project Engineer '-';;"r- viewed by: J es D. Kellogg, v sion Manager ERW:JDK:cd cc: Via email to jeffdavis(a�rwas�en.com coghlanv@gmail.com RICHARD WAX AND ASSOCIATES 5 3571361 SUNNYSIDE LANE PROJECT NO. GS06121.000.210 C:1UserslcdowningYBoxlProfectsSGlenwood Springs - Projects%GS06121.000121013. Letters1GS06121.000 210 Li.docx ;-m SCALE: 1 " = 2,000' Richard Wax and Associates 357/361 Sunnyslde Lane Project No. GS06121.000-210 Vicinity Map Fig. 1 SCALE: Lonamons and Profile Pit Locations Richard Wax and Associates 357/361 Sunnyalde Lane Project No. GS06121.000-210 Pig• 3 SCALE: 1 ° = 100' LEGEND: TPi1 APPROXIMAT OF PROFILE Proposed Construction and Profile Pit Locations Richard Wax and Associates 357/361 Sunnyslde Lane Project No. GS06121.000-210 Fig. 4 TP-1 El. 7913 ,915 Fr7,910 w w w z O w w f -7,905 7,900 RICHARD WAX & ASSOCIATES, LLC 357/361 SUVNYSIDE LANE PROJECT NO. GSD6121.000-210 T El. 791 7915 LEGEND: FF 7,915 TOPSOIL, ORGANICS, MOIST, BROWN. LOAMY SAND, MOIST, BROWN, SINGLE GRAIN, STRUCTURE, SOIL TYPE 1. 7,910 w GRAVEL, > 40% ROCKS, BROWN, RUST, MOIST, GRAIN STRUCTURE, SOIL TYPE 0. AnSINGLE O BULK SAMPLE OF SUBSOIL OBTAINED. 7,905 w NOTES: 1. EXPLORATORY PITS WERE EXCAVATED ON MARCH 9, 2017 WITH A BACKHOE. 2. LOCATIONS AND ELEVATIONS OF 7,900 EXPLORATORY PITS ARE APPROXIMATE, 3. NO FREE GROUNWATER WAS FOUND IN EXPLORATORY PITS AT THE TIME OF EXCAVATION. 4. EXPLORATORY PITS ARE SUBJECT TO THE EXPLANATIONS, LIMITATIONS AND CONCLUSIONS AS CONTAINED IN THIS REPORT. 4. SOIL EVALUATION CONDUCTED BY EDWARD R. WHITE, P.E. (CPOW SOILS CLASS CERTIFIED). Summary Logs of Exploratory Pits FIG. 5 .1 ,■ 11 1 •1 . 1 1 •, �����www^iiiwwww�awww��a�lwww..��.�wr• rr• � �� �r!!i 1■��lr�w�www�i� w� � ww� ww/ wwww� ww�wwlw•.rww�ii /�iiwwa■111r.�ii�� �wwM wwww-��liiwawwli!'il��rw�w� wwww��www��ii awww��i�w'iww�w�� wwwwl� w� www!-ww� ww� wwwtii l��lwwaa-�ia���w� l����!li��aww�rrw� r!!�law�rwlw� / wrr w �. 1 II � �� www� � i i!�! i rr•ii r�l ��� � � �ww� � wwaa! i r/•��i! wwwa'i ■Iw•a� s�sa � { wwwa��r.rwww��ir�wa��ww�wwwa�i+ll��w.�w� wwww � /PI/rlaw�' iiirl�li ��i �! � ism � �In/A—>• � rrr�r _w rlwirr� ���1^��iwwwrl����l�lwwwai���^>—a� ��r_w/��ir�■liwwww�wwlwr�i�����:—ram w.����i�^i�����l�ilw��w�■��a� w� • 1 1 rwrrwlww��www� ���www�'irwwwlil�lrrrwi^���la� rrww i www^l��r,w�w�rwwwa! wwww��^� � -� �� ■1 1 FI �-w- Wit! � � ��� .�1-1! 1 11 11 1■• 1 1 1 •1 1 /1 STIC) TO SILT (NON -PLASTIC) ■ Sample of GRAVEL, CLAYEY TO SILTY (GC -GM) GRAVEL 43 % SAND 36 % From TP - 1 AT 5-7 FEET SILT & CLAY 21 % LIQUID LIMIT % PLASTICITY INDEX % ■ VERMIN■. •1 11 11 1 1 ■ 1 i�w���i!!�1•l�r � �r✓� � i!!ii �! � ll�r�r� irk � � �r � �_ !� �� � i!lrwsi maw � irk � �r•I�w � i-�� �i!lrww•i�A�i! ��r�w !-� � �!!!�i•il�il��s�w� 1 i-���!!liil�il���=� ■ i� �aww��iil�wwlwwww w� li�� �!� i�w�www�� ii! ��lwwwwr�Rliw��� awww � -{ i-r���lil��l�rrr!lir��wwwr� 1 i-rr���!!i!law�il��wwwr� i����!li��i �w�■1llii�'www r� i i��w���■lir:wwiw�w �w��/�1lir��iwwww�wi■ii�■ll�wwwr� � ii� wwwwlwwwr� ����■[r—w�i��iww���lawww�Alww��Iw��awM :{ wm limit r� i!!i! i �!! � ww� ! = ==� � •/ wl��iA-1��■�1�1■��l�l�w�lAilrllf11�17•!fr'w!■IA�r� 1 ■ 1 1 1 ■ • i1 Sample of From GRAVEL % SAND o SILT & CLAY 30 % LIQUID LIMiT % PLASTICITY INDEX % Richard Wax and Associates, LLC Gradation 357i361 Sunnyside Lane PROJECT NO. GS06121.000 210 Test Results FIG. 6 APPROXIMATE LOCATION OF,. PROPOSED STA W' `4 100' SETBACK c ?� � t -..FROM DITCH SCALD: 1" = 40f t�VSEPTIC TANK 4 1e 1 PUMP TANK �i g r 4 x tn ` 1 �yit z� 1 � r. � �i S�L"L `a/ l - 4' ] 4•L 11. ® ] ,? -.' '• !�y't1 i 1 I I\\ n din w� t - &° . 1 `" VNJ ` SEPTIC TANK �Ia', , PUMP. TANKff 08�a. gal 1 .� EP,56 cd; wt. 1 • � ' 1 l tt �` � PUMP TANK 0c IJ \ Atp SEPTIC TANKS 1 W , 1 �_7z Wi -850 1 _ ` 1 4V r L , 1 _ �• � , M g� ' �1 .Proposed Location 1 \1 o of Onsite W Wastewater 0 Treatment System �I Components Richard Wax and Associates 35V361 Sunnystde Lane N Fig. 7 Project No. GS06121.000-210 1 N C O R P O R A T i 0 July 26, 2019 (Revised September 3, 2019) Richard Wax and Associates P.O. Box 7699 Aspen, CO 81612 Attention: Jeff Davis Subject: Installation Observations for Onsite Wastewater Treatment System 357/361 Sunnyside Lane Pitkin County, Colorado Project No. GS06121.000-210 As requested, CTLIThompson, Inc. visited the subject site to make obser- vations of the installation process for the Onsite Wastewater Treatment System (OWTS) for the residence, a guest house, and office building at 357/361 Sunny- side Lane in Pitkin County, Colorado. The Pitkin County Environmental Health Department (PCEHD) requires observations by the designer of the OWTS. We designed the OWTS for the 6-bedroom residence, 2-bedroom guest house, and an office building with a bathroom using an average design load of 1,548 gallons per day. The system includes two septic tanks to achieve the required 3,250- gallon septic tank design volume, a 1,000-gallon pump tank, and an Automatic Distributing Valve (ADV). The ADV distributes the flow to two 68 feet by 12 feet unlined sand filter beds, each consisting of 68 Quick4 Chambers. We visited the site on June 19 and 22, 2018 to observe the STA prior to backfilling. During our June 19 site visit, we observed the excavation of the STA prior to placing the sand for the unlined sand filter. Subsurface conditions were as expected from our profile pits for the OWTS design. At our June 22 site visit, we observed the installed sand, geogrid, chambers, and observation pipes. Based on our observations, the STA was installed in general conformance with our design. On July 22, 2019, we made a subsequent visit to the site. We observed an installed, single -compartment 2,000-gallon septic tank in series with a single - compartment 1,250-gallon septic tank with effluent filter, a 1,000-gallon pump tank, transport effluent line, ADV, and cleanouts. The tanks, ADV, and cleanouts 234 Center Drive I Glenwood Springs, Colorado 81601 Telephone:970-945-2809 Fax:970-945-7411 were observed after backfilling. We requested photos of the installation of the tanks to observe that components were installed properly. Additionally, we re- quested the parts list from the septic component supplier, so that we could verify the proper components were installed. The contractor had installed an alarm to indicate pump failure and intends to wire the alarm to inside the house. Our ob- servations and the photos/parts lists provided by the client indicate that the OWTS components were installed in general conformance with our design. Fig- ure 1 shows the locations of the installed components. If you have questions regarding the information provided in this letter, please contact us. We appreciate the opportunity to work with you on this project. Very Truly Yours CTL I THOMPSgN # ,' 42809` m'. " Edward R\'VVbite, P.E. Project Engiheer;�J•...•�-��;.' ERW:JDK Reviewed by: ,J-_ I - \ �' f r J mes D. Kellogg, P.E. D ision Manager cc: Via email to jeffdavis(c�rwaspen.com, coghlanv(a)-gmail.com RICHARD WAX AND ASSOCIATES 357/361 SUNNYSIDE LANE PROJECT NO. GS06121.000-210 C:lUsersltwhitelAppDatalLocallBoxlBox EditlDocuments1wR82QTtnek6SZNHkj_dFbg==1GS06121.000 210 L4 (Revised).docx F r1Fx�.cL- 1 w. w/1.25in. RED PLASTIC '643-274-01-001 CAP LS33638 ' S00030'15"W 66.70' 2643-274-0�-002 IS 00°37'06" W 66.66') / rye / S 1 2°59'03" E 33.0 1' FOUND No.5 REBAR FOUND No.5 REBAR (S 1 2°51 '56" E 33.06') G49' BENT o 66` FOUND No.5 REBAR FOUND No.5 REBAR 9 / A <v^ 32 SUNNYSIDE WAY (S 19012'33" E_ 124.22') w/1.25in. RED PLASTIC SCALE: y" = 40' is ° �'S S 19 °26' 14" E _t 24.34'_ CAP LS 33638 SET Na.S REBAR wl2in. 3 1 -STORY HOUSE j (S 0 7 o _ _ ALLOY CAP LS R23875 w0 / 1 026 SQ.FT. +_ f \ S 0-- 48" ADS --\ °O 2 W.C. 5fl. SE 60" CMP \/ -... - INV OUT:7935.37 `'�6E _ - _ 1 9,�- �� - INV IN:7935.24 -/\ _. / �_-.. - - - .. I \ _ �. I 48" ADS F S 5" E OQ' - �INV OUT:7935.45 69. 32� 1 , E 0 -- - r, 2 48" ADS INV IN:7935.45 rJ 32 - - _ - V INV IN'79355..866 �1 J �- / w - ' / 181.3 W v� L , 0 - 2 A/C UNITS - A_ % `I I T r 40.6' .I ON PAD Rid5. CALL BOX OTTOM WINDOW - CA B K ' 1 -/ - _- WELL:7927.99 _ PARKING - -®� f - -- - j ��27.8\-m _ - - � HOT -V /� ♦ TUB_ i f � \ � � fW0 \ l 1 - , I I � � �- J f 1 � oDs s' �� .' p'J� ' PARKING CANTERPATIO �` TREE P (TYP�) ' �� GARAGE 15.2 SUNNY _ - SIDE WAY J ,a`� 838' OVER ADS _ PYLIGHT:7923.68 """ ADS O. (� I I - w 2. 9Q�� DAYLIGHT:7922.53 Ir� O N N _ PARKING J \ \ I � 7 SUNNYSIDE WAY ^5' � I,1 w ORENCO V6402A AUTOMATIC \ v 0 5s.4' 292. ..;.� ® 1-STORYHOUSE D LIGHT:792 DISTRIBUTING WINDOW G 51 6 SQ.FT. + - G VALVE ss7 ln�-116.9' 20 � . _ _ .- -...I- - fir, 19 Z,. ' , / �\ / 3 C UNITS %-� _ - 0� I, w , .,2.9. ON PAD s 1A ,5.. ® \ 0•I I HVAC - o .- I BOTTOM o 26.3` �� -I-......I �� I WINDOW // -"� ©©®®a©�®o -- '�_._ v / \ rn s _ 50' SETBACK Z Cfl I I w - I-- I WELL:7923.69 61 SUNNYSIDE WAY MULTI -STORY HOUSE Z I'-m I 3 - -- - --- 2 CONDUIT 6 "ADS o ..I I - -Z iv - _ �� -- -- _ ORISER INVIN:922.06 /...,IV 8,092SQ.FT.± ^p,. ,p -� - 'i�i��/i��i,. I 5 - I I - - _. J _ _ _ \ : �j� / PLANTER 26" LID TYP. ss l N - o . - . - . ' ( ) _ M 27.5 1 14.4 c.i POND i 0 _..I -I _ -- -- -.Q / = - 1< l 1 i _ I 22.3- - PLANTER - '> - LI �� 4ENT M15. - - - G. 75 ,1 5 z- ive 4" PVC LEACH FI (TYP.)J � J � -. - -� _ ) ive ©� i _ ;.I �__ z ss H T TUB N iJ I NT I7'5' I w unurr/ -/ 4"PvcDAYUGHT _ ' _Q _, 2,000-GALLON AND 1,250-GALLON SEPTIC TANKS 75 - -- _m ENVELO E - - INVOUT:7916.05 _ -- ACRE W AND 1,000-GALLON PUMP TANK - - C� E�� LOCATION OF INSTALLED STA - _ u° 3s"uo(TYP.)Ss �I- (30 X 68 FOR TWO 12 BEDS WITH -------- ---- -- ------=-------- --_ =-- 19-14' > OF UNDISTURBED SOIL BETWEEN BEDS) \ ---- -- - _--------� -- -- © 6 - -- - - z - _-57J.93' - - (N 21 °51'00" W_�� E / / 580.00') I SPIGOT DAYLIGHT:7909.34 \-36D CMP 2" PVC 4" PVC 8" PVC LI LID:7915,01 01 3" PVC DAYLIGHT:7910.20 DAYLIGHT:7908.54 DAYLIGHT:7915.45 DAYUGHT:7914.27 6" PVC 275 SUNNYSIDE LN. DAYUGHT:7915.82 NOTE: PLAN IS FROM IMPROVEMENT SURVEY PLAT PROVIDED BY HIGH COUNTRY ENGINEERING, DATED AUGUST 13, 2019. Richard Wax and Associates 357/361 Sunnyslde Lane Project No. GS06121.000-210 Installed Locations of Onsite Wastewater Treatment System Components Fig. 1