HomeMy WebLinkAboutPitkin.EH.264322301004 (2019)
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd· Aspen, CO · 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0033.2019.POWT Parcel ID #: 2643-223-01-004
Permit Issued: NEW REPAIR REMODEL/ADDITION TANK ONLY FIELD ONLY AMENDMENT
Owner(s): Mike Marolt
Property Address: 59 Stevens St
Legal Description:
Size of Lot: .50 Acres Detached Accessory Unit: YES NO
Size of Building: 2297 Sq. Ft. Size of Accessory
Unit:
Sq. Ft.
This system is designed to serve 4 bedrooms
Designed By: CBO Septic Consulting Project #: C1474 Dated: 10/4/19
Phone #: 970-309-5259 Mailing Address:
Fax #: Email Address: Carla.Ostberg@gmail.com
Perc Rate: .60 LTAR Profile Hole Depth: 7’ Depth to Groundwater or
Bedrock: 7’
Minimum Tank Capacity: 1250 gallons Minimum Absorption
Area:
840 ft2
Permit Conditions:
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the
specifications cited above. Changes must be approved by this Department and the engineer prior to construction.
The existing OWTS system is being replaced. The existing tank must be pumped prior to being removed or crushed in
place. The new system will consist of a 1500 gallon, 2-compartment tank, with an effluent filter in the outlet tee. Risers
must be accessible from grade. Effluent will gravity flow to a distribution box to split effluent to 2 gravelless camber bed s.
Each bed will consist of 36 chambers each (4x9 and 3x12). Observation ports must be installed at each corner of each
bed. Absorption beds must be separated by at least 6 feet and must be at least 10 feet from the home.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as-built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called
for the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of
this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is
hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS
Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system ha s commenced.
An "as-built" drawing must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Bryan Daugherty, REHS Date: 10/30/19 Expires: 10/30/20
Installer: License #: Reactivation Authorized by:
Final Approval Issued By: Date: New Expiration Date:
EH
Bryan Daugherty, REHS 2/19/20
Altitude Septic, LLC 52
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
February 16, 2020 Project No. C1474
W/J Metropolitan District
c/o Ben Elmore
belmore@za-engineering.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
59 & 61 Stevens Street
Pitkin County, Colorado
OWTS Construction Permit 0033.2019.POWT
Ben,
CBO, Inc. observed the installation of the onsite wastewater treatment system (OWTS) on November 20,
2019 for the subject property. Altitude Septic installed the system.
The OWTS design was based on a 4-bedroom residence. A design flow of 600 GPD was being used.
The existing septic tank was pumped and the top, sides, and bottom of the tank collapsed, and the void
filled with on-site soils. The existing STA was abandoned in place. The sewer line from the residence to
the existing septic tank was recently replaced. The existing sewer line remained and a double-sweep
clean out was installed on the existing sewer line just before the new septic tank.
The installation included a new 1500-gallon, two-compartment poly Infiltrator® septic tank with an
Orenco® Biotube Effluent filter on the outlet. This filter must be cleaned annually, or as needed.
Effluent gravity flows to a distribution box, which was accessible from grade. Flow equalizers were
installed to assure equal flow to each bed. The STA consists of two beds (Bed A and Bed B). Bed A has
4 rows of 9 ‘Quick 4’ Low Profile Infiltrator® chambers for a total of 36 chambers and 432 square feet of
infiltrative area. Bed B has 3 rows of 12 ‘Quick 4’ Low Profile Infiltrator® chambers for a total of 36
chambers and 432 square feet of infiltrative area. There was at least 6-feet of undisturbed soil between
the beds. Inspection ports were installed in each corner of both beds. Ports may be cut to grade and
placed in sprinkler boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS:
Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent of the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
Splash guards installed on end caps Bed A
Bed A Bed B
Existing tank being pumped new cleanout installed
Inlet tee, new tank
New septic tank installed effluent filter
Distribution box
Distribution box, set on gravel base Pipes from distribution box to STAs
Manifolds for both Beds A and B
View of pipe from tank to distribution box Distribution box at grade after backfill
Chambers set in Bed A over-ex for Bed B
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd· Aspen, CO · 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0033.2019.POWT Parcel ID #: 2643-223-01-004
Permit Issued: NEW REPAIR REMODEL/ADDITION TANK ONLY FIELD ONLY AMENDMENT
Owner(s): Mike Marolt
Property Address: 59 Stevens St
Legal Description:
Size of Lot: .50 Acres Detached Accessory Unit: YES NO
Size of Building: 2297 Sq. Ft. Size of Accessory
Unit:
Sq. Ft.
This system is designed to serve 4 bedrooms
Designed By: CBO Septic Consulting Project #: C1474 Dated: 10/4/19
Phone #: 970-309-5259 Mailing Address:
Fax #: Email Address: Carla.Ostberg@gmail.com
Perc Rate: .60 LTAR Profile Hole Depth: 7’ Depth to Groundwater or
Bedrock: 7’
Minimum Tank Capacity: 1250 gallons Minimum Absorption
Area:
840 ft2
Permit Conditions:
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the
specifications cited above. Changes must be approved by this Department and the engineer prior to construction.
The existing OWTS system is being replaced. The existing tank must be pumped prior to being removed or crushed in
place. The new system will consist of a 1500 gallon, 2-compartment tank, with an effluent filter in the outlet tee. Risers
must be accessible from grade. Effluent will gravity flow to a distribution box to split effluent to 2 gravelless camber bed s.
Each bed will consist of 36 chambers each (4x9 and 3x12). Observation ports must be installed at each corner of each
bed. Absorption beds must be separated by at least 6 feet and must be at least 10 feet from the home.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as-built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called
for the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the system by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of
this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is
hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS
Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system ha s commenced.
An "as-built" drawing must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Bryan Daugherty, REHS Date: 10/30/19 Expires: 10/30/20
Installer: License #: Reactivation Authorized by:
Final Approval Issued By: Date: New Expiration Date:
EH
832‐R‐13‐002
n C7 W C7
�� W O]
v 0 a -n o
O (D 0 0 7
� c- o
s 4 v
(o W (D CCD
V (O 0
(a un N o p o
�
-. 0
a(D �
CO
(7 O X
3 CO v =
N Q�
W
�• �
CD Q° O
1 rf
c c Cn
� < CD
n �
n oQ
cn m
1 � �
4�1 O (_D 0
m
000
�y
CD
1
o
p
W
0
�ZD
A7 Z Z
D�(n
m0�
p CZ C
D
p W
4�,=m
(.0 m Cn
Cl) m
G) p
zz
0
0
m D Cn �
X Z C 2
n p ;u m
m 0
D -u -< 0
00M�
?mmo
K r Z
z00
D
X
0 Z
�C/)z
�D�
0 m z
z
Cn -0 p
�XX
D O -u
O
Cn
Imo
D � �
mFn;u
>0
r=m
�mK
co
0 O Cn
oz0
cn
z
zcn
D
ncm
m
Cn 0
2: 0
0
m
r-Zm
Wpm
m m Cn
0��
z r-
0
n
D
m O
p�0
o��
�0
oz�
..
Cn o
v
m
1 1
n
Cl)
0
W
O O
0
I CCD
DI
Ct) Cf)
--i -i m
I < m a I
I z o n ml
(n ZJ
C/) C/) <
r I
m m D m
CA m �
I < I
100 I
0mK
o
_ I
C
I c I
z
o
I I
I I
I I
N
O