Loading...
HomeMy WebLinkAboutPitkin.EH.264504303014 (2020)0016.2020.POWU 0016.2020.POWU 0016.2020.POWU Permit Receipt Date:Name: Project Address: 4/2/2020 Permit Number Fee Description Amount chargeType:# 130421906 RECEIPT NUMBER 00047270 116 KATYDID LN BRIAN FLYNN PITKIN COUNTY COMMUNITY DEVELOPMENT 0016.2020.POWU OWTS Use Permit Fee 100.00 0017.2020.POWU OWTS Use Permit Fee 100.00 200.00Total: 0016.2020.POWU For Review 04/01/2020 0016.2020.POWU For Review 04/01/2020 0016.2020.POWU For Review 04/01/2020 Clean out next to wood step behind aspen tree – all measurements from top of clean out 0016.2020.POWU For Review 04/01/2020 Tank Location Tank 1 – Two compartment in background 1000 gallons Tank 2 – single compartment pump chamber – 1000 gallons Pump piggy backed on float switch with high water alarm float 0016.2020.POWU For Review 04/01/2020 Primary on Tank 1 – inlet 0016.2020.POWU For Review 04/01/2020 Secondary on Tank 1 – outlet into pump tank 0016.2020.POWU For Review 04/01/2020 Pump and floats in Tank 2 – single compartment tank 0016.2020.POWU For Review 04/01/2020 Mound system – absorption area 0016.2020.POWU For Review 04/01/2020 0016.2020.POWU For Review 04/01/2020 0016.2020.POWU For Review 04/01/2020 0016.2020.POWU For Review 04/01/2020 Page | 1 Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 www.aspenpitkin.com/EHNR Parcel ID #: 2645-043-03-014 OWTS Use Permit #: 0016.2020.POWU Date Issued: 4/22/20 Issued By: Bryan Daugherty Expiration Date: 10/22/20 Owner(s): Bob Wirtz Property Address: 116 Katydid Lane Legal Description: Licensed Inspector: Brian Flynn Inspection Date(s): 3/13/20 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit 2 compartment concrete tank Pump Chamber 1000 gallons 1000 gallons Secondary Treatment Unit Absorption Area Mounded Bed 480 ft2 Other System Components Pump OWTS Use Status: In use at the time of the inspection. Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 92033 Date of Issuance: 7/6/92 Date of Final Approval: 7/7/92 # of Bedrooms or fixtures served by OWTS: System was designed to serve the 2 bedrooms. Operational Status: According to the observations of the inspector on site, the system appeared to be functioning as designed. The tanks were in watertight condition and pump with functional. The field area did not show signs of failure. Inspector Recommendations: N/A Department Recommendations: Continue maintenance as needed. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. 0016.2020.POWU For Review 04/01/2020