HomeMy WebLinkAboutPitkin.EH.264929400006 (2020)Page | 1
Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2649-294-00-006
OWTS Use Permit #: 0017.2020.POWU
Date Issued: 4/22/20
Issued By: Bryan Daugherty
Expiration Date: 10/22/20
Owner(s): Wallace Parker
Property Address: 134 Ute Trail
Legal Description:
Licensed Inspector: Brian Flynn
Inspection Date(s): 3/13/20
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit 2 compartment concrete tank 1250 gallons
Secondary Treatment Unit
Absorption Area Two Beds 1320 ft2
Other System Components
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 87060 Date of Issuance: 10/16/87 Date of Final Approval: 4/11/88
# of Bedrooms or fixtures served by OWTS: System was designed to serve the 3 bedrooms.
Operational Status: According to the inspectors observations on site the system appeared to be functioning as
designed. The water was accessible from grade and tees were in place. The field area did not show signs of failure.
Inspector Recommendations: N/A
Department Recommendations: Continue maintenance as needed. Add effleuent filter to outlet tee.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
0017.2020.POWU
Permit Receipt
Date:Name:
Project Address:
4/2/2020
Permit Number Fee Description Amount
chargeType:# 130421906
RECEIPT NUMBER 00047270
116 KATYDID LN
BRIAN FLYNN
PITKIN COUNTY COMMUNITY DEVELOPMENT
0016.2020.POWU OWTS Use Permit Fee 100.00
0017.2020.POWU OWTS Use Permit Fee 100.00
200.00Total:
Clean out under deck
0017.2020.POWU
Two reference point to the first lid
0017.2020.POWU
Location of tank, c/o in background
0017.2020.POWU
Primary side – concrete inlet baffle under lid
0017.2020.POWU
Secondary – outlet pipe
0017.2020.POWU
Absorption area
0017.2020.POWU