HomeMy WebLinkAboutPitkin.EH.246734301009 (2019)Page | 1
Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2467-343-01-009
OWTS Use Permit #: 0021.2019.POWU
Date Issued: 5/6/2019
Issued By: Bryan Daugherty
Expiration Date: 5/6/2020
Owner(s): Randy Rieger
Property Address: 167 Picket Pin Lane
Legal Description:
Licensed Inspector: Travor Dunsdon
Inspection Date(s):
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete two compartment tank
Concrete two compartment tank
1250 Gallons
1250 Gallons
Secondary Treatment Unit
Absorption Area Gravelless Chamber trenches 680 ft2
Other System Components
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 06070 Date of Issuance: 9/13/06 Date of Final Approval: 11/10/06
# of Bedrooms or fixtures served by OWTS: This system was designed to serve 4 bedrooms.
Operational Status: According to the inspector’s observations on site, the system appeared to be functioning as
designed. Both tanks with in good working condition with tees and baffles in place. The effluent filter was clogged but
was cleaned as part of the inspection. The field area did not show signs of failure such as surfacing effluent.
Inspector Recommendations: Pump first tank in series in the near future. Clean effluent filter yearly or as needed.
Department Recommendations: Continue maintenance as needed.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
5/6/2019 Pitkin County Mail - Online Form Submittal: Property Sale/Remodel Use Permit Application
https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632798502054008443&simpl=msg-f%3A16327985020…1/3
Bryan Daugherty <bryan.daugherty@pitkincounty.com>
Online Form Submittal: Property Sale/Remodel Use Permit Application
noreply@civicplus.com <noreply@civicplus.com>Mon, May 6, 2019 at 9:53 AM
To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com
Property Sale/Remodel Use Permit Application
Please Note: Each OWTS System must be submitted individually. If there are
additional systems on the property, additional applications are required.
Job Parcel ID 2467343010009
Physical Address 167 Picket Pin, Snowmass, CO 81654
Residences 1
No. of Bedrooms 4
Square Footage of each
Residence
3,265
Purpose of Use Permit Property Transaction
Closing Date 5/17/2019
Lot 1
Block 9
Filing 1
Subdivision Gateway of Snowmass Subdivision
(Section Break)
Primary Contact Information
Primary Contact First Name Thomas
Primary Contact Last Name Carr
Primary Contact Email
Address
tcarr@aspenreinfo.com
Primary Contact Address 555 E Durant, Suite 5a
Primary Contact Phone
Number
970 925-5400
Primary Contact City Aspen
Primary Contact State CO
5/6/2019 Pitkin County Mail - Online Form Submittal: Property Sale/Remodel Use Permit Application
https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632798502054008443&simpl=msg-f%3A16327985020…2/3
Primary Contact Zip 81611
(Section Break)
Owner Information
Primary Contact is Owner?No
Owner First Name Randy
Owner Last Name Rieger
Owner Email Address randyr@htgf.com
Owner Mailing Address 3255 Aviation Ave, Ste 602
Owner City Coconut Grove
Owner State FL
Owner Zip 33133
Owner Phone 305 799-8144
Owner Fax Field not completed.
Indicate Preferred Method of
Payment
Debit/Credit Card
Payment Contact Email for
Debit/Credit Payment
tcarr@aspenreinfo.com
(Section Break)
Licensed Inspector Information
Primary Contact is Licensed
Inspector?
No
Inspector First Name Travor
Inspector Last Name Dunsdon
Inspector Email Address altitudeseptic@gmail.com
Inspector Mailing Address PO Box 1534
Inspector City Eagle
Inspector State CO
Inspector Zip 81631
Inspector Phone Number 970 471-6292
Inspector Fax Number Field not completed.
(Section Break)
Uploads
Pitkin County Inspection 167 Picket Pin Lane - Permit Inspection.pdf
5/6/2019 Pitkin County Mail - Online Form Submittal: Property Sale/Remodel Use Permit Application
https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632798502054008443&simpl=msg-f%3A16327985020…3/3
Form
Site Plan NewILC-ReigerPropertyMarch2019.pdf
Floor Plans RiegerEnvironmentalHealthPlans.pdf
Additional Reports, etc.Field not completed.
Comments or additional
information:
Field not completed.
PLEASE READ BEFORE SELECTING SUBMIT:
By selecting SUBMIT, I certify that I am the owner or representative with the legal
authority to agree to the conditions of this permit, the above information is complete
and accurate, and that I have provided complete and accurate information in all of
the documents included in my application package. I acknowledge that this
department may revoke any permit I am issued if my application is found to contain
any inaccurate, false, or misleading information.
Building Permit Instructions
If this application is part of a building permit application, please bring a copy of this
application to your building Pre-Submittal meeting. To get a copy, either enter your
email address to receive a copy of your application, or select "Submit and Print"
below.
Email not displaying correctly? View it in your browser.
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
D� USE PERMIT INSPECTION FORM
76 Service Center Rd Aspen CO 81611
' 970-920-5070 Fax 970-920-5077
www.PitkinCounty.com
Inspection for Permit Number: POWU
Job Address (provide proof of application for an address if there is currently no address) _Address Application
ob street:
167
Picket Pin Lane Job
city:
Snowmass
Job
state:
CO Job zip
81654
Owner
Owner First Name: Randy
Owner Last Name:
Rieger
Owner Corporation Name:
N/A
Owner Mailing Address:
12,627
S. Bayshore Drive Apt 2 owner
city:
Miami
lowner State: FL
Owner Zip: 33133
Owner Phone: ( 005)
799-8144
Owner Cell Phone:
Owner Ema":Irandyr@htgf.com
Permit Contact
Contact First Name:
Om
Contact Last Name:
Carr
ontact Business Name:
Leverlch & Carr
Contact Mailing Address:
555
E. Durant, suite 5a Contact
City: [Aspen
Contact State: CO
Contact Zip:
81611
Contact Phone: (970)
925-5400
Contact Cell Phone:
(970) 379-9935
Contact Email:
cart@aspenreinfo.eom
Licensed Inspector
Inspector First Name:
ravor
Inspector Last Name:
Dunsdon
Inspector Business Name:
ltitude Septic
Inspector Mailing Address:
PO BOX 1 534 Inspector
City:
Eagle
Inspector State:
CO
Inspector Zip:
81631
Inspector Phone: (970)
471-6292 1
Inspector Cell Phone:
(970) 471-6292
1
Inspector Email:
altitudeseptic@gmail.com
Inspector's License Number:
53
Parcel ID
Z'� 6-7 -3Y.3
Legal Description
Lot 9, Block 1, Filing 1, Gateway of Snowmass Mesa Subdivision
A copy of this inspection will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the
inspection regardless of whether the system passes or fails.
Questions For Property Owner PRIOR To Inspection:
Is the home currently occupied? No
How many bedrooms are in the home?
If N: How long has it been vacant? 15-18 months
RECORD
Were system records available from Pitkin County? es
If Y: Permit Number 06070 Date of final approval: 11/10/06
Was an as -built drawing available? es
Is the as -built drawing accurate? es
If N: Complete and upload a drawing of the system as accurately and possible ❑
Describe change in use differences:
—
No. of bedrooms permitted:
SITE CONDITIONS
Any questions marked FAIL or NO will require correction before an OWTS Usc permit is issued.
Proper grading, no evidence of erosion: P-ASS-1 Proper vegetation cover: Fes M7
NO evidence of compaction such as heavy machinery or livestock: No
Proper discharges (no straight pipes): PASS NO evidence of high ground water: No
Snow cover is NOT present: No •
Site Conditions Pass/Fail: PASS
TANK(S) TANK TANK 2 TANK 3
Tank Capacity (gallons)
1250
1250
Tank Material
Concrete
Concrete
Number of compartments
2
2
Date of last pumping
Possibly 5-6'years
Lids/risers
PASS Lj
PASS E11FAIL
Risers to grade
YES •
ES 1-711NO
Riser height
3 feet on inlet and 2 feet on outlet
1.5 feet on inlet 1 foot on c
Riser condition/water tightness
Good condition
Good condition
Inlet Sanitary T/Baffle
PASS El
PASS 1_7AIFAIL
Outlet Sanitary T/Baffle
PASS •
iFASS
FAIL
Effluent Filter (if part of design)
PASS
N/A
INO
N/A
Condition of Tank Material
PASS •
PASS
FAIL
Tank was pumped for inspection
NO
NO
If Y: List Pumping Company
If N: Date of last pumping
Possibly 5-6 years
Scum level (1st compartment) inches
0
Sludge level (1st compartment) inches
8
Scum level 2nd compartment) inches
_
0
Sludge level 2nd compartment) inches
2
Backflow (if pumped)
PASS
PASS
+.
FAIL
Midtank Baffle
PASS
•
PASS
N/A
Water Tightness
PASS
PASS
FAIL
PUMPSIDOSING SIPHONS
Is a pump or dosing siphon present? Yes If Y: Is the pump/dosing siphon function properly? ye, -
Does the pump/wiring/dosing siphon appear to be in good condition? Yes
Is the high water alarm working; both visibly and audibly? `e5
Pumps/Dosing Siphon Pass/Fail: Pd.56
SECONDARY TREATMENT
Is a secondary treatment unit present? No D If Y: Does the unit appear to be in good working condition? No
Does the owner have a current maintenance contract for the unit? unkoN
Maintenance Provider I Phoner Email
Secondary Treatment Pass/Fail: N/A
If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin
County Environmental Health Department
ABSORSTION AREA
Effluent surfacing? NO Evidence of past surfacing? NO Surface dampness? NO
Excessive odors? NO
Field location verified by observation ports or probing: ES
Liquid in observation port? NO If Y: Recorded Depth (inches)
Distribution Box or ADV part of original Design? INo
If Y: Is it accessible from grade? NO If Y: Is it level and in good condition NO
Absorption Area Pass/Fail: PAS
Any problems with the system that were not addressed above?
The first tank was overfull when the inspection was conducted, but it was due to the fact that the filter was clogged. Once the
filter was cleaned everything went down to normal level.
List any recommendations for the continued use of the system:
:lump the first tank, and clean the filter annually or as needed.
Were any repairs done as a result of this inspection?
If Y: Describe repairs
Additional Notes:
Clearly label any pictures and upload them.❑✓
To the best of my knowledge and training the information collected in this inspection is accurate.
04/30/20
Inspectors Signature Date:
OS
W
23.4
7.8
4.4
0.8
7.3
3
2
.
4
25.9
3
2
.
4
3
3
.
2
26.7
1
5
.
8
11.4
3
2
.
2
34.2
1
5
.
3
N90°00'00"W 262.30'
Δ=25°17'55"
R=198.53'
DIST=87.66'
CH BRG=N19°38'45"W
CH DIST=86.95'
N
3
2
°
1
7
'
4
7
"
W
7
2
.
9
4
'
Δ=26°34'01"
R=57.13'
DIST=26.49'
CH BRG=N19°00'47"W
CH DIST=26.25'
N90°00'00"E 315.53'
S
0
7
°
5
7
'
2
3
"
E
1
7
0
.
0
0
'
20
.
0
'
20.0
'
20
.
0
'
30.0'
20.0'
7.
5
'
7.5'
7.
5
'
1 inch = ft.
(IN U.S. SURVEY FEET)
GRAPHIC SCALE
0020 10 20 40 80
20
BY
NO
.
DA
T
E
BY
PROJECT NO.
OR
5
3
4
-
0
6
7
0
0
I
N
M
E
T
R
O
D
E
N
V
E
R
UN
D
E
R
G
R
O
U
N
D
M
E
M
B
E
R
U
T
I
L
I
T
I
E
S
EX
C
A
V
A
T
E
F
O
R
T
H
E
M
A
R
K
I
N
G
O
F
BE
F
O
R
E
Y
O
U
D
I
G
,
G
R
A
D
E
,
O
R
CA
L
L
2
-
B
U
S
I
N
E
S
S
D
A
Y
S
I
N
A
D
V
A
N
C
E
1-
8
0
0
-
9
2
2
-
1
9
8
7
CE
N
T
E
R
O
F
C
O
L
O
R
A
D
O
CA
L
L
U
T
I
L
I
T
Y
N
O
T
I
F
I
C
A
T
I
O
N
RE
V
I
S
I
O
N
HI
G
H
C
O
U
N
T
R
Y
E
N
G
I
N
E
E
R
I
N
G
,
I
N
C
.
PH
O
N
E
(
9
7
0
)
9
4
5
-
8
6
7
6
-
F
A
X
(
9
7
0
)
9
4
5
-
2
5
5
5
ww
w
.
h
c
e
n
g
.
c
o
m
dr
a
w
n
b
y
:
ch
e
c
k
e
d
b
y
:
da
t
e
:
fi
l
e
:
15
1
7
B
L
A
K
E
A
V
E
N
U
E
,
S
T
E
1
0
1
,
GL
E
N
W
O
O
D
S
P
R
I
N
G
S
,
C
O
8
1
6
0
1
SHEET NUMBER
2191615
1 of 1
jo
h
n
h
u
g
h
e
s
sn
o
w
m
a
s
s
,
p
i
t
k
i
n
c
o
u
n
t
y
im
p
r
o
v
e
m
e
n
t
l
o
c
a
t
i
o
n
c
e
r
t
i
f
i
c
a
t
e
16
7
P
I
C
K
E
T
P
I
N
LA
N
E
WJ
N
BA
B
3.
2
1
.
1
9
IMPROVEMENT LOCATION CERTIFICATE
A TRACT OF LAND SITUATED IN LOT 9, BLOCK 1 OF THE
GATEWAY OF SNOWMASS MESA SUBDIVISION, FIRST FILING
SECTION 34, TOWNSHIP 8 SOUTH, RANGE 86 WEST OF THE 6TH P.M.
COUNTY OF PITKIN, STATE OF COLORADO
NOTES
1.DATE OF FIELD SURVEY: MARCH 18 2018, AT THE TIME OF THE SURVEY THERE WAS 2-3 FEET OF SNOW ON THE
GROUND.
2.THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY THIS SURVEYOR OF THE PROPERTY SHOWN AND
DESCRIBED HEREON TO DETERMINE:
A) OWNERSHIP OF THE TRACT OF LAND
B) COMPATIBILITY OF THIS DESCRIPTION WITH THOSE OF ADJOINERS
C) RIGHT'S-OF WAY, EASEMENTS AND ENCUMBRANCES OF RECORD AFFECTING THIS PARCEL.
3.FOR ALL INFORMATION REGARDING EASEMENT, RIGHTS-OF-WAY AND/OR TITLE OF RECORD, HIGH COUNTRY
ENGINEERING, INC. RELIED UPON TITLE COMMITMENT NO. Q62010225 ISSUED BY LAND TITLE GUARANTEE
COMPANY, EFFECTIVE DATE: MARCH 1, 2019
4.THE CLIENT DID NOT REQUEST THAT ANY ADDITIONAL EASEMENTS, RIGHT'S OF WAY AND/OR IMPROVEMENTS
BE RESEARCHED OR SHOWN ON THIS PLAT.
5.ANY PERSON WHO KNOWINGLY REMOVES, ALTERS OR DEFACES ANY PUBLIC LAND SURVEY MONUMENT OR
LAND BOUNDARY MONUMENT OR ACCESSORY COMMITS A CLASS TWO (2) MISDEMEANOR PURSUANT TO
SECTION 18-4-508 OF THE COLORADO REVISED STATUTES.
6.THE WORD "CERTIFY" AS SHOWN AND USED HEREON MEANS AN EXPRESSION OF PROFESSIONAL OPINION
REGARDING THE FACTS OF THE SURVEY, AS BASED UPON THE EVIDENCE PRESENTED HEREON, AND DOES NOT
CONSTITUTE A WARRANTY OR GUARANTEE, EXPRESSED OR IMPLIED.
7.NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED ON ANY DEFECT IN
THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT, MAY ANY ACTION
BASED ON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF
CERTIFICATION SHOWN HEREON.
8.NOTICE: THIS PLAT AND THE INFORMATION SHOWN HEREON MAY NOT BE USED FOR ANY ADDITIONAL OR
EXTENDED PURPOSE BEYOND THAT FOR WHICH IT WAS INTENDED AND MAY NOT BE USED BY ANY PARTIES
OTHER THAN THOSE TO WHICH IT IS CERTIFIED. THIS DOCUMENT AND THE WORK IT REPRESENTS IS THE
PROPERTY OF HIGH COUNTRY ENGINEERING, INC. NO PART OF THIS DOCUMENT MAY BE STORED,
REPRODUCED, DISTRIBUTED OR USED TO PREPARE DERIVATIVE PRODUCTS WITHOUT PRIOR WRITTEN
PERMISSION. AN ORIGINAL SEAL AND ORIGINAL SIGNATURE IS REQUIRED TO VALIDATE THIS DOCUMENT AND IS
EXCLUSIVE TO HIGH COUNTRY ENGINEERING, INC. AND THE OWNER(S) OF RECORD AS OF THIS DATE, OF THE
PROPERTY DELINEATED HEREON AND THE SUBJECT OF THE SURVEY. THIS PLAT IS RESTRICTED TO THE INTENT
OF TITLE 38, ARTICLE 50, §101, 5 (a) AND (b) C.R.S.
IMPROVEMENT LOCATION CERTIFICATE
I HEREBY STATE THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED BY HIGH COUNTRY
ENGINEERING, INC. FOR JOHN HUGHES, THAT IT IS NOT A LAND SURVEY PLAT OR AN IMPROVEMENT SURVEY PLAT,
AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE
IMPROVEMENT LINES.
I FURTHER STATE THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE OF MARCH 21, 2019
EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT
THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING
PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT
CROSSING OR BURDENING ANY PART OF SAID PARCEL, EXCEPT AS NOTED.
BILL W.A. BAKER, COLORADO PLS #23875
LEGEND
E
LOT 9
PARCEL ID:
246734301009
N/F
RANDOLPH AND JULIE RIEGER
167 PICKET PIN LANE
LOT 10
PARCEL ID:
246734301010
LOT 8
PARCEL ID:
246734301008
PARCEL ID:
246734400001
PARCEL ID:
246734300017
GRAVEL AREA
GARAGE
TWO-STORY
WOOD FRAME
HOUSE
STONE RETAINING WALL
(TYP.)
WOOD RETAINING WALL
(TYP.)
CONCRETE
RETAINING
WALL
(TYP.)
2ND FLOOR DECK
HOT TUB
1ST FLOOR PATIO
WITH WOOD
RETAINING WALL
BUILDING
OVERHANG (TYP.)
2ND FLOOR
BUILDING LINE
CONCRETE
(TYP.)
TIMBER FRAME
SWING
OVERHEAD ELECTRIC LINE
EASEMENT LINE
PROPERTY BOUNDARY LINE
ADJOINER LINE
WOOD FENCE LINE
FOUND PROPERTY CORNER - AS DESCRIBED
ELECTRICAL METERE
WATER SHUTOFF
OS
W
MAIL BOX
TELEPHONE PEDESTAL
UTILITY POLE/POWER POLE
AIR CONDITIONER
PAD
WOOD
STEPS
G
A
T
E
W
A
Y
R
O
A
D
P
I
C
K
E
T
P
I
N
L
A
N
E
ENCROACHING LANDSCAPE AREA SUBJECT TO
"LANDSCAPING ENCROACHMENT AGREEMENT"
RECEPTION #524087
20' ROAD AND UTILITY
EASEMENT
PER PLAT BK. 3, PG. 399
BUILDING SETBACK LINES
PER BK. 240, PG. 513
7.5' UTILITY EASEMENT
PER BK. 240, PG. 513
BUILDING SETBACK LINE
FOUND #5 REBAR WITH
RED PLASTIC CAP, ILLEGIBLE
HELD AS 20.19' WITNESS CORNER
ACCORDING TO ILC DONE BY
LINES IN SPACE DATED 10-14-2004
FOUND #5 REBAR WITH NO CAP
HELD AS 20.19' WITNESS CORNER
ACCORDING TO ILC DONE BY
LINES IN SPACE DATED 10-14-2004
0 0
RIEGER RESIDENCE
167 PICKET PIN LANE
PITKIN COUNTY, COLORADO
AS -BUILT DRAWINGS
1987 AND 2006
COVER SHEET
01 SITE PLAN
Al BASEMENT FLOOR PLAN
A2 MAIN FLOOR PLAN
A4.1 FRONT & RIGHT ELEVATIONS
A4.2 BACK & LEFT ELEVATIONS
RECEIVED
SEP 0 1 2006
PITKIN CUUN i Yt9VHUNMtNTAL
HEALTH & NATURAL RESOURCES
x
rW
iViW
0
0
RIEGER RESIDENCE
167 PICKET PIN LANELOT8OLDSNOWMASSCOLORADO
EAST 315.59'
101 UT411YEASEMENT
0
p
4 LOT 9
BLOCK 1
4.40 ACT.
GARAGE I GRAVELPAIWNG
2STORY \ MAMEnHOUSE
1f
UPLRYESEMENT \
WEST 26230
1
LOT10 LEGAL DESCRIPTION; LOT 9, BLOCK 1, GATEWAY OF SNOWMASS MESA SUBDMSION,
FILLING No. 1, PITKIN COUNTY, COLORADO.
L
wLd
Li] 3
U Z Q
a 3
Y ZQV (naoJ
0 O
STRUCTURAL ENGINEERS
VA4IEHORSECON9ILTANIS
m
FR YAAIW
DRAFTSMAN
LONG11dNOL9GN
parumoaiiwcenaruonIYIAMA
Plo¢ MII®1
Awa:
FO
mr om
0 0 0
ULLIFA
rLL.
W
W 5 r Z_ Q
1(
iY
a
C) a
c^o O
srRucruRalaclrvEexs
WHIIEIpK+E WN9ULTANF
w!rwueomcmnwnvcnouiwwm,r
DRAFTSMAN
oNaluaorscn
pO!01wm.Wnm
GO[ MM IF'/®R6M1E
oac
p9ic wxmi
s
auu¢- aom
WN - a000
ivno—aoa
q[4.
ay-
c-'i...'?. i'rl- -f -. ti' `vw... %T ^J6•. p'r'.•.kj:..`1->:::>'>.<,,,Xar >L •_< Y, •y:,t." ,c:i-(r1'._r.e...Y'ar.. •')'•v `. ...,J<Yr.•• Y ti .':.,3 YG7 :rr:`:_. `__ - ty r.....:r v_- i=,-t.:;>.2Y•,rr. l:cr. Li... k....i -.;a".' ai'f ' ]a•V_... t-J.p•..a -.R. i>S_...-ttJs4 ,_.+, t:4µS+:z'?-.-='u-ri:a 4.:',•. s. ti_,•- i'% LwiX_ilN'S`iY` arwa.v`.2._ ;s. Pia.:
4' tx fi_i;4•.?e:`c `y''!' a.t'."!- a;1 a. +i` I'' +,1 `• ra >y:.{.,•y:;x''a`. a> •ayt,'s.'t.
71CFOCKCAP
to exernsr
iFi'S J=;`_n ..a`J:`.it,.i.7L r,•t^ .s: 1'.y +.; a2',t,.i?iK•rp aS>•.: •:,'>:::z'{_..i 3ji}r3.Y' _rz s:'x..
1
5
1
t•a, rte ::•`:
FRONT ELEVATION AS -BUILT
SCALE: 1/411 = 1'-0"
O MATERIAL KEY:
7 LOG WALL
2 STUCCO
3 4gTMOPROOF
4 SOFFITX.'a`RtiTiti*S. 'i..,%i5 5 5 1%sSOFFTFANDFASCU
s Ixeriexosre
7 IxacoaNmeaornlw
2 0 SYNMETC FOCKYENEIIi
9 S7i1}
2
L
E3
RIGHT ELEVATION A9 -BUILT
SCALE: 1 /4" - V-0"
ULLIFA
rLL.
W
W 5 r Z_ Q
1(
iY
a
C) a
c^o O
srRucruRalaclrvEexs
WHIIEIpK+E WN9ULTANF
w!rwueomcmnwnvcnouiwwm,r
DRAFTSMAN
oNaluaorscn
pO!01wm.Wnm
GO[ MM IF'/®R6M1E
oac
p9ic wxmi
s
auu¢- aom
WN - a000
ivno—aoa
q[4.
ay-
71CFOCKCAP
to exernsr
ULLIFA
rLL.
W
W 5 r Z_ Q
1(
iY
a
C) a
c^o O
srRucruRalaclrvEexs
WHIIEIpK+E WN9ULTANF
w!rwueomcmnwnvcnouiwwm,r
DRAFTSMANoNaluaorscn
pO!01wm.Wnm
GO[ MM IF'/®R6M1E
oac
p9ic wxmi
s
auu¢- aomWN - a000ivno—aoa
q[4.
ay-
1
c) 1,0
SOFFTf
grew
3
Irwmmm
Mi
wua- mm
L
wvcas
2
BACK ELEVATION AS -BUILT
SCALE: 1 /4" = 1'-0"
0 MATERIAL KEY:
I LOG WALL
3 2 STUCM
5 3 HUrMOPRDOF
4rsr5 1 X 8 SOFFIT AND FASCIA
6 VXSHE4DF3q
7 JX4CORNERqWTRM
81 SOITICTICROCKVDIEER4
2 91 SYNTHEnCROCKCAP
1101 8%BPOSE
LEFT ELEVATION AS -BUILT
SCALE: 1/4"= 11-0"
c) 1,0
SOFFTf
grew
c) 1,0
grew
wrxmaalIrwmmm
Mi
wua- mm
wvcas
THE LOCATION OF EXISTING AND PROPOSED
IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A
PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE.
IT IS THE HOMEOWNERS DUTY TO ENSURE ALL
CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE
ACCURATE. ALL SETBACK DISTANCES SHOULD BE
CONFIRMED PRIOR TO EXCAVATION.
Legal Description;
LOT 9
BLOCK 1
4.40 ACT.
STEEP SLOPE
RECEIVED
SEP 0 1 2006
PITKINCOUNTY ENvIRUNMENTAL
HEALTH& NATURALRESOURCES
690 SF OF DRAIN FIELD IN ONE GRAVELLESS BED
USING SAND FILTER MATERIAL AND 'QUICK -4'
CHAMBERS.
5 ROWS OF 15'QUICK-4 CHAMBERS FOR A TOTAL OF
75 CHAMBERS,
8" OF CONCRETE SAND MUST BE PLACED BENEATH
CHAMBERS. A PERFORATED PVC PIPE MUST BE
SUSPENDED FULL LENGTH WITHIN CHAMBERS
UTILITY EASEMENT
EXISTING DRAIN FIELD MUST BE
ABANDONED
CONTOUR INTERVAL
AT APPROX 2 FEET.
NOT THE RESULT OF
A SURVEY
UTILITY EASEMENT
Lot 9, Block 1, Gateway of Snowmass mesa Subdivision,
Filling No.1, Pitkin County, Colorado.
GARAGE GRAVEL
PARKING
WEST 262.30'
OBSERVATIO
4 -BEDROOM
RESIDENCE
IPE
i0l0
SCALE
1
91= 20°
NORTH
STING 1250 -GALLON,
OMPARTMENT,PRECAST
NCRETE SEPTIC TANK
TH THE ADDITION OF A
IMP \
I
RE -DIRECT SEWER LINE TO
NEW TANK, AND PLACE
CLEANOUT. MUST BE
SCHEDULE 40 UNDER DRIVE.
ADD 1000 -GALLON, SINGLE
COMPARTMENT PRECAST
CONCRETE SEPTIC TANK WITH
EFFLUENT FILTER ON OUTLET.
RIEGER RESIDENCE
167 PICKET PIN LANE
OLD SNOWMASS COLORADO
Effluent Pumping Tank - Existing 1250 -Gallon Tank
CONCRETE —
RISER WITH LID
Tank Adapter —
cost or bolted)
Inlet Tee
ALARM IS
OPTIONAL
TANK SPECIFICATIONS
Slope Ground
Away from Riser
Conduit to
Control Panel
Conduit Seal—
PVC Splice Box
with Cord Grips
Fiberglass Gasketed Lid with
Stainless Steel Bolts
PVC Riser with Grommet(s)
bond to tank adapter with
recommended adhesive)
Discharge Assembly
Flexible Hose
Effluent Discharge
Tank Adapter (cast or bolted)
Level Control
Float Assembly
Check Valve (optional)
Pump
Drain Port
Pump Vault - Placed on Concrete Block
CAPACITY REQUIRED = q X 1.75 X (30 HOURS/24 HOURS) = 1750 GALLONS
REQUIRED TANK(S) = 1000 -GALLON, SINGLE -COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET, FOLLOWED
BY THE EXISTING 1250 -GALLON, TWO-COMPARTMENT TANK WITH THE ADDITION OF A PUMPIN THE SECOND COMPARTMENT.
TYPICAL PLAN VIEW - N.T.S.
4" PERFORATE
BE SUSPENDE
CHAMBERS
2" PUMP LINE
nQ CGD1/nTln l/\/GNT PIPGC (TW) 1 QUICK4(TM)
APS
LEVEL MANIFOLDX
INFILTRATOR(R) QUICK4(TM) CUT SHEET
52"
48"
EFFECTIVE LENGTH)
DESIGN
60'
CROSS SECTION OF TYPICAL CHAMBER -TRENCHES
EXTENT OF 4" SDR 35 PVC
EXCAVATION OBSERVATION/VENT
PIPE WITH CAP BACKFILL
SLOPE FOR
DRAINA0E 3
3' MAX
2' MIN
8'
4" PERFORATED PIPE MUST SCARIFY SURFACE INFILTRATOR(R) QUICKBESUSPENDEDWITHIN8CONCRETESANDCHAMBER, 3' X 4' CHAMBERS
BED MUST BE LEVEL
4 -BEDROOM MAIN RESIDENCE, <6000 SF = 800 GALLONS PER DAY
TOTAL LOADING = q = 1400 GALLONS PER DAY
PERCOLATION RATE = 12 MINUTES PER INCH
CALCULATED AREA = ((1.75 X q) X sgrt 12) / 5 = 970 SF
REDUCTION OF 30% = 670 SF
BED SPECIFICATIONS
WIDTH OF BED = 15 FEET = 5 CHAMBER
LENGTH OF BED = 60 FEET = 15 CHAMBERS
TOTAL NUMBER OF'QUICK-4' CHAMBERS = 75
PROPOSED NEW INFILTRATIVE AREA = 690 SF
NOTES:
BED MAY BE ANGLED TO FIT TOPOGRAPHY AND TO MINIMIZE
REMOVAL OF EXISTING VEGETATION. INFILTRATOR(R)
QUICK4(TM) CHAMBERS ARE CONSTRUCTED WITH A PIVOT
POINTS FOR THIS PURPOSE.
THE SLOPE AT THE PROPOSED DRAIN FIELD IS RELATIVELY FLAT.
VEGETATION CONSISTS OF A FULL COVER OF NATIVE GRASSES.
LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH
LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON
INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE
DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE
SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE
ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE
DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS
OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL
SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION
LL SERVICE septic, LLC 0167 PICKET PIN SANE PROJECT N0. 224
BOX 2844 SNOWMASS, COLORADO UPGRADE ONSITE WASTEWATER SYSTEM DESIGN 08-25-06oNwoo03sPRINGs,coslbo2 RIEGER RESIDENCE