Loading...
HomeMy WebLinkAboutPitkin.EH.246734301009 (2019)Page | 1 Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 www.aspenpitkin.com/EHNR Parcel ID #: 2467-343-01-009 OWTS Use Permit #: 0021.2019.POWU Date Issued: 5/6/2019 Issued By: Bryan Daugherty Expiration Date: 5/6/2020 Owner(s): Randy Rieger Property Address: 167 Picket Pin Lane Legal Description: Licensed Inspector: Travor Dunsdon Inspection Date(s): SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete two compartment tank Concrete two compartment tank 1250 Gallons 1250 Gallons Secondary Treatment Unit Absorption Area Gravelless Chamber trenches 680 ft2 Other System Components OWTS Use Status: In use at the time of the inspection. Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 06070 Date of Issuance: 9/13/06 Date of Final Approval: 11/10/06 # of Bedrooms or fixtures served by OWTS: This system was designed to serve 4 bedrooms. Operational Status: According to the inspector’s observations on site, the system appeared to be functioning as designed. Both tanks with in good working condition with tees and baffles in place. The effluent filter was clogged but was cleaned as part of the inspection. The field area did not show signs of failure such as surfacing effluent. Inspector Recommendations: Pump first tank in series in the near future. Clean effluent filter yearly or as needed. Department Recommendations: Continue maintenance as needed. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. 5/6/2019 Pitkin County Mail - Online Form Submittal: Property Sale/Remodel Use Permit Application https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632798502054008443&simpl=msg-f%3A16327985020…1/3 Bryan Daugherty <bryan.daugherty@pitkincounty.com> Online Form Submittal: Property Sale/Remodel Use Permit Application noreply@civicplus.com <noreply@civicplus.com>Mon, May 6, 2019 at 9:53 AM To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com Property Sale/Remodel Use Permit Application Please Note: Each OWTS System must be submitted individually. If there are additional systems on the property, additional applications are required. Job Parcel ID 2467343010009 Physical Address 167 Picket Pin, Snowmass, CO 81654 Residences 1 No. of Bedrooms 4 Square Footage of each Residence 3,265 Purpose of Use Permit Property Transaction Closing Date 5/17/2019 Lot 1 Block 9 Filing 1 Subdivision Gateway of Snowmass Subdivision (Section Break) Primary Contact Information Primary Contact First Name Thomas Primary Contact Last Name Carr Primary Contact Email Address tcarr@aspenreinfo.com Primary Contact Address 555 E Durant, Suite 5a Primary Contact Phone Number 970 925-5400 Primary Contact City Aspen Primary Contact State CO 5/6/2019 Pitkin County Mail - Online Form Submittal: Property Sale/Remodel Use Permit Application https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632798502054008443&simpl=msg-f%3A16327985020…2/3 Primary Contact Zip 81611 (Section Break) Owner Information Primary Contact is Owner?No Owner First Name Randy Owner Last Name Rieger Owner Email Address randyr@htgf.com Owner Mailing Address 3255 Aviation Ave, Ste 602 Owner City Coconut Grove Owner State FL Owner Zip 33133 Owner Phone 305 799-8144 Owner Fax Field not completed. Indicate Preferred Method of Payment Debit/Credit Card Payment Contact Email for Debit/Credit Payment tcarr@aspenreinfo.com (Section Break) Licensed Inspector Information Primary Contact is Licensed Inspector? No Inspector First Name Travor Inspector Last Name Dunsdon Inspector Email Address altitudeseptic@gmail.com Inspector Mailing Address PO Box 1534 Inspector City Eagle Inspector State CO Inspector Zip 81631 Inspector Phone Number 970 471-6292 Inspector Fax Number Field not completed. (Section Break) Uploads Pitkin County Inspection 167 Picket Pin Lane - Permit Inspection.pdf 5/6/2019 Pitkin County Mail - Online Form Submittal: Property Sale/Remodel Use Permit Application https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1632798502054008443&simpl=msg-f%3A16327985020…3/3 Form Site Plan NewILC-ReigerPropertyMarch2019.pdf Floor Plans RiegerEnvironmentalHealthPlans.pdf Additional Reports, etc.Field not completed. Comments or additional information: Field not completed. PLEASE READ BEFORE SELECTING SUBMIT: By selecting SUBMIT, I certify that I am the owner or representative with the legal authority to agree to the conditions of this permit, the above information is complete and accurate, and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. Building Permit Instructions If this application is part of a building permit application, please bring a copy of this application to your building Pre-Submittal meeting. To get a copy, either enter your email address to receive a copy of your application, or select "Submit and Print" below. Email not displaying correctly? View it in your browser. ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) D� USE PERMIT INSPECTION FORM 76 Service Center Rd Aspen CO 81611 ' 970-920-5070 Fax 970-920-5077 www.PitkinCounty.com Inspection for Permit Number: POWU Job Address (provide proof of application for an address if there is currently no address) _Address Application ob street: 167 Picket Pin Lane Job city: Snowmass Job state: CO Job zip 81654 Owner Owner First Name: Randy Owner Last Name: Rieger Owner Corporation Name: N/A Owner Mailing Address: 12,627 S. Bayshore Drive Apt 2 owner city: Miami lowner State: FL Owner Zip: 33133 Owner Phone: ( 005) 799-8144 Owner Cell Phone: Owner Ema":Irandyr@htgf.com Permit Contact Contact First Name: Om Contact Last Name: Carr ontact Business Name: Leverlch & Carr Contact Mailing Address: 555 E. Durant, suite 5a Contact City: [Aspen Contact State: CO Contact Zip: 81611 Contact Phone: (970) 925-5400 Contact Cell Phone: (970) 379-9935 Contact Email: cart@aspenreinfo.eom Licensed Inspector Inspector First Name: ravor Inspector Last Name: Dunsdon Inspector Business Name: ltitude Septic Inspector Mailing Address: PO BOX 1 534 Inspector City: Eagle Inspector State: CO Inspector Zip: 81631 Inspector Phone: (970) 471-6292 1 Inspector Cell Phone: (970) 471-6292 1 Inspector Email: altitudeseptic@gmail.com Inspector's License Number: 53 Parcel ID Z'� 6-7 -3Y.3 Legal Description Lot 9, Block 1, Filing 1, Gateway of Snowmass Mesa Subdivision A copy of this inspection will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. Questions For Property Owner PRIOR To Inspection: Is the home currently occupied? No How many bedrooms are in the home? If N: How long has it been vacant? 15-18 months RECORD Were system records available from Pitkin County? es If Y: Permit Number 06070 Date of final approval: 11/10/06 Was an as -built drawing available? es Is the as -built drawing accurate? es If N: Complete and upload a drawing of the system as accurately and possible ❑ Describe change in use differences: — No. of bedrooms permitted: SITE CONDITIONS Any questions marked FAIL or NO will require correction before an OWTS Usc permit is issued. Proper grading, no evidence of erosion: P-ASS-1 Proper vegetation cover: Fes M7 NO evidence of compaction such as heavy machinery or livestock: No Proper discharges (no straight pipes): PASS NO evidence of high ground water: No Snow cover is NOT present: No • Site Conditions Pass/Fail: PASS TANK(S) TANK TANK 2 TANK 3 Tank Capacity (gallons) 1250 1250 Tank Material Concrete Concrete Number of compartments 2 2 Date of last pumping Possibly 5-6'years Lids/risers PASS Lj PASS E11FAIL Risers to grade YES • ES 1-711NO Riser height 3 feet on inlet and 2 feet on outlet 1.5 feet on inlet 1 foot on c Riser condition/water tightness Good condition Good condition Inlet Sanitary T/Baffle PASS El PASS 1_7AIFAIL Outlet Sanitary T/Baffle PASS • iFASS FAIL Effluent Filter (if part of design) PASS N/A INO N/A Condition of Tank Material PASS • PASS FAIL Tank was pumped for inspection NO NO If Y: List Pumping Company If N: Date of last pumping Possibly 5-6 years Scum level (1st compartment) inches 0 Sludge level (1st compartment) inches 8 Scum level 2nd compartment) inches _ 0 Sludge level 2nd compartment) inches 2 Backflow (if pumped) PASS PASS +. FAIL Midtank Baffle PASS • PASS N/A Water Tightness PASS PASS FAIL PUMPSIDOSING SIPHONS Is a pump or dosing siphon present? Yes If Y: Is the pump/dosing siphon function properly? ye, - Does the pump/wiring/dosing siphon appear to be in good condition? Yes Is the high water alarm working; both visibly and audibly? `e5 Pumps/Dosing Siphon Pass/Fail: Pd.56 SECONDARY TREATMENT Is a secondary treatment unit present? No D If Y: Does the unit appear to be in good working condition? No Does the owner have a current maintenance contract for the unit? unkoN Maintenance Provider I Phoner Email Secondary Treatment Pass/Fail: N/A If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department ABSORSTION AREA Effluent surfacing? NO Evidence of past surfacing? NO Surface dampness? NO Excessive odors? NO Field location verified by observation ports or probing: ES Liquid in observation port? NO If Y: Recorded Depth (inches) Distribution Box or ADV part of original Design? INo If Y: Is it accessible from grade? NO If Y: Is it level and in good condition NO Absorption Area Pass/Fail: PAS Any problems with the system that were not addressed above? The first tank was overfull when the inspection was conducted, but it was due to the fact that the filter was clogged. Once the filter was cleaned everything went down to normal level. List any recommendations for the continued use of the system: :lump the first tank, and clean the filter annually or as needed. Were any repairs done as a result of this inspection? If Y: Describe repairs Additional Notes: Clearly label any pictures and upload them.❑✓ To the best of my knowledge and training the information collected in this inspection is accurate. 04/30/20 Inspectors Signature Date: OS W 23.4 7.8 4.4 0.8 7.3 3 2 . 4 25.9 3 2 . 4 3 3 . 2 26.7 1 5 . 8 11.4 3 2 . 2 34.2 1 5 . 3 N90°00'00"W 262.30' Δ=25°17'55" R=198.53' DIST=87.66' CH BRG=N19°38'45"W CH DIST=86.95' N 3 2 ° 1 7 ' 4 7 " W 7 2 . 9 4 ' Δ=26°34'01" R=57.13' DIST=26.49' CH BRG=N19°00'47"W CH DIST=26.25' N90°00'00"E 315.53' S 0 7 ° 5 7 ' 2 3 " E 1 7 0 . 0 0 ' 20 . 0 ' 20.0 ' 20 . 0 ' 30.0' 20.0' 7. 5 ' 7.5' 7. 5 ' 1 inch = ft. (IN U.S. SURVEY FEET) GRAPHIC SCALE 0020 10 20 40 80 20 BY NO . DA T E BY PROJECT NO. OR 5 3 4 - 0 6 7 0 0 I N M E T R O D E N V E R UN D E R G R O U N D M E M B E R U T I L I T I E S EX C A V A T E F O R T H E M A R K I N G O F BE F O R E Y O U D I G , G R A D E , O R CA L L 2 - B U S I N E S S D A Y S I N A D V A N C E 1- 8 0 0 - 9 2 2 - 1 9 8 7 CE N T E R O F C O L O R A D O CA L L U T I L I T Y N O T I F I C A T I O N RE V I S I O N HI G H C O U N T R Y E N G I N E E R I N G , I N C . PH O N E ( 9 7 0 ) 9 4 5 - 8 6 7 6 - F A X ( 9 7 0 ) 9 4 5 - 2 5 5 5 ww w . h c e n g . c o m dr a w n b y : ch e c k e d b y : da t e : fi l e : 15 1 7 B L A K E A V E N U E , S T E 1 0 1 , GL E N W O O D S P R I N G S , C O 8 1 6 0 1 SHEET NUMBER 2191615 1 of 1 jo h n h u g h e s sn o w m a s s , p i t k i n c o u n t y im p r o v e m e n t l o c a t i o n c e r t i f i c a t e 16 7 P I C K E T P I N LA N E WJ N BA B 3. 2 1 . 1 9 IMPROVEMENT LOCATION CERTIFICATE A TRACT OF LAND SITUATED IN LOT 9, BLOCK 1 OF THE GATEWAY OF SNOWMASS MESA SUBDIVISION, FIRST FILING SECTION 34, TOWNSHIP 8 SOUTH, RANGE 86 WEST OF THE 6TH P.M. COUNTY OF PITKIN, STATE OF COLORADO NOTES 1.DATE OF FIELD SURVEY: MARCH 18 2018, AT THE TIME OF THE SURVEY THERE WAS 2-3 FEET OF SNOW ON THE GROUND. 2.THIS SURVEY DOES NOT CONSTITUTE A TITLE SEARCH BY THIS SURVEYOR OF THE PROPERTY SHOWN AND DESCRIBED HEREON TO DETERMINE: A) OWNERSHIP OF THE TRACT OF LAND B) COMPATIBILITY OF THIS DESCRIPTION WITH THOSE OF ADJOINERS C) RIGHT'S-OF WAY, EASEMENTS AND ENCUMBRANCES OF RECORD AFFECTING THIS PARCEL. 3.FOR ALL INFORMATION REGARDING EASEMENT, RIGHTS-OF-WAY AND/OR TITLE OF RECORD, HIGH COUNTRY ENGINEERING, INC. RELIED UPON TITLE COMMITMENT NO. Q62010225 ISSUED BY LAND TITLE GUARANTEE COMPANY, EFFECTIVE DATE: MARCH 1, 2019 4.THE CLIENT DID NOT REQUEST THAT ANY ADDITIONAL EASEMENTS, RIGHT'S OF WAY AND/OR IMPROVEMENTS BE RESEARCHED OR SHOWN ON THIS PLAT. 5.ANY PERSON WHO KNOWINGLY REMOVES, ALTERS OR DEFACES ANY PUBLIC LAND SURVEY MONUMENT OR LAND BOUNDARY MONUMENT OR ACCESSORY COMMITS A CLASS TWO (2) MISDEMEANOR PURSUANT TO SECTION 18-4-508 OF THE COLORADO REVISED STATUTES. 6.THE WORD "CERTIFY" AS SHOWN AND USED HEREON MEANS AN EXPRESSION OF PROFESSIONAL OPINION REGARDING THE FACTS OF THE SURVEY, AS BASED UPON THE EVIDENCE PRESENTED HEREON, AND DOES NOT CONSTITUTE A WARRANTY OR GUARANTEE, EXPRESSED OR IMPLIED. 7.NOTICE: ACCORDING TO COLORADO LAW YOU MUST COMMENCE ANY LEGAL ACTION BASED ON ANY DEFECT IN THIS SURVEY WITHIN THREE YEARS AFTER YOU FIRST DISCOVER SUCH DEFECT. IN NO EVENT, MAY ANY ACTION BASED ON ANY DEFECT IN THIS SURVEY BE COMMENCED MORE THAN TEN YEARS FROM THE DATE OF CERTIFICATION SHOWN HEREON. 8.NOTICE: THIS PLAT AND THE INFORMATION SHOWN HEREON MAY NOT BE USED FOR ANY ADDITIONAL OR EXTENDED PURPOSE BEYOND THAT FOR WHICH IT WAS INTENDED AND MAY NOT BE USED BY ANY PARTIES OTHER THAN THOSE TO WHICH IT IS CERTIFIED. THIS DOCUMENT AND THE WORK IT REPRESENTS IS THE PROPERTY OF HIGH COUNTRY ENGINEERING, INC. NO PART OF THIS DOCUMENT MAY BE STORED, REPRODUCED, DISTRIBUTED OR USED TO PREPARE DERIVATIVE PRODUCTS WITHOUT PRIOR WRITTEN PERMISSION. AN ORIGINAL SEAL AND ORIGINAL SIGNATURE IS REQUIRED TO VALIDATE THIS DOCUMENT AND IS EXCLUSIVE TO HIGH COUNTRY ENGINEERING, INC. AND THE OWNER(S) OF RECORD AS OF THIS DATE, OF THE PROPERTY DELINEATED HEREON AND THE SUBJECT OF THE SURVEY. THIS PLAT IS RESTRICTED TO THE INTENT OF TITLE 38, ARTICLE 50, §101, 5 (a) AND (b) C.R.S. IMPROVEMENT LOCATION CERTIFICATE I HEREBY STATE THAT THIS IMPROVEMENT LOCATION CERTIFICATE WAS PREPARED BY HIGH COUNTRY ENGINEERING, INC. FOR JOHN HUGHES, THAT IT IS NOT A LAND SURVEY PLAT OR AN IMPROVEMENT SURVEY PLAT, AND THAT IT IS NOT TO BE RELIED UPON FOR THE ESTABLISHMENT OF FENCE, BUILDING, OR OTHER FUTURE IMPROVEMENT LINES. I FURTHER STATE THAT THE IMPROVEMENTS ON THE ABOVE DESCRIBED PARCEL ON THIS DATE OF MARCH 21, 2019 EXCEPT UTILITY CONNECTIONS, ARE ENTIRELY WITHIN THE BOUNDARIES OF THE PARCEL, EXCEPT AS SHOWN, THAT THERE ARE NO ENCROACHMENTS UPON THE DESCRIBED PREMISES BY IMPROVEMENTS ON ANY ADJOINING PREMISES, EXCEPT AS INDICATED, AND THAT THERE IS NO APPARENT EVIDENCE OR SIGN OF ANY EASEMENT CROSSING OR BURDENING ANY PART OF SAID PARCEL, EXCEPT AS NOTED. BILL W.A. BAKER, COLORADO PLS #23875 LEGEND E LOT 9 PARCEL ID: 246734301009 N/F RANDOLPH AND JULIE RIEGER 167 PICKET PIN LANE LOT 10 PARCEL ID: 246734301010 LOT 8 PARCEL ID: 246734301008 PARCEL ID: 246734400001 PARCEL ID: 246734300017 GRAVEL AREA GARAGE TWO-STORY WOOD FRAME HOUSE STONE RETAINING WALL (TYP.) WOOD RETAINING WALL (TYP.) CONCRETE RETAINING WALL (TYP.) 2ND FLOOR DECK HOT TUB 1ST FLOOR PATIO WITH WOOD RETAINING WALL BUILDING OVERHANG (TYP.) 2ND FLOOR BUILDING LINE CONCRETE (TYP.) TIMBER FRAME SWING OVERHEAD ELECTRIC LINE EASEMENT LINE PROPERTY BOUNDARY LINE ADJOINER LINE WOOD FENCE LINE FOUND PROPERTY CORNER - AS DESCRIBED ELECTRICAL METERE WATER SHUTOFF OS W MAIL BOX TELEPHONE PEDESTAL UTILITY POLE/POWER POLE AIR CONDITIONER PAD WOOD STEPS G A T E W A Y R O A D P I C K E T P I N L A N E ENCROACHING LANDSCAPE AREA SUBJECT TO "LANDSCAPING ENCROACHMENT AGREEMENT" RECEPTION #524087 20' ROAD AND UTILITY EASEMENT PER PLAT BK. 3, PG. 399 BUILDING SETBACK LINES PER BK. 240, PG. 513 7.5' UTILITY EASEMENT PER BK. 240, PG. 513 BUILDING SETBACK LINE FOUND #5 REBAR WITH RED PLASTIC CAP, ILLEGIBLE HELD AS 20.19' WITNESS CORNER ACCORDING TO ILC DONE BY LINES IN SPACE DATED 10-14-2004 FOUND #5 REBAR WITH NO CAP HELD AS 20.19' WITNESS CORNER ACCORDING TO ILC DONE BY LINES IN SPACE DATED 10-14-2004 0 0 RIEGER RESIDENCE 167 PICKET PIN LANE PITKIN COUNTY, COLORADO AS -BUILT DRAWINGS 1987 AND 2006 COVER SHEET 01 SITE PLAN Al BASEMENT FLOOR PLAN A2 MAIN FLOOR PLAN A4.1 FRONT & RIGHT ELEVATIONS A4.2 BACK & LEFT ELEVATIONS RECEIVED SEP 0 1 2006 PITKIN CUUN i Yt9VHUNMtNTAL HEALTH & NATURAL RESOURCES x rW iViW 0 0 RIEGER RESIDENCE 167 PICKET PIN LANELOT8OLDSNOWMASSCOLORADO EAST 315.59' 101 UT411YEASEMENT 0 p 4 LOT 9 BLOCK 1 4.40 ACT. GARAGE I GRAVELPAIWNG 2STORY \ MAMEnHOUSE 1f UPLRYESEMENT \ WEST 26230 1 LOT10 LEGAL DESCRIPTION; LOT 9, BLOCK 1, GATEWAY OF SNOWMASS MESA SUBDMSION, FILLING No. 1, PITKIN COUNTY, COLORADO. L wLd Li] 3 U Z Q a 3 Y ZQV (naoJ 0 O STRUCTURAL ENGINEERS VA4IEHORSECON9ILTANIS m FR YAAIW DRAFTSMAN LONG11dNOL9GN parumoaiiwcenaruonIYIAMA Plo¢ MII®1 Awa: FO mr om 0 0 0 ULLIFA rLL. W W 5 r Z_ Q 1( iY a C) a c^o O srRucruRalaclrvEexs WHIIEIpK+E WN9ULTANF w!rwueomcmnwnvcnouiwwm,r DRAFTSMAN oNaluaorscn pO!01wm.Wnm GO[ MM IF'/®R6M1E oac p9ic wxmi s auu¢- aom WN - a000 ivno—aoa q[4. ay- c-'i...'?. i'rl- -f -. ti' `vw... %T ^J6•. p'r'.•.kj:..`1->:::>'>.<,,,Xar >L •_< Y, •y:,t." ,c:i-(r1'._r.e...Y'ar.. •')'•v `. ...,J<Yr.•• Y ti .':.,3 YG7 :rr:`:_. `__ - ty r.....:r v_- i=,-t.:;>.2Y•,rr. l:cr. Li... k....i -.;a".' ai'f ' ]a•V_... t-J.p•..a -.R. i>S_...-ttJs4 ,_.+, t:4µS+:z'?-.-='u-ri:a 4.:',•. s. ti_,•- i'% LwiX_ilN'S`iY` arwa.v`.2._ ;s. Pia.: 4' tx fi_i;4•.?e:`c `y''!' a.t'."!- a;1 a. +i` I'' +,1 `• ra >y:.{.,•y:;x''a`. a> •ayt,'s.'t. 71CFOCKCAP to exernsr iFi'S J=;`_n ..a`J:`.it,.i.7L r,•t^ .s: 1'.y +.; a2',t,.i?iK•rp aS>•.: •:,'>:::z'{_..i 3ji}r3.Y' _rz s:'x.. 1 5 1 t•a, rte ::•`: FRONT ELEVATION AS -BUILT SCALE: 1/411 = 1'-0" O MATERIAL KEY: 7 LOG WALL 2 STUCCO 3 4gTMOPROOF 4 SOFFITX.'a`RtiTiti*S. 'i..,%i5 5 5 1%sSOFFTFANDFASCU s Ixeriexosre 7 IxacoaNmeaornlw 2 0 SYNMETC FOCKYENEIIi 9 S7i1} 2 L E3 RIGHT ELEVATION A9 -BUILT SCALE: 1 /4" - V-0" ULLIFA rLL. W W 5 r Z_ Q 1( iY a C) a c^o O srRucruRalaclrvEexs WHIIEIpK+E WN9ULTANF w!rwueomcmnwnvcnouiwwm,r DRAFTSMAN oNaluaorscn pO!01wm.Wnm GO[ MM IF'/®R6M1E oac p9ic wxmi s auu¢- aom WN - a000 ivno—aoa q[4. ay- 71CFOCKCAP to exernsr ULLIFA rLL. W W 5 r Z_ Q 1( iY a C) a c^o O srRucruRalaclrvEexs WHIIEIpK+E WN9ULTANF w!rwueomcmnwnvcnouiwwm,r DRAFTSMANoNaluaorscn pO!01wm.Wnm GO[ MM IF'/®R6M1E oac p9ic wxmi s auu¢- aomWN - a000ivno—aoa q[4. ay- 1 c) 1,0 SOFFTf grew 3 Irwmmm Mi wua- mm L wvcas 2 BACK ELEVATION AS -BUILT SCALE: 1 /4" = 1'-0" 0 MATERIAL KEY: I LOG WALL 3 2 STUCM 5 3 HUrMOPRDOF 4rsr5 1 X 8 SOFFIT AND FASCIA 6 VXSHE4DF3q 7 JX4CORNERqWTRM 81 SOITICTICROCKVDIEER4 2 91 SYNTHEnCROCKCAP 1101 8%BPOSE LEFT ELEVATION AS -BUILT SCALE: 1/4"= 11-0" c) 1,0 SOFFTf grew c) 1,0 grew wrxmaalIrwmmm Mi wua- mm wvcas THE LOCATION OF EXISTING AND PROPOSED IMPROVEMENTS SHOWN ARE NOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONS ARE APPROXIMATE. IT IS THE HOMEOWNERS DUTY TO ENSURE ALL CONSTRUCTION AND IMPROVEMENTS LOCATIONS ARE ACCURATE. ALL SETBACK DISTANCES SHOULD BE CONFIRMED PRIOR TO EXCAVATION. Legal Description; LOT 9 BLOCK 1 4.40 ACT. STEEP SLOPE RECEIVED SEP 0 1 2006 PITKINCOUNTY ENvIRUNMENTAL HEALTH& NATURALRESOURCES 690 SF OF DRAIN FIELD IN ONE GRAVELLESS BED USING SAND FILTER MATERIAL AND 'QUICK -4' CHAMBERS. 5 ROWS OF 15'QUICK-4 CHAMBERS FOR A TOTAL OF 75 CHAMBERS, 8" OF CONCRETE SAND MUST BE PLACED BENEATH CHAMBERS. A PERFORATED PVC PIPE MUST BE SUSPENDED FULL LENGTH WITHIN CHAMBERS UTILITY EASEMENT EXISTING DRAIN FIELD MUST BE ABANDONED CONTOUR INTERVAL AT APPROX 2 FEET. NOT THE RESULT OF A SURVEY UTILITY EASEMENT Lot 9, Block 1, Gateway of Snowmass mesa Subdivision, Filling No.1, Pitkin County, Colorado. GARAGE GRAVEL PARKING WEST 262.30' OBSERVATIO 4 -BEDROOM RESIDENCE IPE i0l0 SCALE 1 91= 20° NORTH STING 1250 -GALLON, OMPARTMENT,PRECAST NCRETE SEPTIC TANK TH THE ADDITION OF A IMP \ I RE -DIRECT SEWER LINE TO NEW TANK, AND PLACE CLEANOUT. MUST BE SCHEDULE 40 UNDER DRIVE. ADD 1000 -GALLON, SINGLE COMPARTMENT PRECAST CONCRETE SEPTIC TANK WITH EFFLUENT FILTER ON OUTLET. RIEGER RESIDENCE 167 PICKET PIN LANE OLD SNOWMASS COLORADO Effluent Pumping Tank - Existing 1250 -Gallon Tank CONCRETE — RISER WITH LID Tank Adapter — cost or bolted) Inlet Tee ALARM IS OPTIONAL TANK SPECIFICATIONS Slope Ground Away from Riser Conduit to Control Panel Conduit Seal— PVC Splice Box with Cord Grips Fiberglass Gasketed Lid with Stainless Steel Bolts PVC Riser with Grommet(s) bond to tank adapter with recommended adhesive) Discharge Assembly Flexible Hose Effluent Discharge Tank Adapter (cast or bolted) Level Control Float Assembly Check Valve (optional) Pump Drain Port Pump Vault - Placed on Concrete Block CAPACITY REQUIRED = q X 1.75 X (30 HOURS/24 HOURS) = 1750 GALLONS REQUIRED TANK(S) = 1000 -GALLON, SINGLE -COMPARTMENT, CONCRETE SEPTIC TANK WITH AN EFFLUENT FILTER ON THE OUTLET, FOLLOWED BY THE EXISTING 1250 -GALLON, TWO-COMPARTMENT TANK WITH THE ADDITION OF A PUMPIN THE SECOND COMPARTMENT. TYPICAL PLAN VIEW - N.T.S. 4" PERFORATE BE SUSPENDE CHAMBERS 2" PUMP LINE nQ CGD1/nTln l/\/GNT PIPGC (TW) 1 QUICK4(TM) APS LEVEL MANIFOLDX INFILTRATOR(R) QUICK4(TM) CUT SHEET 52" 48" EFFECTIVE LENGTH) DESIGN 60' CROSS SECTION OF TYPICAL CHAMBER -TRENCHES EXTENT OF 4" SDR 35 PVC EXCAVATION OBSERVATION/VENT PIPE WITH CAP BACKFILL SLOPE FOR DRAINA0E 3 3' MAX 2' MIN 8' 4" PERFORATED PIPE MUST SCARIFY SURFACE INFILTRATOR(R) QUICKBESUSPENDEDWITHIN8CONCRETESANDCHAMBER, 3' X 4' CHAMBERS BED MUST BE LEVEL 4 -BEDROOM MAIN RESIDENCE, <6000 SF = 800 GALLONS PER DAY TOTAL LOADING = q = 1400 GALLONS PER DAY PERCOLATION RATE = 12 MINUTES PER INCH CALCULATED AREA = ((1.75 X q) X sgrt 12) / 5 = 970 SF REDUCTION OF 30% = 670 SF BED SPECIFICATIONS WIDTH OF BED = 15 FEET = 5 CHAMBER LENGTH OF BED = 60 FEET = 15 CHAMBERS TOTAL NUMBER OF'QUICK-4' CHAMBERS = 75 PROPOSED NEW INFILTRATIVE AREA = 690 SF NOTES: BED MAY BE ANGLED TO FIT TOPOGRAPHY AND TO MINIMIZE REMOVAL OF EXISTING VEGETATION. INFILTRATOR(R) QUICK4(TM) CHAMBERS ARE CONSTRUCTED WITH A PIVOT POINTS FOR THIS PURPOSE. THE SLOPE AT THE PROPOSED DRAIN FIELD IS RELATIVELY FLAT. VEGETATION CONSISTS OF A FULL COVER OF NATIVE GRASSES. LIMITATIONS - THESE PLANS MUST BE USED IN CONJUNCTION WITH LETTER AND SOILS DATA FORM PROVIDED. THE DESIGN IS BASED UPON INFORMATION SUBMITTED. IF SOIL CONDITIONS ENCOUNTERED ARE DIFFERENT FROM CONDITIONS DESCRIBED IN REPORT, ALL SERVICE SEPTIC L.L.C. SHOULD BE NOTIFIED. ALL OWS CONSTRUCTION MUST BE ACCORDING TO COUNTY REGULATIONS. THE INSTALLER SHOULD HAVE DEMONSTRATED KNOWLEDGE OF THE REQUIREMENTS AND REGULATIONS OF THE COUNTY IN WHICH THEY ARE WORKING. THE COUNTY AND ALL SERVICE SEPTIC L.L.C.MUST VIEW INSTALLATION LL SERVICE septic, LLC 0167 PICKET PIN SANE PROJECT N0. 224 BOX 2844 SNOWMASS, COLORADO UPGRADE ONSITE WASTEWATER SYSTEM DESIGN 08-25-06oNwoo03sPRINGs,coslbo2 RIEGER RESIDENCE