HomeMy WebLinkAboutPitkin.EH.273510202007 (2019)Bryan Daugherty <bryan.daugherty@pitkincounty.com>
Online Form Submittal: Property Sale/Remodel Use Permit Application
1 message
noreply@civicplus.com <noreply@civicplus.com>Wed, Jul 31, 2019 at 11:24 AM
To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com
Property Sale/Remodel Use Permit Application
Please Note: Each OWTS System must be submitted individually. If there are
additional systems on the property, additional applications are required.
Job Parcel ID 2735102007
Physical Address 401 Eagle Park Dr, Aspen CO 81611
Residences 1
No. of Bedrooms 5
Square Footage of each
Residence
12674
Purpose of Use Permit Remodel/Addition
Lot Lot 7
Block Field not completed.
Filing Field not completed.
Subdivision Eagle Pines
(Section Break)
Primary Contact Information
Primary Contact First Name Noah
Primary Contact Last Name Czech
Primary Contact Email
Address
noahc@cunniffe.com
Primary Contact Address 610 E Hyman Ave
Primary Contact Phone
Number
9709255590
Primary Contact City Aspen
Primary Contact State CO
Primary Contact Zip 81611
(Section Break)
Owner Information
Primary Contact is Owner?No
Owner First Name Randy
Owner Last Name Metz
Owner Email Address rmetz@parkmetzlaw.com
Owner Mailing Address 329 Main Street
Owner City Carbondale
Owner State CO
Owner Zip 81623
Owner Phone 9703404977
Owner Fax 9709635905
Indicate Preferred Method of
Payment
Check
Payment Contact Email for
Debit/Credit Payment
rmetz@parkmetzlaw.com
(Section Break)
Licensed Inspector Information
Primary Contact is Licensed
Inspector?
No
Inspector First Name Tom
Inspector Last Name Scott
Inspector Email Address tjs@hceng.com
Inspector Mailing Address 1517 Blake Ave
Inspector City Glenwood Springs
Inspector State CO
Inspector Zip 81601
Inspector Phone Number 9709458676
Inspector Fax Number Field not completed.
(Section Break)
Uploads
Pitkin County Inspection
Form
15.Aspen Sanitation.pdf
Site Plan 38.Site Plan.pdf
Floor Plans 38.Building Plans.pdf
Additional Reports, etc.38.Site Plan.pdf
Comments or additional
information:
Thanks for working on this. Let me know if you have any
questions.
Noah (970)925-5590 noahc@cunniffe.com
PLEASE READ BEFORE SELECTING SUBMIT:
By selecting SUBMIT, I certify that I am the owner or representative with the legal
authority to agree to the conditions of this permit, the above information is complete
and accurate, and that I have provided complete and accurate information in all of
the documents included in my application package. I acknowledge that this
department may revoke any permit I am issued if my application is found to contain
any inaccurate, false, or misleading information.
Building Permit Instructions
If this application is part of a building permit application, please bring a copy of this
application to your building Pre-Submittal meeting. To get a copy, either enter your
email address to receive a copy of your application, or select "Submit and Print"
below.
Email not displaying correctly? View it in your browser.
D ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
A USE PERMIT INSPECTION FORM
76 Service Center Rd Aspen CO 81611
970-920-5070 Fax 97&920-5077
www.PltklnCoun .com
Inspection for Permit Number: 02036 POWU
job Address (provide proof ofappliration for an addrass'dthere is arrently no adtlress AtltlressA Ikation
ob streec401 Eagle Park Drive Job Cky:N/A
Job state:C0 mbzlp
TtI
Owner
owner First N.rr.:1 UDC Eagle Pines LLC
owner Last Name:
N/A
owner corporation Name:
N/A
owner Mailing Mdrms:250
IMironDrive
IOwnercity:Soulh
Lake
wnerstate:TX
0wnerzip:76092
Owner Phone:
Owner Cell Phone:_
Owner Email
N/A
Permit Contact
Contact First Name:
Karen
I Contact Last Name:
Toth
onnaa Business Name
Koren Toth Realty, Inc.
Contact Mailing Address:
ontact
City:
ContaRState: CD
Cantaa Zip:
I
Cornea Phone:
(970) 379-5252
1 Contact Cell Phone
(970) 379-5252
1
Contact Email:
Karen@KarenTodFcom
Licensed Inspector
Inspector First Name:Tom
Inspector last Name:
Seou
Inspenor Business Name:High
Country Engineering
Inspector Mailing Address:
1517
JBIake Ave. IIrspector Ctty:Glenwood
Springs IInspeaor5tate:CO
I
lnspeaorzip:81601
Inspector Phone
(970)945-8676
Inspector Cell Phone:
Inspector Email:tfg@hpeag.eom
Inspector's License Number:
20
Parcel ID 273510202007
Legal Description Lot 7 Eagle Pines Subdivision
A copYof this inspection will be remitted W Pitkin County Environmental Health Department bythe Licensed systems ImpectorwRhin fA days ofthe
inspection regardless of whether the system passes or fails.
Questions For Property Owner PRIOR To Inspection:
Is the home currently occupied? No
How many bedrooms are in the home? 15
If N: How long has it been vacant? N/A
RECORDS
Were system records available from Pitkin County? Yes
If Y: Permit Number 02036 Date offinal approval: 10/31/U4
Was an as -built drawing available? Yes
Is the as -built drawing accurate? Yes
HIM: Complete and upload a drawing of the system as accurately and possible ❑✓
Describe char a In use differences:
No. of bedrooms permitted:0
SITE CONDITIONS
Any questions marked FAIL or NO will require correction before an OWTS Use permit is issued.
Proper grading, no evidence of erosion: PASS 1 Proper vegetation cover: yes
NO evidence of compaction such as heavy machinery or livestock: rN.
Proper discharges (no straight pipes): PASS 1 NO evidence of high ground water: No
Snow cover is NOT present: No
Site Conditions Pau/Fail: PASS
TANK(S) TANK TANK TANK
Tank Capacity (gallons)
2,000
1,250
Tank Material
Concrete
Concrete
Number ofcompartments
One
Two
Date of last pumping
Unknowa
Unknown
Lids/risers
PASS
PASS
Risers to grade
YES
YES
Riser height
T - 0"
Y - 0"
Riser condition/watertightness
Unknoum
Unknown
Inlet Sanitary T/Baffle
PASS
PASS
Outlet Sanitary T/Baffle
PASS
PASS
Effluent Filter If pan of design)
PASS
IPASS
Condition of Tank Material
PASS
PASS
Tank was pumped for inspection
NO
NO
If y: List Pumping Company
N/A
N/A
If N: Date of last pumping
Unknown
Unknown
Scum level (1st compartment) inches
6"
6"
Sludge level (1st compartment) inches
12"
12"
Scum level 2nd compartment) inches
6"
6"
Judge level 2nd compartment) Inches
12"
12"
BackFlow(if pumped)
N/A
N/A
Midtank Baffle
PASS
N/A
Water Tightness
PASS 111PASS
PUMPS/DOSING SIPHONS
Is a pump or dosing siphon present? Yes Ify: Is the pump/dosing siphon function properly. Yes
Does the pump/wiring/dosing siphon appearto be in good condition? Yes
Is the high water alarm working; both visibly and audibly? NO
Pumps/Dosing Siphon Pass/Fail: FAIL
SECONDARY TREATMENT
Is a secondary treatment unit present? No If Y: Does the unit appear to be in good working condition? N/A
Does the owner have a current maintenance contract for the unit? Unkoum
Maintenance Provider jUnknown Phone N/A Email N/A
Secondary Treatment Pass/Fail: N/A
It there is no maintenance contract, a contract most be In place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin
County Environmental Health Department
ABSORSTION AREA
Effluent surfacing? NO Evidence of past surfacing? NO Surface dampness? NO
Excessive odors? NO
Field location verified by observation ports or probing: YES
Liquid in observation port? FNO IfY: Recorded Depth (inches) O
Distribution Box or ADV part of original Design? Yes
If Y: Is it accessible from grade? NO If Y: Is it level and in good condition N/A
Absorption Area Pass/Fail: PASS
Any problems withthesystern thatwere notaddressed above?
1. Unable to verify the successful operation of septic tank visual and audible high water alarm.
2. Presence ofpresumed roofdram discharge pipe and irrigation sprinklers at absorption area, noted during inspection.
3. Presence ofpossible spa drain discharge pipe connected to second septic tank, noted during inspection.
4. Unable to locate and inspoetburied distribution box during inspection.
List any recommendations for the continued use of thesystem:
1. Recommend evaluation and repair of septic tank visual and audible high water alarm.
. Recommend removal of presumed roof drain discharge pipe and irrigation sprinklers from absorption area, per County compliance.
. Recommend removal of possible spa dram discharge pipe connected to second septic rank, per County compliance.
. Recommend locating distribution box and installing access risers and removable cover to grade, needed for inspection.
Were any repairs done as a msuIt of this inspection?
If Y: Describe repairs
No
Additional Notes:
Clearly label any pictures and upload them.
171
To the heat of me k-1-cige and trainingthe information collected in this inspection is accurate.
09/25/16
Insp- Date:
Save Form for Submittal
Reset this form
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
7/
3
1
/
2
0
1
9
1
1
:
2
0
:
5
8
A
M
A1.2
1918
SITE PLAN -
SEPTIC
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
SITE PLAN - SEPTIC
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
6/
5
/
2
0
1
9
2
:
4
0
:
1
2
P
M
EAGLE PARK REMODEL
CVR
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
401 EAGLE PARK DRIVE
PITKIN COUNTY, CO
PERMIT SET 05/31/19
ARCHITECTURAL SYMBOLS
SYMBOL LEGEND
SPOT ELEVATION
NEW CONTOUR
EXISTING CONTOUR
CENTER LINE
HIDDEN LINE
SETBACK LINE
BREAK LINE
PROPERTY LINE
ROOM NAME
ROOM NUMBER
REVISIONS
KEYNOTE
SHEET NUMBER
CAST
BATTCOMPACTED FILL
POROUS FILL
UNDISTURBED SOILS
CONCRETE BLOCK
BRICK
STONE
GLASS BLOCK
STEEL
RIGID
FINISH
WD. FRAMING
WD. BLOCKING
GLU-LAM
PLYWOOD
PLAN & SECTION
MATERIAL INDICATIONS
VICINITY MAP
GENERAL NOTES
EARTH
ROCK
CONCRETE
MASONRY
METAL
INSULATION
WOOD
MATCH LINE
PROJECT NORTH
TRUE NORTH
GROUT, LIGHTWEIGHT
CONCRETE
ARCHITECTURAL ABBREVIATIONS
ZONING & BUILDING CODE INFORMATION
SHEET INDEX
PROJECT DIRECTORY
ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE
WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS, AND THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL CONFINE HIS/HER OPERATIONS ON THE SITE TO AREAS
PERMITTED BY THE OWNER.
SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE
SPECIFICATIONS SHALL TAKE PRECEDENCE. UNLESS A WRITTEN DECISION FROM THE
ARCHITECT HAS BEEN OBTAINED WHICH DESCRIBES A CLARIFICATION OR ALTERNATE
METHOD AND/OR MATERIALS.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING
WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE
CONTRACT DOCUMENTS AND EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR
INSTRUCTION ON HOW TO PROCEED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW
CONSTRUCTION ON THE SITE. THE CONTRACTOR SHALL PROVIDE COMPLETE BUILDING SYSTEMS
AND COMPONENTS IN COMPLIANCE WITH MANUFACTURERS' REQUIREMENTS AND
RECOMMENDATIONS. ALL SEQUENCING, INTERFACE AND COORDINATION WITH OTHER
BUILDING TRADES SHALL BE AS REQUIRED FOR COMPLETE, PROPERLY INSTALLED AND
OPERATING SYSTEMS AND/OR BUILDING COMPONENTS, AND SHALL MEET OR EXCEED
QUALITY LEVELS OF COMMONLY ACCEPTED CONSTRUCTION PRACTICE AND INDUSTRY
STANDARDS. CONTACT ARCHITECT WITH ANY QUESTIONS PRIOR TO STARTING WORK.
THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION, FREE OF DEBRIS
AND LITTER, AND SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR
EQUIPMENT. EACH SUB-CONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF
HIS/HER WORK SHALL REMOVE ALL TRASH AND DEBRIS AS OF RESULT OF HIS/HER
OPERATION.
ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED
TO PREVENT DAMAGE AND DETERIORATION. FAILURE TO PROTECT MATERIALS MAY BE
CAUSE FOR REJECTION OF WORK.
WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER PIPING AND CONDUITS,
THE LARGER STUD SIZE OR FURRING SHALL EXTEND THE FULL SURFACE OF THE WALL
WIDTH AND LENGTH WHERE THE FURRING OCCURS.
PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED
SPACES, VOIDS, ATTICS, ECT. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION.
THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF HIS/HER WORK THAT MAY
BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND SHALL NOT
ENDANGER ANY OTHER WORK BY CUTTING, EXCAVATING, OR OTHERWISE ALTERING THE TOTAL
WORK OR ANY OTHER PART OF IT. ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS
AND SURFACES CUT OR DAMAGED IN EXECUTION OF WORK SHALL BE DONE WITH APPLICABLE
MATERIALS SO THAT SURFACES REPLACED WILL, UPON COMPLETION, MATCH SURROUNDING
SIMILAR SURFACES.
CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING, AND FRAMING
FOR LIGHT FIXTURES, ELECTRICAL UNITS, A.C. EQUIPMENT, RECESSED ITEMS, AND ALL
OTHER ITEMS AS REQUIRED.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
2015 I.R.C. AND ANY REQUIREMENTS BY THE LOCAL BUILDING DEPARTMENT
ZONING AR-10
AFF
BM
BS.
B.O.
ACCOUS
ADJ
ALT
ALUM
APPD
APPROX
ARCH
ASAP
BRG
BET
BLK
BSMT
BTU
BLDG
CAB
CLG
CER
CLR
ABOVE FINISHED FLOOR
ADJACENT
ALTERNATE
ALUMINUM
APPROXIMATE
APPROVED
BEAM
BEARING
BETWEEN
BLOCK
BASEMENT
BRITISH THERMAL UNIT(S)
BOARDBD
BOTH SIDES
BOTTOM OF
BUILDING
CABINET
CENTER LINE
CEILING
CERAMIC
CLEAR
CJ
CF
DP
DW
DN
DR
EA.
EW
CLO CLOSET
D
W
COL
CONC
CONT
COORD
CTR
DEPT
DTL
DIA,
DIM
DWG
ELECT
CLOTHES DRYER
CLOTHES WASHER
COLUMN
CONCRETE
CONSTRUCTION JOINT
CONTINUOUS
COORDINATE
COUNTER
CUBIC FEET
DAMPROOFING
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DOWN
DRAIN
DRAWING
EACH
EACH WAY
ELECTRICAL
EL
EQ
F.O.
FP
FD
FT
GA
GC
GL
GRD.
HD
HP
HT
ID
JT
ENGR
EXG
EXP.
EXT.
FIN
FIXT
FTG
FDN
FURN
GAL
GALV
GYP.
GWB
HDW
HVAC
HORIZ
HWH
INCL
INFO
INSUL
ELEVATION
ENGINEER
EQUAL
EXISTING
EXPOSED
EXTERIOR
FACE OF
FINISH
FIREPROOF
FIREPLACEFPL
FIXTURE
FLOOR
FLOOR DRAIN
FOOT, FEET
FOOTING
FOUNDATION
FURNISH
GALLON
GAUGE
GALVINIZED
GENERAL CONTRACTOR
GLASS, GLAZED
GRADE
GYPSUM
GYPSUM WALLBOARD
HARDWARE
HEAD
HORIZONTAL
HORSE POWER
HOT WATER HEATER
HEIGHT
INCLUDE (D) (ING)
INFORMATION
INSIDE DIAMETER
INSULATION
JOINT
INT INTERIOR
HEATING, VENTING, AND
AIR CONDITIONING
LT
MO
NA
OD
d
QT
R
RD
RM
JCT
KWH
LAV
MFR
MATL
MTL
MAX
MECH
MED
JUNCTION
KILOWATT HOUR
LAVATORY
LIGHT
MANUFACTURER
MATERIAL
MASONRY OPENING
METAL
MAXIMUM
MECHANICAL
MEDIC (INE) (AL)
MIN
MISC
NOM
NIC
NTS
OPG
OC
OPP
ORN
PTN
PERF PERFORATE(D)
PENNY (NAILS, ECT.)
MINIMUM
MISCELLANEOUS
NOMINAL
NOT IN CONTRACT
NOT APPLICABLE
NOT TO SCALE
ON CENTER
OPENING
OPPOSITE
ORNAMENTAL
OUTSIDE DIAMETER
PARTITION
PLT.
PLY
QTY
PLATE
PLYWOOD
QUARRY TILE
QUANTITY
RADIUS
ROOF DRAIN
ROOM
RS ROUGH SAWN
RW
R
RO
SQ
SS
TV
TO
T
UG
RCB
REF.
REFR
REINF
REBAR
REQD
SHT
SHLV
SVF
SIM
STC
SPEC
SF
RESILIENT COVE BASE
RETAINING WALL
REFER/REFERENCE
REFRIGERATOR
REINFORCE ( D)
REINFORCING BAR (S)
REQUIRED
RISER
ROUGH OPENING
SHEET
SHEET VINYL FLOORING
SHELV (ES) (ING)
SIMILAR
SOUND-TRANSMISSION CLASS
SPECIFICATION
SQUARE
SQUARE FEET
STD
STRUCT
SUB
SUPPL
S4S
SUSP
TEL
TEMP
T&G
T&B
TYP TYPICAL
STANDARD
STRUCTURAL
SUBSTITUTE
SUPPLEMENT
SURFACED FOUR SIDES
SUSPEND(ED)
TELEPHONE
TELEVISION
TOP AND BOTTOM
TONGUE AND GROOVE
TOP OF
TREAD
V
WH
WC
WP
WT
W/
WD
UNGL
UNFIN
VIF
VERT
VCT
WWF
WDW
W/O
UNGLAZED
UNFINISHED
VERIFY IN FIELD
VERTICAL
VOLT
WATER HEATER
WATER CLOSET
WATERPROOF
WEIGHT
WELDED WIRE FABRIC
WINDOW
WITH
WITHOUT
WOOD
ACOUSTICAL
ARCHITECT (URAL)
BFF BELOW FINISHED FLOOR
CL,
DISHWASHER
LAM LAMINATE (D)
OPH OPPOSITE HAND
STL STEEL
TEMPERED
AS SOON AS POSSIBLE
FLR
STAINLESS STEEL
VINYL COMPOSITION TILE
U.N.O.UNLESS NOTED OTHERWISE
UNDERGROUND
ARCHITECT STRUCTURAL ENGINEER CONTRACTOR
ZONING INFORMATION:
APPLICABLE CODES:
DIMENSIONS:
A. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE OF DRAWINGS.
B. ALL DIMENSIONS ARE TO FACE OF STUD or FACE OF CONCRETE U.N.O.
C. ALL EXTERIOR STUDS TO BE 2x6 U.N.O.
ALL INTERIOR STUDS TO BE 2x4 U.N.O.
ALL INTERIOR STUD WALLS & CEILINGS BETWEEN LIVING SPACES SHALL HAVE
3 1/2 " SOUND ATTENUATION BATTS UNLESS THERMAL INSULATION IS CALLED FOR.
(WHEN
APPLICABLE)
INTERIOR ELEVATION
WINDOW NUMBER
CHARLES CUNNIFFE ARCH.
610 E. HYMAN AVE.
ASPEN, COLORADO 81611
TELE: (970) 925-5590
FAX: (970) 920-4557
BUILDING TYPE AND OCCUPANCY:
TYPE V / GROUP R3 OCCUPANCY
FULLY SPRINKLERED
PROVIDE FIRE SPRINKLER PROTECTION THROUGHOUT THE BUILDING. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR PREPARING THE DRAWINGS AND OBTAINING THE PERMITS
FOR THE FIRE SPRINKLER SYSTEM. THE FIRE SPRINKLER SYSTEMS SHALL MEET THE
REQUIREMENTS OF ALL APPLICABLE CODES AND ORDINANCES.
NO PORTION OF THE WORK REQUIRING A SHOP DRAWING or SAMPLE SUBMISSION SHALL
COMMENCE UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT.
ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH REVIEWED SHOP
DRAWINGS AND SAMPLES. SHOP DRAWINGS AND PRODUCT SUBMITTALS ARE REQUIRED FOR
ALL SHOP FABRICATED WORK AS WELL AS SPECIFIED PRODUCTS. THIS WORK INCLUDES,
BUT NOT BE LIMITED TO, STRUCTURAL and DECORATIVE STEEL, WINDOWS and DOORS,
BUILT-IN CABINETRY, HARDWARE, PLUMBING and ELECTRICAL FIXTURES, APPLIANCES AND
EXTERIOR & INTERIOR FINISH MATERIALS.
TOP OF PLATE
TOP OF FLOOR ELEVATION
A8.1
2A8.1
A
B
C
EL.=98.2
EL.=
T.O. PLATE
110'-0"
EL.=
T.O. PLY.
100'-0"
NORTH
234
A
3C
CL
/
SEE SHEET
1 A2.1
D
IBC INTERNATIONAL BUILDING CODE
IRC INTERNATIONAL RESIDENTIAL
CODE
KITCHEN
107
SPRAYED FOAM
PROJECT INFORMATION
LOCATION:
LEGAL DESCRIPTION:
PROJECT DESCRIPTION:
ROOM NUMBERROOM NUMBER
DOOR LETTER
CONSTRUCTION
ASSEMBLY
SHEET NUMBER
BUILDING SECTION
SHEET NUMBER
DETAIL SECTION
SHEET NUMBER
WALL SECTION
SHEET NUMBER
SHEET NUMBER
INTERIOR ELEVATION
00
A9.3
1
A9.1
1
A4.1
1
A5.1
1
ALUMINUM
EVOLVE STRUCTURAL DESIGN
1040 MAIN STREET
CARBONDALE, COLORADO 81623
TELE: (970) 510-0773
KAEGEBEIN FINE HOMEBUILDING
PO BOX 1570
CARBONDALE, COLORADO 81623
TELE: (970) 309-2638
LOT 7, EAGLE PINES SUBDIVISION
INTERIOR RENOVATION
401 EAGLE PARK DRIVE, PITKIN COUNTY, COLORADO
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
0
8
P
M
A0.1
1918
GEN.
INFORMATION
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
PERMIT SET 6/03/19
CVR COVER
A0.1 GEN. INFORMATION
Architectural
D2.1 LOWER LEVEL DEMO PLAN
D2.2 MAIN LEVEL DEMO PLAN
D2.3 UPPER LEVEL DEMO PLAN
A2.1 LOWER LEVEL REFERENCE PLAN
A2.2 MAIN LEVEL REFERENCE PLAN
A2.3 UPPER LEVEL REFERENCE PLAN
A2.4 LOWER LEVEL PLAN - NORTH
A2.5 LOWER LEVEL PLAN - SOUTH
A2.6 MAIN LEVEL PLAN - NORTH
A2.7 MAIN LEVEL PLAN - SOUTH
A2.8 UPPER LEVEL PLAN - NORTH
A2.9 UPPER LEVEL PLAN - SOUTH
A10.1 DOOR, WINDOW & OPENING SCHEDULES
Structural
S0.001 GENERAL NOTES AND TYP. DETAILS
S2.001 FOUNDATION PLAN NORTH
S2.002 FOUNDATION PLAN SOUTH
S2.003 MAIN LEVEL FRAMING PLAN NORTH
S2.004 MAIN LEVEL FRAMING PLAN SOUTH
S2.005 UPPER LEVEL FRAMING PLAN NORTH
S2.006 UPPER LEVEL FRAMING PLAN SOUTH
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
1
2
P
M
D2.1
1918
LOWER LEVEL
DEMO PLAN
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
1/8" = 1'-0"
1 LOWER LEVEL EXISTING/DEMO PLAN
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
1
3
P
M
D2.3
1918
UPPER LEVEL
DEMO PLAN
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
1/8" = 1'-0"
1 UPPER LEVEL EXISTING/DEMO PLAN
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
0
8
P
M
A2.1
1918
LOWER LEVEL
REFERENCE
PLAN
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
PERMIT SET 6/03/19
NORTH
1/8" = 1'-0"
1 LOWER LEVEL REFERENCE PLAN
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
0
8
P
M
A2.2
1918
MAIN LEVEL
REFERENCE
PLAN
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
PERMIT SET 6/03/19
NORTH
1/8" = 1'-0"
1 MAIN LEVEL REFERENCE PLAN
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
0
9
P
M
A2.3
1918
UPPER LEVEL
REFERENCE
PLAN
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
PERMIT SET 6/03/19
NORTH
1/8" = 1'-0"
1 UPPER LEVEL REFERENCE PLAN
NORTH
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
1
2
P
M
A2.9
1918
UPPER LEVEL
PLAN -SOUTH
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
PERMIT SET 6/03/19
1/4" = 1'-0"
1 UPPER LEVEL South
NORTH
CHARLES
CUNNIFFE
ARCHITECTS
COPYRIGHT CHARLES CUNNIFFE
ARCHITECTSC
610 EAST HYMAN AVE.
ASPEN, CO 81611
TEL: 970.925.5590
FAX: 970.920.4557
cunniffe.com
SHEET NO.
JOB NO.
6/
5
/
2
0
1
9
2
:
4
0
:
1
2
P
M
A10.1
1918
DOOR,
WINDOW &
OPENING
SCHEDULES
EA
G
L
E
P
A
R
K
R
E
M
O
D
E
L
40
1
E
A
G
L
E
P
A
R
K
D
R
I
V
E
PI
T
K
I
N
C
O
U
N
T
Y
,
C
O
ISSUE: DATE:
PERMIT SET 6/03/19
INTERIOR DOOR SCHEDULE