Loading...
HomeMy WebLinkAboutPitkin.EH.273510202007 (2019)Bryan Daugherty <bryan.daugherty@pitkincounty.com> Online Form Submittal: Property Sale/Remodel Use Permit Application 1 message noreply@civicplus.com <noreply@civicplus.com>Wed, Jul 31, 2019 at 11:24 AM To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com Property Sale/Remodel Use Permit Application Please Note: Each OWTS System must be submitted individually. If there are additional systems on the property, additional applications are required. Job Parcel ID 2735102007 Physical Address 401 Eagle Park Dr, Aspen CO 81611 Residences 1 No. of Bedrooms 5 Square Footage of each Residence 12674 Purpose of Use Permit Remodel/Addition Lot Lot 7 Block Field not completed. Filing Field not completed. Subdivision Eagle Pines (Section Break) Primary Contact Information Primary Contact First Name Noah Primary Contact Last Name Czech Primary Contact Email Address noahc@cunniffe.com Primary Contact Address 610 E Hyman Ave Primary Contact Phone Number 9709255590 Primary Contact City Aspen Primary Contact State CO Primary Contact Zip 81611 (Section Break) Owner Information Primary Contact is Owner?No Owner First Name Randy Owner Last Name Metz Owner Email Address rmetz@parkmetzlaw.com Owner Mailing Address 329 Main Street Owner City Carbondale Owner State CO Owner Zip 81623 Owner Phone 9703404977 Owner Fax 9709635905 Indicate Preferred Method of Payment Check Payment Contact Email for Debit/Credit Payment rmetz@parkmetzlaw.com (Section Break) Licensed Inspector Information Primary Contact is Licensed Inspector? No Inspector First Name Tom Inspector Last Name Scott Inspector Email Address tjs@hceng.com Inspector Mailing Address 1517 Blake Ave Inspector City Glenwood Springs Inspector State CO Inspector Zip 81601 Inspector Phone Number 9709458676 Inspector Fax Number Field not completed. (Section Break) Uploads Pitkin County Inspection Form 15.Aspen Sanitation.pdf Site Plan 38.Site Plan.pdf Floor Plans 38.Building Plans.pdf Additional Reports, etc.38.Site Plan.pdf Comments or additional information: Thanks for working on this. Let me know if you have any questions. Noah (970)925-5590 noahc@cunniffe.com PLEASE READ BEFORE SELECTING SUBMIT: By selecting SUBMIT, I certify that I am the owner or representative with the legal authority to agree to the conditions of this permit, the above information is complete and accurate, and that I have provided complete and accurate information in all of the documents included in my application package. I acknowledge that this department may revoke any permit I am issued if my application is found to contain any inaccurate, false, or misleading information. Building Permit Instructions If this application is part of a building permit application, please bring a copy of this application to your building Pre-Submittal meeting. To get a copy, either enter your email address to receive a copy of your application, or select "Submit and Print" below. Email not displaying correctly? View it in your browser. D ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) A USE PERMIT INSPECTION FORM 76 Service Center Rd Aspen CO 81611 970-920-5070 Fax 97&920-5077 www.PltklnCoun .com Inspection for Permit Number: 02036 POWU job Address (provide proof ofappliration for an addrass'dthere is arrently no adtlress AtltlressA Ikation ob streec401 Eagle Park Drive Job Cky:N/A Job state:C0 mbzlp TtI Owner owner First N.rr.:1 UDC Eagle Pines LLC owner Last Name: N/A owner corporation Name: N/A owner Mailing Mdrms:250 IMironDrive IOwnercity:Soulh Lake wnerstate:TX 0wnerzip:76092 Owner Phone: Owner Cell Phone:_ Owner Email N/A Permit Contact Contact First Name: Karen I Contact Last Name: Toth onnaa Business Name Koren Toth Realty, Inc. Contact Mailing Address: ontact City: ContaRState: CD Cantaa Zip: I Cornea Phone: (970) 379-5252 1 Contact Cell Phone (970) 379-5252 1 Contact Email: Karen@KarenTodFcom Licensed Inspector Inspector First Name:Tom Inspector last Name: Seou Inspenor Business Name:High Country Engineering Inspector Mailing Address: 1517 JBIake Ave. IIrspector Ctty:Glenwood Springs IInspeaor5tate:CO I lnspeaorzip:81601 Inspector Phone (970)945-8676 Inspector Cell Phone: Inspector Email:tfg@hpeag.eom Inspector's License Number: 20 Parcel ID 273510202007 Legal Description Lot 7 Eagle Pines Subdivision A copYof this inspection will be remitted W Pitkin County Environmental Health Department bythe Licensed systems ImpectorwRhin fA days ofthe inspection regardless of whether the system passes or fails. Questions For Property Owner PRIOR To Inspection: Is the home currently occupied? No How many bedrooms are in the home? 15 If N: How long has it been vacant? N/A RECORDS Were system records available from Pitkin County? Yes If Y: Permit Number 02036 Date offinal approval: 10/31/U4 Was an as -built drawing available? Yes Is the as -built drawing accurate? Yes HIM: Complete and upload a drawing of the system as accurately and possible ❑✓ Describe char a In use differences: No. of bedrooms permitted:0 SITE CONDITIONS Any questions marked FAIL or NO will require correction before an OWTS Use permit is issued. Proper grading, no evidence of erosion: PASS 1 Proper vegetation cover: yes NO evidence of compaction such as heavy machinery or livestock: rN. Proper discharges (no straight pipes): PASS 1 NO evidence of high ground water: No Snow cover is NOT present: No Site Conditions Pau/Fail: PASS TANK(S) TANK TANK TANK Tank Capacity (gallons) 2,000 1,250 Tank Material Concrete Concrete Number ofcompartments One Two Date of last pumping Unknowa Unknown Lids/risers PASS PASS Risers to grade YES YES Riser height T - 0" Y - 0" Riser condition/watertightness Unknoum Unknown Inlet Sanitary T/Baffle PASS PASS Outlet Sanitary T/Baffle PASS PASS Effluent Filter If pan of design) PASS IPASS Condition of Tank Material PASS PASS Tank was pumped for inspection NO NO If y: List Pumping Company N/A N/A If N: Date of last pumping Unknown Unknown Scum level (1st compartment) inches 6" 6" Sludge level (1st compartment) inches 12" 12" Scum level 2nd compartment) inches 6" 6" Judge level 2nd compartment) Inches 12" 12" BackFlow(if pumped) N/A N/A Midtank Baffle PASS N/A Water Tightness PASS 111PASS PUMPS/DOSING SIPHONS Is a pump or dosing siphon present? Yes Ify: Is the pump/dosing siphon function properly. Yes Does the pump/wiring/dosing siphon appearto be in good condition? Yes Is the high water alarm working; both visibly and audibly? NO Pumps/Dosing Siphon Pass/Fail: FAIL SECONDARY TREATMENT Is a secondary treatment unit present? No If Y: Does the unit appear to be in good working condition? N/A Does the owner have a current maintenance contract for the unit? Unkoum Maintenance Provider jUnknown Phone N/A Email N/A Secondary Treatment Pass/Fail: N/A It there is no maintenance contract, a contract most be In place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department ABSORSTION AREA Effluent surfacing? NO Evidence of past surfacing? NO Surface dampness? NO Excessive odors? NO Field location verified by observation ports or probing: YES Liquid in observation port? FNO IfY: Recorded Depth (inches) O Distribution Box or ADV part of original Design? Yes If Y: Is it accessible from grade? NO If Y: Is it level and in good condition N/A Absorption Area Pass/Fail: PASS Any problems withthesystern thatwere notaddressed above? 1. Unable to verify the successful operation of septic tank visual and audible high water alarm. 2. Presence ofpresumed roofdram discharge pipe and irrigation sprinklers at absorption area, noted during inspection. 3. Presence ofpossible spa drain discharge pipe connected to second septic tank, noted during inspection. 4. Unable to locate and inspoetburied distribution box during inspection. List any recommendations for the continued use of thesystem: 1. Recommend evaluation and repair of septic tank visual and audible high water alarm. . Recommend removal of presumed roof drain discharge pipe and irrigation sprinklers from absorption area, per County compliance. . Recommend removal of possible spa dram discharge pipe connected to second septic rank, per County compliance. . Recommend locating distribution box and installing access risers and removable cover to grade, needed for inspection. Were any repairs done as a msuIt of this inspection? If Y: Describe repairs No Additional Notes: Clearly label any pictures and upload them. 171 To the heat of me k-1-cige and trainingthe information collected in this inspection is accurate. 09/25/16 Insp- Date: Save Form for Submittal Reset this form CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 7/ 3 1 / 2 0 1 9 1 1 : 2 0 : 5 8 A M A1.2 1918 SITE PLAN - SEPTIC EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: SITE PLAN - SEPTIC CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 1 2 P M EAGLE PARK REMODEL CVR EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O 401 EAGLE PARK DRIVE PITKIN COUNTY, CO PERMIT SET 05/31/19 ARCHITECTURAL SYMBOLS SYMBOL LEGEND SPOT ELEVATION NEW CONTOUR EXISTING CONTOUR CENTER LINE HIDDEN LINE SETBACK LINE BREAK LINE PROPERTY LINE ROOM NAME ROOM NUMBER REVISIONS KEYNOTE SHEET NUMBER CAST BATTCOMPACTED FILL POROUS FILL UNDISTURBED SOILS CONCRETE BLOCK BRICK STONE GLASS BLOCK STEEL RIGID FINISH WD. FRAMING WD. BLOCKING GLU-LAM PLYWOOD PLAN & SECTION MATERIAL INDICATIONS VICINITY MAP GENERAL NOTES EARTH ROCK CONCRETE MASONRY METAL INSULATION WOOD MATCH LINE PROJECT NORTH TRUE NORTH GROUT, LIGHTWEIGHT CONCRETE ARCHITECTURAL ABBREVIATIONS ZONING & BUILDING CODE INFORMATION SHEET INDEX PROJECT DIRECTORY ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS, AND THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL CONFINE HIS/HER OPERATIONS ON THE SITE TO AREAS PERMITTED BY THE OWNER. SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE SPECIFICATIONS SHALL TAKE PRECEDENCE. UNLESS A WRITTEN DECISION FROM THE ARCHITECT HAS BEEN OBTAINED WHICH DESCRIBES A CLARIFICATION OR ALTERNATE METHOD AND/OR MATERIALS. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON HOW TO PROCEED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE. THE CONTRACTOR SHALL PROVIDE COMPLETE BUILDING SYSTEMS AND COMPONENTS IN COMPLIANCE WITH MANUFACTURERS' REQUIREMENTS AND RECOMMENDATIONS. ALL SEQUENCING, INTERFACE AND COORDINATION WITH OTHER BUILDING TRADES SHALL BE AS REQUIRED FOR COMPLETE, PROPERLY INSTALLED AND OPERATING SYSTEMS AND/OR BUILDING COMPONENTS, AND SHALL MEET OR EXCEED QUALITY LEVELS OF COMMONLY ACCEPTED CONSTRUCTION PRACTICE AND INDUSTRY STANDARDS. CONTACT ARCHITECT WITH ANY QUESTIONS PRIOR TO STARTING WORK. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION, FREE OF DEBRIS AND LITTER, AND SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR EQUIPMENT. EACH SUB-CONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS/HER WORK SHALL REMOVE ALL TRASH AND DEBRIS AS OF RESULT OF HIS/HER OPERATION. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DETERIORATION. FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK. WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER PIPING AND CONDUITS, THE LARGER STUD SIZE OR FURRING SHALL EXTEND THE FULL SURFACE OF THE WALL WIDTH AND LENGTH WHERE THE FURRING OCCURS. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTICS, ECT. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF HIS/HER WORK THAT MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND SHALL NOT ENDANGER ANY OTHER WORK BY CUTTING, EXCAVATING, OR OTHERWISE ALTERING THE TOTAL WORK OR ANY OTHER PART OF IT. ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED IN EXECUTION OF WORK SHALL BE DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON COMPLETION, MATCH SURROUNDING SIMILAR SURFACES. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, A.C. EQUIPMENT, RECESSED ITEMS, AND ALL OTHER ITEMS AS REQUIRED. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 2015 I.R.C. AND ANY REQUIREMENTS BY THE LOCAL BUILDING DEPARTMENT ZONING AR-10 AFF BM BS. B.O. ACCOUS ADJ ALT ALUM APPD APPROX ARCH ASAP BRG BET BLK BSMT BTU BLDG CAB CLG CER CLR ABOVE FINISHED FLOOR ADJACENT ALTERNATE ALUMINUM APPROXIMATE APPROVED BEAM BEARING BETWEEN BLOCK BASEMENT BRITISH THERMAL UNIT(S) BOARDBD BOTH SIDES BOTTOM OF BUILDING CABINET CENTER LINE CEILING CERAMIC CLEAR CJ CF DP DW DN DR EA. EW CLO CLOSET D W COL CONC CONT COORD CTR DEPT DTL DIA, DIM DWG ELECT CLOTHES DRYER CLOTHES WASHER COLUMN CONCRETE CONSTRUCTION JOINT CONTINUOUS COORDINATE COUNTER CUBIC FEET DAMPROOFING DEPARTMENT DETAIL DIAMETER DIMENSION DOWN DRAIN DRAWING EACH EACH WAY ELECTRICAL EL EQ F.O. FP FD FT GA GC GL GRD. HD HP HT ID JT ENGR EXG EXP. EXT. FIN FIXT FTG FDN FURN GAL GALV GYP. GWB HDW HVAC HORIZ HWH INCL INFO INSUL ELEVATION ENGINEER EQUAL EXISTING EXPOSED EXTERIOR FACE OF FINISH FIREPROOF FIREPLACEFPL FIXTURE FLOOR FLOOR DRAIN FOOT, FEET FOOTING FOUNDATION FURNISH GALLON GAUGE GALVINIZED GENERAL CONTRACTOR GLASS, GLAZED GRADE GYPSUM GYPSUM WALLBOARD HARDWARE HEAD HORIZONTAL HORSE POWER HOT WATER HEATER HEIGHT INCLUDE (D) (ING) INFORMATION INSIDE DIAMETER INSULATION JOINT INT INTERIOR HEATING, VENTING, AND AIR CONDITIONING LT MO NA OD d QT R RD RM JCT KWH LAV MFR MATL MTL MAX MECH MED JUNCTION KILOWATT HOUR LAVATORY LIGHT MANUFACTURER MATERIAL MASONRY OPENING METAL MAXIMUM MECHANICAL MEDIC (INE) (AL) MIN MISC NOM NIC NTS OPG OC OPP ORN PTN PERF PERFORATE(D) PENNY (NAILS, ECT.) MINIMUM MISCELLANEOUS NOMINAL NOT IN CONTRACT NOT APPLICABLE NOT TO SCALE ON CENTER OPENING OPPOSITE ORNAMENTAL OUTSIDE DIAMETER PARTITION PLT. PLY QTY PLATE PLYWOOD QUARRY TILE QUANTITY RADIUS ROOF DRAIN ROOM RS ROUGH SAWN RW R RO SQ SS TV TO T UG RCB REF. REFR REINF REBAR REQD SHT SHLV SVF SIM STC SPEC SF RESILIENT COVE BASE RETAINING WALL REFER/REFERENCE REFRIGERATOR REINFORCE ( D) REINFORCING BAR (S) REQUIRED RISER ROUGH OPENING SHEET SHEET VINYL FLOORING SHELV (ES) (ING) SIMILAR SOUND-TRANSMISSION CLASS SPECIFICATION SQUARE SQUARE FEET STD STRUCT SUB SUPPL S4S SUSP TEL TEMP T&G T&B TYP TYPICAL STANDARD STRUCTURAL SUBSTITUTE SUPPLEMENT SURFACED FOUR SIDES SUSPEND(ED) TELEPHONE TELEVISION TOP AND BOTTOM TONGUE AND GROOVE TOP OF TREAD V WH WC WP WT W/ WD UNGL UNFIN VIF VERT VCT WWF WDW W/O UNGLAZED UNFINISHED VERIFY IN FIELD VERTICAL VOLT WATER HEATER WATER CLOSET WATERPROOF WEIGHT WELDED WIRE FABRIC WINDOW WITH WITHOUT WOOD ACOUSTICAL ARCHITECT (URAL) BFF BELOW FINISHED FLOOR CL, DISHWASHER LAM LAMINATE (D) OPH OPPOSITE HAND STL STEEL TEMPERED AS SOON AS POSSIBLE FLR STAINLESS STEEL VINYL COMPOSITION TILE U.N.O.UNLESS NOTED OTHERWISE UNDERGROUND ARCHITECT STRUCTURAL ENGINEER CONTRACTOR ZONING INFORMATION: APPLICABLE CODES: DIMENSIONS: A. ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE OF DRAWINGS. B. ALL DIMENSIONS ARE TO FACE OF STUD or FACE OF CONCRETE U.N.O. C. ALL EXTERIOR STUDS TO BE 2x6 U.N.O. ALL INTERIOR STUDS TO BE 2x4 U.N.O. ALL INTERIOR STUD WALLS & CEILINGS BETWEEN LIVING SPACES SHALL HAVE 3 1/2 " SOUND ATTENUATION BATTS UNLESS THERMAL INSULATION IS CALLED FOR. (WHEN APPLICABLE) INTERIOR ELEVATION WINDOW NUMBER CHARLES CUNNIFFE ARCH. 610 E. HYMAN AVE. ASPEN, COLORADO 81611 TELE: (970) 925-5590 FAX: (970) 920-4557 BUILDING TYPE AND OCCUPANCY: TYPE V / GROUP R3 OCCUPANCY FULLY SPRINKLERED PROVIDE FIRE SPRINKLER PROTECTION THROUGHOUT THE BUILDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING THE DRAWINGS AND OBTAINING THE PERMITS FOR THE FIRE SPRINKLER SYSTEM. THE FIRE SPRINKLER SYSTEMS SHALL MEET THE REQUIREMENTS OF ALL APPLICABLE CODES AND ORDINANCES. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING or SAMPLE SUBMISSION SHALL COMMENCE UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH REVIEWED SHOP DRAWINGS AND SAMPLES. SHOP DRAWINGS AND PRODUCT SUBMITTALS ARE REQUIRED FOR ALL SHOP FABRICATED WORK AS WELL AS SPECIFIED PRODUCTS. THIS WORK INCLUDES, BUT NOT BE LIMITED TO, STRUCTURAL and DECORATIVE STEEL, WINDOWS and DOORS, BUILT-IN CABINETRY, HARDWARE, PLUMBING and ELECTRICAL FIXTURES, APPLIANCES AND EXTERIOR & INTERIOR FINISH MATERIALS. TOP OF PLATE TOP OF FLOOR ELEVATION A8.1 2A8.1 A B C EL.=98.2 EL.= T.O. PLATE 110'-0" EL.= T.O. PLY. 100'-0" NORTH 234 A 3C CL / SEE SHEET 1 A2.1 D IBC INTERNATIONAL BUILDING CODE IRC INTERNATIONAL RESIDENTIAL CODE KITCHEN 107 SPRAYED FOAM PROJECT INFORMATION LOCATION: LEGAL DESCRIPTION: PROJECT DESCRIPTION: ROOM NUMBERROOM NUMBER DOOR LETTER CONSTRUCTION ASSEMBLY SHEET NUMBER BUILDING SECTION SHEET NUMBER DETAIL SECTION SHEET NUMBER WALL SECTION SHEET NUMBER SHEET NUMBER INTERIOR ELEVATION 00 A9.3 1 A9.1 1 A4.1 1 A5.1 1 ALUMINUM EVOLVE STRUCTURAL DESIGN 1040 MAIN STREET CARBONDALE, COLORADO 81623 TELE: (970) 510-0773 KAEGEBEIN FINE HOMEBUILDING PO BOX 1570 CARBONDALE, COLORADO 81623 TELE: (970) 309-2638 LOT 7, EAGLE PINES SUBDIVISION INTERIOR RENOVATION 401 EAGLE PARK DRIVE, PITKIN COUNTY, COLORADO CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 0 8 P M A0.1 1918 GEN. INFORMATION EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: PERMIT SET 6/03/19 CVR COVER A0.1 GEN. INFORMATION Architectural D2.1 LOWER LEVEL DEMO PLAN D2.2 MAIN LEVEL DEMO PLAN D2.3 UPPER LEVEL DEMO PLAN A2.1 LOWER LEVEL REFERENCE PLAN A2.2 MAIN LEVEL REFERENCE PLAN A2.3 UPPER LEVEL REFERENCE PLAN A2.4 LOWER LEVEL PLAN - NORTH A2.5 LOWER LEVEL PLAN - SOUTH A2.6 MAIN LEVEL PLAN - NORTH A2.7 MAIN LEVEL PLAN - SOUTH A2.8 UPPER LEVEL PLAN - NORTH A2.9 UPPER LEVEL PLAN - SOUTH A10.1 DOOR, WINDOW & OPENING SCHEDULES Structural S0.001 GENERAL NOTES AND TYP. DETAILS S2.001 FOUNDATION PLAN NORTH S2.002 FOUNDATION PLAN SOUTH S2.003 MAIN LEVEL FRAMING PLAN NORTH S2.004 MAIN LEVEL FRAMING PLAN SOUTH S2.005 UPPER LEVEL FRAMING PLAN NORTH S2.006 UPPER LEVEL FRAMING PLAN SOUTH CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 1 2 P M D2.1 1918 LOWER LEVEL DEMO PLAN EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: 1/8" = 1'-0" 1 LOWER LEVEL EXISTING/DEMO PLAN CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 1 3 P M D2.3 1918 UPPER LEVEL DEMO PLAN EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: 1/8" = 1'-0" 1 UPPER LEVEL EXISTING/DEMO PLAN CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 0 8 P M A2.1 1918 LOWER LEVEL REFERENCE PLAN EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: PERMIT SET 6/03/19 NORTH 1/8" = 1'-0" 1 LOWER LEVEL REFERENCE PLAN CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 0 8 P M A2.2 1918 MAIN LEVEL REFERENCE PLAN EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: PERMIT SET 6/03/19 NORTH 1/8" = 1'-0" 1 MAIN LEVEL REFERENCE PLAN CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 0 9 P M A2.3 1918 UPPER LEVEL REFERENCE PLAN EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: PERMIT SET 6/03/19 NORTH 1/8" = 1'-0" 1 UPPER LEVEL REFERENCE PLAN NORTH CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 1 2 P M A2.9 1918 UPPER LEVEL PLAN -SOUTH EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: PERMIT SET 6/03/19 1/4" = 1'-0" 1 UPPER LEVEL South NORTH CHARLES CUNNIFFE ARCHITECTS COPYRIGHT CHARLES CUNNIFFE ARCHITECTSC 610 EAST HYMAN AVE. ASPEN, CO 81611 TEL: 970.925.5590 FAX: 970.920.4557 cunniffe.com SHEET NO. JOB NO. 6/ 5 / 2 0 1 9 2 : 4 0 : 1 2 P M A10.1 1918 DOOR, WINDOW & OPENING SCHEDULES EA G L E P A R K R E M O D E L 40 1 E A G L E P A R K D R I V E PI T K I N C O U N T Y , C O ISSUE: DATE: PERMIT SET 6/03/19 INTERIOR DOOR SCHEDULE