HomeMy WebLinkAboutPitkin.EH.264335402007 (2019)Page | 1
Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2643-354-02-007
OWTS Use Permit #: 0088.2019.POWU
Date Issued: 12/19/19
Issued By: Bryan Daugherty
Expiration Date: 12/19/20
Owner(s): Bogaert Family Trust
Property Address: 800 Eppley Dr
Legal Description:
Licensed Inspector: Carla Ostberg
Inspection Date(s): 11/12/19, 11/15/19 & 12/11/19
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit 2 compartment concrete tank
2 compartment concrete tank
1000 gallons
1000 gallons
Secondary Treatment Unit
Absorption Area Chamber bed 2711 ft2
Other System Components
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re -evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 96015 Date of Issuance: 5/18/05 Date of Final Approval: 7/7/05
# of Bedrooms or fixtures served by OWTS: This system was designed to serve 5 bedrooms.
Operational Status: According to the inspector’s observation on site, the system appeared to functioning as designed.
The tanks were watertight and in good working condition. The field area did not appear to have any signs of failure.
Inspector Recommendations: Risers should be added to bring the 1st tank manhole lids to grade for access, pump the
septic tank.
Department Recommendations: Continue maintenance as needed.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
Bryan Daugherty <bryan.daugherty@pitkincounty.com>
Online Form Submittal: Property Sale/Remodel Use Permit Application
1 message
noreply@civicplus.com <noreply@civicplus.com>Mon, Dec 16, 2019 at 11:19 AM
To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com
Property Sale/Remodel Use Permit Application
Please Note: Each OWTS System must be submitted individually. If there are
additional systems on the property, additional applications are required.
Job Parcel ID 264335402007
Physical Address 800 Eppley Drive
Residences 1
No. of Bedrooms 4
Square Footage of each
Residence
5315
Purpose of Use Permit Remodel/Addition
Lot R-78
Block 11
Filing Starwood Eleven
Subdivision Starwood
(Section Break)
Primary Contact Information
Primary Contact First Name Carla
Primary Contact Last Name Ostberg
Primary Contact Email
Address
carla.ostberg@gmail.com
Primary Contact Address 33 Four Wheel Drive Road
Primary Contact Phone
Number
9703095259
Primary Contact City Carbondale
Primary Contact State Colorado
Primary Contact Zip 81623
(Section Break)
Owner Information
Primary Contact is Owner?No
Owner First Name Family Trust
Owner Last Name BOGAERT
Owner Email Address Field not completed.
Owner Mailing Address 800 Eppley Drive
Owner City Aspen
Owner State CO
Owner Zip 81611
Owner Phone Field not completed.
Owner Fax Field not completed.
Indicate Preferred Method of
Payment
Debit/Credit Card
Payment Contact Email for
Debit/Credit Payment
carla.ostberg@gmail.com
(Section Break)
Licensed Inspector Information
Primary Contact is Licensed
Inspector?
Yes
(Section Break)
Uploads
Pitkin County Inspection
Form
800 Eppley Drive Inspection Form.pdf
Site Plan 800 Eppley Drive OWTS Inspection Packet.pdf
Floor Plans 800 Eppley_Existing Floor Plans.pdf
Additional Reports, etc.2019-11-19_800 Eppley Dr_Permit Drawings.pdf
Comments or additional
information:
additional file shows remodel of studio to become bedroom with
bath
risers to be installed once in stock
PLEASE READ BEFORE SELECTING SUBMIT:
By selecting SUBMIT, I certify that I am the owner or representative with the legal
authority to agree to the conditions of this permit, the above information is complete
and accurate, and that I have provided complete and accurate information in all of
the documents included in my application package. I acknowledge that this
department may revoke any permit I am issued if my application is found to contain
any inaccurate, false, or misleading information.
Building Permit Instructions
If this application is part of a building permit application, please bring a copy of this
application to your building Pre-Submittal meeting. To get a copy, either enter your
email address to receive a copy of your application, or select "Submit and Print"
below.
Email not displaying correctly? View it in your browser.
Owner's Name:
Address:
Parcel Number:
Inspection Date:
Pitkin County Systems Inspector License Number:
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
Is the home currently occupied?YES NO
If NO, how long has the home been vacant?
How many bedrooms are in the home?
RECORDS:
Were system records available from Pitkin County?YES NO
If YES:Permit number: ___________
Date of Final Approval: _________
# of bedrooms permitted: ___________
Was an as-built drawing available?YES NO
Is the as-built drawing accurate? YES NO
If NO:
SITE CONDITIONS:
Proper grading, no evidence of erosion?PASS FAIL
Improper vegetative cover?NO YES
Evidence of compaction such as heavy machinery or livestock?NO YES
Improper discharges such as straight pipes?PASS FAIL
Evidence of high ground water?NO YES
Snow cover present?NO YES
Any question marked FAIL will require correction before an OWTS Use permit is issued.
If secondary treatment is used, who is the
maintenance provider?
Complete a drawing of the system on last page of this form as accurately as
possible.
Email:
Inspector's Name:
Business Name:
A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by
the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system
passes or fails.
Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
Inspection form for continued use of an existing OWTS
Website:
Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
Phone Number
Page 1
TANK:
Tank capacity gallons gallons gallons
Tank material
# of compartments
Date of last pumping
Lids/risers in good condition
Risers to grade
Riser height
Riser condition/watertightness
Inlet sanitary T/baffle
Outlet sanitary T/baffle
Effluent filter (if part of design)
Condition of tank material
Tank was pumped for inspection
If YES, list the pumping company
If NO, when was the last pumping
Scum level (1st compartment)inches inches inches
Sludge level (1st compartment)inches inches inches
Scum level (2nd compartment)inches inches inches
Sludge level (2nd compartment)inches inches inches
Backflow (if pumped)
Midtank baffle
Watertightness
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present?YES NO
If YES, is the pump/dosing siphon functioning properly?PASS FAIL
Does the pump/wiring/dosing siphon appear to be in good condition?PASS FAIL
Is the high water alarm working, both visible and audible?PASS FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present?YES NO UNKNOWN
If YES, does the unit appear to be in good working condition?YES NO
Does the owner have a current maintenance contract for the unit?YES NO UNKNOWN
Maintenance Provider:_______________________________________Phone:________________________
ABSORBTION AREA:
Effluent surfacing?PASS FAIL
Evidence of past surfacing?NO YES
Surface dampness?NO YES
Excessive odors?NO YES
Field location verified by observation ports or probing:Ports Probing
Liquid in observation port?NO YES
If YES, record depth:inches
Distribution Box or ADV part of original design?YES NO UNKNOWN
If YES, is it accessible from grade?YES NO
Is it level and in good condition?PASS FAIL
If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A
copy of the contract must be submitted to Pitkin County Environmental Health Department.
Tank 1 Tank 2 Tank 3
Page 2
Any problems with the system that were not addressed in the inspection checklist?
Please list any recommendations for the continued use of the system:
Were any repairs done as a result of this inspection?NO YES
If YES, please describe the repairs.
Licensed Systems Inspector Signature:
Additional Notes:
To the best of my knowledge and training, the information collected in this inspection is accurate as of
__________________, 20____.
Clearly label any pictures and attach them to this form.
Page 3
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
December 14, 2019
Tanja Kelley
tanja@caroldopkin.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
800 Eppley Drive
Pitkin County, Colorado
Tanja,
As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit
inspection at 800 Eppley Drive, Aspen, Colorado on November 12 and 15, 2019. The legal description of
the 2.16-acre property is Lot R-78, Block 11, Starwood Eleven, Starwood Subdivision.
The permit and record drawing were provided by Pitkin County Environmental Health Department (Parcel
ID #2643-354-02-007). The subject OWTS consists of two 1000-gallon concrete septic tanks in series.
Effluent gravity flows to two distribution boxes and then to a large gravelless chamber bed with five rows
of 10 ‘Standard’ Infiltrator® chambers and 5 rows of 11 ‘Standard’ Infiltrators® for a total of 105 chambers
and 1969 square feet of infiltrative area. Individual Sewage Disposal System Permit 96015 documents
this system. The system was sized to accommodate 5 bedrooms. The permit received final approval
on June 18, 1996.
The septic tanks are located off the southeast corner of the residence. At the time of our first visit to the
property, only the second septic tank in the series was accessible. Work was done by Altitude Septic to
access the first septic tank in the series, including cutting down a mature tree that was directly over one
of the manhole lids on December 11, 2019. A camera was also run through sewer lines between the
septic tank and there was standing water in the pipes indicating inadequate fall from one tank to another
and/or settling of the sewer line between the tanks. While it does not appear to be causing issues
currently, it could create a problem in the future.
All inlet and outlet tees were present and levels in the tanks were normal at the time of the inspection.
The first septic tank is scheduled to be pumped on December 18, 2019 by Altitude Septic. The second
septic tank in series was pumped in 2016 by B&R Septic.
Please note the photograph provided in the Pitkin County file. It shows the location of the septic tanks
and distribution boxes relative to the beginning of the soil treatment area (STA) and chambers.
Landscaping, including planting of mature trees and creation of a “stream” (dry at the time of our
inspection) in locations that appear to be directly over the STA. These features have existed for some
time and the OWTS appears to be functional without obvious signs of malfunctioning or failure; however,
it should be noted that trees in the area of the OWTS components can lead to root intrusion and water
should not be routed over OWTS components.
The distribution boxes were not accessible from grade at the time of our inspection and could not be
inspected. We walked the STA and found no evidence of surface saturation or failure at the time of our
inspection. There are very mature trees over the OWTS components, including the STA, specifically to
the on the south side. This evaluation is not a guarantee of future system performance. This inspection is
good for one year.
Required Repairs:
• Bring all manhole lids to grade. (SCHEDULED FOR JANUARY WHEN RISERS ARE IN STOCK)
• Pump 1st septic tank in series. (SCHEDULED FOR DECEMBER 18, 2019)
Recommendations:
• Install effluent filter on outlet tee of second septic tank in series. If installed, this filter must be
cleaned annually, or as needed.
• Monitor levels in septic tanks. Standing water in sewer lines between septic tanks and
landscaping features, including trees, over OWTS components may cause future issues.
A completed OWTS Use Permit Application must be submitted to the Pitkin County Environmental
Health Department. Applications must be submitted to Pitkin County Environmental Health Department
electronically. The following is the link to the required OWTS Use Permit Application:
https://pitkincounty.com/FormCenter/Environmental-Health-18/Property-SaleRemodel-Use-Permit-Applicat-
70
Within the application, you must attach the Inspection Form where “Pitkin County Inspection Form” is
requested, the OWTS Inspection Packet where “Site Plan” is requested, and Floor Plans where “Floor Plans”
are requested. Floor plans may be hand drawn and must represent number of bedrooms or potential
bedrooms in the residence.
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector’s expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11044ITC Exp. April 2020
Clean out access to second septic tank in series during first visit
View of STA view of septic tank lid / stream / and trees
Tree roots over outlet side of 1st septic tank Tree removed
Inlet side of 2nd tank outlet side of second tank (see baffle)
Inlet side of 1st tank / developed scum layer outlet side of 1st tank
800 Epp l ey Drive Legend
800 Eppley Dr
100 ft
N
➤➤
N
Y.
pF< 22 :.•',.5& 05: 181;€ .F+ TT rvQii r"Ird ,"W1RONMENT•AL NC.Af..TH QEP"FTN,ENT P
APf .:ATION FOR iNDtViUUAL SEWAG� QISPC -SYSTEM
a� 136 8. Galena St., Aspon ColorgAo 81611
Phone 970-920,5070ax 070-920-5039
Parrs t 1 Parcel ID 0 a co 4:5 �'i 7 � � L4 6-a-LF� }
POMIt PW Mew Inatellatlon (vf Repair { } Remodel { ] Erviaegancy Use { }
Name of QVVNEfq _ _—
Gwnee!s Muting Address C EA6.,_ff6---."--
Auslness Rhona: HonriePhona:
Nameo[Agartt µ 'i�1+eG�j•';l�,tl�►O P 1l1 rC G LWS - ---
Agent's Wilinsg Addres3 _ 1 !a 6" tt 4-+- �,T f-t t4e
Business Phone:
Cony of permit to tea seentt to: owmar ( ) Agent( )Soth (�-r
Street Ad+;ross i�oo eFFI_C . z tV `
Legal Dasalpt!on, Lot R-TF ,flack ,&ubdirsi�n i�t�Cws,7t tz- -�r`
Size of lot: /J.tW acre$ Type of proposed structura: 61 ?; i_ a of bldg. er•valopa;
Total areallMi ng space (sq. ft): it of Bedrooms, offices and sImliaf site :moms:
Gsre!.ker klnq : Attached oetached of Bedrooms offloos and similar sir � rooms: _I}O rAZ _�� —Il
Fu u t" �a lap r�c,?i f tom` 1 '�¢ d CCf ,f.� id ._ ..,
VL'a:er:( ;Priaate wail{ )Spring( )Stresm (11tommunity1public (Name of System)
Is Proof of Adoqucte lh'ater Attached ? ( )Yes( ) No
Has this protect been approved by PEfkin County ? [ ] Yes (-rN '
is a raav of tra flocs p'an allaCh6d { fpQuir9d } ? (- Yes )No _ ......
App11:-dr,3M1 for 8n InCMajal FdWi;s d:lresaE syslCn is nEreoy rwbmittml. The undem*md stknowicdges that the above je-w Radon Ls Vue and t-�1at 181;a IrlfpfTn Jiian will
i-wx'idata the 2Fplicmion and any aubsvqu"I; permit. Isauance Of the permit dint not imply the approvst of any other pennt required tar eo^.strvCtion ptirsvxnt to Pkktn County
code3. No cmatruct+on fray bo undartaken until ag approvfls and permits hive been obtefncd. The owner assurnea all reepwidbititlra to rasa ^t failure or Inadequacy of t}1ii
syvc-n
a Signature of applicant Cat`
For depasimeIt use b?1sw
P.,E BM f FOR LND Vij]3JAL3F �.P3E-W&_Q�ALrSXaTLM
py�*�n Cr!tsrj� Ysree.t3 A d mysi ba submitted end aaoraved iP writlnal --
Sepa. to >< �x7paGty; t7 gsflona AOorpticn area;
3 e 7r, �Ut"�4-,r� y,, &�
� �❑ _r e
Li;�.�' P @R.. .� t�tJ Jkt-�'s'n""t".,r'�c--�D ►��v t��
An inspection Is required prior to backfi11 of any component of the distributlon system,
design by =ngincer Required ? ( ) Yes (1/j No Ail plans and specifications of tho ongineer must be followed. Any Gkariges must be appfovod it)
writing and tre ertgirsCrr must rertify Ilia final instafialion to the Environmental Health Dapartmf:nt in writing.
+ Permit approval by' Al Uale
Pfanf 8ntl s?er cati�rs of Via proposed ird v east aqa isposal system eve be viewsd end are wnaldorod �aWa-1 ry. A a f Is hereby granted to Iris owner of
Ina agnt to petiomi V`0 or'IC indiftled in aeaar¢ with the prWrl County ISIDS Ra [on in nffed at the time 3'�+�l e of is. T1113 pom-ill iK•cortte! 1nv8lIC 6 mOnth6 !turn If IC data
Cwi
eras Lie parmrt wxa issue"] unless system crnsw ha. =mmeneed of an Woniion h beerl approved'ki we Wg by Na I)i-Wrnent.
rr r
Installer: l� •� - L ,
As - Suitt drawings must be Inc ludo a with this permi afore tie final app vat wlil he Iva Lod.
Final Inspection Approval: Data: gale serueSled: IF '__
Ogle Pd : ` r t?eceip *'. �S � Received by:��� lntarmattort conspls,to: S f
1l�Ntli'- pA.�t�t.�v!
V
a�l (e (rt • �tnrn, j Q. �-�ll���r� �0 , tsti_
�&L4,w y�
0 a 1, T P,
4fl.p
0
err•. G'! !�� � r
4
�'dAt,--k
Aspen 1 Pitkin Environmental Health Department
Contact Log Sheet
' {
Name eo -u
.S Etn
Parcel ID
street address
❑ate Received:
Application
q-,2 3
Fee
` -.-23 - q
Pere test
- soil profile
z elL
water Quality
[
site plan
Y� 4�
Water Quantity
p�
House floor plan a 3
Date Person Spoken -0
Comments 1 Action to be Taken
initials
S!-a 3 ~941 4u 5 4rt
; k Ike f
r4 ro ' �
`�lnru�aocL . BBC
IN
5-1-1&
Fin
• a r� .Ti i
■ .t r � r �
4 � �
have- & CQ.,e tuba- rn
L{ T ff ! T h
U3i<< AFC d
r,
x
l
Name Bogaert
ASPENIPITKIN ENVIRONMENTAL HEALTH DEPARTMENT
ISDS DESIGN REQUIREMENTS
DEPARTMENT USE ONLY
Permit # _
Parcel ID # 2645-354-02-007
House Siz 5115 (75 gpd, 100 gpd, or 130 gpd)
Number of Bedrooms, Lofts, Offices, Similar Rooms, Main House 5
Number of Bedrooms, Lofts, Offices, Similar Rooms, Caretaker unit 0
Average Daily Waste Flow 750 # bedrooms X 2 peoplelbr X 75
State Review Required? no
Perc Rate 60 (T)
Design Flo w (Q) _ # bedrooms X 2 people/bedroom X gpd X 1.75
Q= 1750
Absorption Area (A= QI5 X SQRT)
Inn
A = 2711.088 sq- ft- of absorption area required
151 infiltrator units without reduction
A maximum 30% reduction is allowed for use of deep gravel or gravelless chambered system.
1897,762 sq.ft. with reduction � ov - 5 y x 3
105 infiltrator units with reduction At Y 5 y '/ y
Type of system: []Absorption trenches []Absorption bed [] Gravelless chambers
[]Dry well []Seepage Pit []Pumping Chamber
Is an Engineer -Designed System required? no
yes _ reason:
Minimum tank capacity 2000 gallons
SETBACK FROM WELL
# of feet = 160
Remember: 8 feet of additional distance for each 100 gal Ion slday of design flow over 1,000 gallonslday
should be added unless an RPE can verify that it is not necessary to prevent contamination.
APPROVED FOR ISSUE BY:
SYSTEM INSTALLED BY:
DATE OF FINAL INSPECTION REQUEST:
FINAL INSPECTION BY:
DATE.
DATE:
Printed on Recycled Paper
,� �" ,� sit=- • - � - - � .. �-�- -
I
r�.
y
��
YA
v
�.o Ya GOG�
fw'v j o r1 .
7"
1996 '
EWAONM NTA EALTM
AspEN I pfTwN J
I
5 KpWS Wr-rH� Io ��
I*
E
MA Y— 2—So6 T"LI 1 3 : 20
P - 0 2
=ir•Pw[7RTH-pAWLAH G80TECHNICAL, INC.
April 29, 1996
1kfhn Bogaert
P o Box 1166
%pen, Colorado 91612
S02a hold 154
Glenwood Whisk CO A'M'+
Fax 971) 945-8494
lhnne 974 41S•7M
Job No. 196 I.7
litiblect: Percolation Testing, Proposed BagaOrt Residence, Lot R79, StArwcxui
Pitkin County, Colorado.
tear Mr. Boga.ert:
As requested by River Studio Architects, Hepworth-Pawlalc Owtechdoal, 1W. parf*emed
percolation testing at the subject site. The work was conducted in accordance with our
►L?rr.Ment for geotechnical engineering services to you dated April 19, 1946.
l'hree percolation test holes and a profile pit were excavated OR Apnl 24, 19% weft'
ruhher tired backhoe, at the locations shown on Fig. I. Percolation test holes were hand
dug in the bottom of the backhoe pits. The holes were soaked on April 24, 1996 and
protected from freezing overnight. The subsoils exposed is the profile pit consisted of
;i*rxzut 1 foot of fill materials and 1 foot of topsoil overlying silty sand and gravel with
cobbles and scattered boulders to 4 feet in size. The profile pit was excavated to A depth
c>l' Sv;t feet below existing ground surface. No free water was observed in the pit and the
subsoils were slightly moist to moist. Results of a gradation analysis performed nn 3
~ample of the natural subsoils collected from the profile pit are presented On Fig 2
The percolation tests were conducted on April 25, 1996 and the test results are
summarized on Table 1. The percolation rates vaned from about 20 to 90 minutes rer
inch The higher percolation rate of test hole P-3 appears to be due to the hole being
excavated in the transition between fill and native soils. The average percolation rate of
the two other tests is about 60 minutes per Inch. used on the subsoils exposed and the
I)ercolation test results, the tested site is suitable for a conventional infiltration system
'rhe disposal area should be based in the natural soils below the fill and topsoil Rnd
+,versizM due to the slower percolation rates.
I t' you have any questions or we may be of further assistance, please call Our oPFce
sincerely,
HEPWORTH - PAWLAK
.I ord Z . d o0r., P
Reviewed by; SLP
30 INC
��po Rbq'�r��
297Q7 �A
l I A1kmk'�^ i
Attachments
cc. River Studio Architects - Attn: Bill Lipsey
MESSAGE DISPLAY
TO Betsey Kipp CC eho
From: Lee Cassin
Postmark: Apr 24,96 11:54 AM
Subject: _Reply----
- --------------------------------------------------------------
Reply text:
From Lee Cassin:
I'm not very creative. -I think a barn is not, but they should be
warned they can't ever add a caretaker unit in it, and a house is.
I'm still inclined to go with a garage or carport that's attached is.
But I can be overruled by claims of being a bureaucrat
Preceding message:
From Betsey Kipp:
What was the final decision? Does the 20 foot setback from a
dwelling/occupied building include a barn? Thanks.
MAY--
+ t
APPROXIMATE SCALE ,N s
r 40.
LINE ULI)II
/PRqMM
0 SETBACX I
LINES
PROBBoO
E (STING }
1- 3
oil
� r 1
s_
n �• �' >
1 � �
r 1 �
BORING W
BORINGW
i s RESIDEN E
r~
1
l �
ti
• 90ftING � � . _ d
I "I' B
Lar R-
P-t
Psrcv#ion e
Pit itirP1 PI-i$ 1 I
Pat
1
Ip
HEPWORTH-PAWLA!lK LOCATION OF EXPLORATORY BORINGS F%- I
I96 I T� GEOTECHNICAL, maANDPERCOLATION PITS
,�� mow. ��.........�..�.
�r �iy�•� rr r
H E PWO RTH - PAWLAK
GEOTECHNICAL. INC.
MRYLi 1 3 22 P. $a
HEPWORTH-PAWLAK GEOTECHNICAL, INC.
TABLE I
PERCOLATION TEST RESULTS
JOB N4� 196 178
HOLE No HOLE DEPTH
LENGTH OF WATER DEPTH WATER DEPTH
END OF
DROP IN
WATER
AVERAGE
PERCOLATION
(INCHES)
INTERVAL AT START OIL AT
(MIN) INTERVALINTERVAL
VEL
RATE
(INCHES) (INES!
(INCHES)
lMiNJINCHI
P.1 -�— 93112
30 10 2114
314
8 114 2 112
314
2 112 7 314
314
4D •►ti
P r 63 314
38 11 14 314
114
j
10314 10 114
112
10114 10
114u-
P 3 62
15 11 114 9 114
2
8 114 8 1/2
314
B 112 7 314
314
7 314 7 114
112
f
refi8 13114 11114
2
11 114 10 112
314
hales were hand dug in the bottom of backh" pits and soaked on April 24, 1225,
rnF• , • ;r +1 11 were
Note: Pe .04mosi
rmen freezing overnight. Testing was concluded on April 25, 1226.
�0
10
s- 0 kr-
p--
ARR. 22.1�396 3: 12PM STe�mWOOD HOME OWNERS , .. NO.671 P.2.....�.�
STARWOOD WATER DISTRICT
R.O Box 629
Aspen. Colorado 81612
TO WHOM IT MAY CONCERN
FROM: Julia Johnston, Secretary
Starwocd Water District
DATE: April 22, 1996
RE: Water Service
This is to confirm that the Starwood Water District will supply
water to Tract R-78, 5tarwood Subdivision.
If there are any questions, please call Bill or Julia Johnston,
l 925-8939.
Alf
832‐R‐13‐002
Awl o
SECOND FLOOR PLAN a
RNER STUDIO ARCHITECTS
tws.e .hpsipMi
4I4 M. MILL MILL 3) ASPk'M, COl3 RAW,,
81 4
303
!)10NE: 03 9SS3).
HtS: 9SSdf ]i
.NERAL NOTES
,LL TYPE LEGEND
noa«w
BOGAERT HOUSE
SECOND FLOOR PLAN
Aml 1
DRAWING ISSUANCE INDEX
ID
01
NAME
PERMIT SUBMITTAL
ISSUED DATE
11/19/19, 11:22 AM
STEVEN
WILSON
402127
STA T E O F COLO
R
A
D
O
L
I
C
E
NSED AR C H I TECT
COPYRIGHT
PROJECT NO:
DRAWN BY:
FORUM PHI LLC
DATE OF PUBLICATION
A-101
FLOOR PLANS
11/19/19
RL/MG
1919.00
Aspen CO 81611
800 Eppley Dr.
264-335-402-007
FOR UMPHI
Aspen:
715 West Main Street, #204
Aspen, Colorado 81611
Carbondale:
36 N. 4th St.
Carbondale, CO 81623
forumphi.com
p: 970.279.4157
f: 866.770.5585
11/19/19