HomeMy WebLinkAboutPitkin.EH.264723200001 (2020)
ONSITE WASTEWATER TREATMENT SYSTEM (OWTS)
CONSTRUCTION PERMIT
76 Service Center Rd· Aspen, CO · 81611
Phone: 970.920.5070 Fax: 970.920.5374
Permit #: 0003.2020.POWT Parcel ID #: 2647-232-00-001
Permit Issued: NEW REPAIR REMODEL/ADDITION TANK ONLY FIELD ONLY AMENDMENT
Owner(s): Glenn Russell
Property Address: 1144 Capitol Creek Rd
Legal Description:
Size of Lot: 38 Acres Detached Accessory Unit: YES NO
Size of Building: 1000 Sq. Ft. Size of Accessory
Unit: Sq. Ft.
This system will serve the 2 bedroom CDU, main home is served by another system.
Designed By: CBO, Inc Project #: C1446 Dated: 1/12/20
Phone #: 970-309-5259 Mailing Address:
Fax #: Email Address: Carla.Ostberg@gmail.com
Perc Rate: .8 LTAR (sand) Profile Hole Depth: 8’ Depth to Groundwater or
Bedrock: 6.5’
Minimum Tank Capacity: 1000 gallons Minimum Absorption
Area:
375 ft2
Permit Conditions:
This OWTS Construction Permit is approved on the condition of compliance with the engineer design as submitted with the application and the
specifications cited above. Changes must be approved by this Department and the engineer prior to construction.
This system will consist of a 1000 gallon, 2 compartment tank with a an Orenco pump system installed in the 2 nd
compartment. The pump will pressure dose a sand filter bed. The bed will be 10’x37.5’, 3’ minimum secondary s and, then
10” of gravel with three 1.5” PVC laterals with 5/32” orifices downwards every 3’; landscaping fabric will be placed on top o f
the gravel before final topsoil cover. Observation ports must be installed at each corner of the bed. Field area must
maintain minimum setback for 100’ to both the well and river.
This Permit must be kept on-site during installation. The engineer must do a final inspection of the installation and submit an "as -built" letter to this
Department within 30 days of the final inspection, unless a longer period of time has been agreed upon, in writing. This Department must also be called
for the final inspection with a minimum of 48 hours notice.
Minimum horizontal distances between components of the system and physical features shall conform to the requirements of the Pitkin County OWTS
Regulation.
This Permit is conditioned upon the property owner(s) providing for regular inspection, cleaning, and maintenance of the syst em by qualified personnel, in
accordance with the manufacturer's recommendations and the requirements of the Pitkin County OWTS Regulation. Issuance of this OWTS Construction
Permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail. Issuance of
this permit does not imply compliance with Pitkin County building and/or land use regulations, nor guarantee issuance of building and/or land use permits.
THIS PERMIT IS EXPRESSLY CONDITIONED UPON COMPLIANCE WITH ALL REQUIREMENTS OF THE PITKIN
COUNTY OWTS REGULATION, INCLUDING BUT NOT LIMITED TO THOSE CONDITIONS SPECIFIED ABOVE.
Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is
hereby given to the property owner(s) to perform the work indicated in accordance with the Pitkin County OWTS
Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced.
An "as-built" drawing must be submitted and approved by EH before final approval of the system will be issued.
Issued By: Bryan Daugherty, REHS Date: 4/29/20 Expires: 4/29/21
Installer: License #: Reactivation Authorized by:
Final Approval Issued By: Date: New Expiration Date:
EH
1/30/2020 Pitkin County Mail - Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application
https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1657099381497039217&simpl=msg-f%3A16570993814…1/3
Bryan Daugherty <bryan.daugherty@pitkincounty.com>
Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application
noreply@civicplus.com <noreply@civicplus.com>Wed, Jan 29, 2020 at 2:25 PM
To: schuyler.clay@pitkincounty.com, ehapps@pitkincounty.com
Septic (OWTS) Construction/Repair Permit Application
Job Parcel ID 264723200001
Physical Address 1144 Capitol Creek Road
System Type OWTS (Septic)
Type of Permit New System Construction Application
Residences 1
No. of Bedrooms 2
Lot Field not completed.
Block Field not completed.
Filing Field not completed.
Subdivision Field not completed.
Is this a multi-family
structure?
No
Lot Size 38 acres
Living Area Square Footage 1000 SF net
(Section Break)
Uploads
Site Plan SITE ACTIVITY ENVELOPE PLAN _ Layout.pdf
Building Floor Plans A-101 PROPOSED PLANS _ Layout.pdf
Septic Soil Report Field not completed.
System Design C1446 OWTS Design Packet 1 12 20.pdf
Additional Reports, etc.Field not completed.
(Section Break)
Primary Contact Information
Primary Contact First Name Scot
Primary Contact Last Name Broughton
1/30/2020 Pitkin County Mail - Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application
https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1657099381497039217&simpl=msg-f%3A16570993814…2/3
(Or Company Name)
Primary Contact Email
Address
sbarchitectsco@mac.com
Primary Contact Address Box 4096
Primary Contact Phone
Number
(970) 927-0552
Primary Contact City Basalt
Primary Contact State CO
Primary Contact Zip 81621
(Section Break)
Primary Contact Information (If other than Owner)
Primary Contact is Owner?No
Owner First Name Glenn
Owner Last Name (Or
Company Name)
Russell
Owner Email Address gedwardrussell@gmail.com
Owner Mailing Address 5809 E. Sopris Creek Rd.
Owner City Snowmass
Owner State CO
Owner Zip 81654
Owner Phone (918) 706-8010
Owner Fax Field not completed.
Indicate Preferred Method of
Payment
Check
Payment Contact Email for
Debit/Credit Payment
sbarchitectsco@mac.com
(Section Break)
Designer Information
Primary Contact is Designer?No
Designer First Name Carla
Designer Last Name Ostberg
Designer Phone Number (970) 309-5259
Designer Email Address carla.ostberg@gmail.com
Designer Mailing Address 33 Four Wheel Drive Rd.
1/30/2020 Pitkin County Mail - Online Form Submittal: Septic (OWTS) Construction/Repair Permit Application
https://mail.google.com/mail/u/0?ik=c2c72bb885&view=pt&search=all&permmsgid=msg-f%3A1657099381497039217&simpl=msg-f%3A16570993814…3/3
Designer City Carbondale
Designer State CO
Designer Zip 81623
(Section Break)
PLEASE READ BEFORE SELECTING SUBMIT:
By selecting SUBMIT, I certify that I am the owner or representative with the legal
authority to agree to the conditions of this permit, the above information is complete
and accurate, and that I have provided complete and accurate information in all of
the documents included in my application package. I acknowledge that this
department may revoke any permit I am issued if my application is found to contain
any inaccurate, false, or misleading information.
Building Permit Instructions
If this application is part of a building permit application, please bring a copy of this
application to your building Pre-Submittal meeting. To get a copy, either enter your
email address to receive a copy of your application, or select "Submit and Print"
below.
Email not displaying correctly? View it in your browser.
33 Four Wheel Drive Road
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
January 12, 2020 Project No. C1446
Jennifer and Glenn Russell
c/o Scot Broughton
sbarchitectsco@mac.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
1150 Capitol Creek Road
Pitkin County, Colorado
Scot,
CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The property is located outside in Old Snowmass, in an area
where OWTSs and wells are necessary. The legal description of the property is as follows: Section: 3
Township: 9 Range: 86 TRACT OF LAND IN SECS 3 & 4-9-86 CONT 38.964 AC M/L DESC BY M/B 407
PG 05 BK 586 PG 701
Parcel ID: 2645-041-00-007
EXISTING CONDITIONS
The existing main residence on the property is served by an existing OWTS. The OWTS serving the
main residence was inspected and received an OWTS Use Permit prior to the last property transaction.
See attached inspection report and permit.
A 2-bedroom caretaker dwelling unit (CDU) is proposed. The CDU will be served by a separate OWTS.
A private well, located to the south of the residences and north of the creek, serves the residences. The
well is located greater than 50-feet from the proposed septic tank and greater than 100-feet from the
proposed soil treatment area (STA).
Capitol Creek bisects the property. The creek is greater than 100-feet from any proposed OWTS
component.
The proposed STA will be located west of the gravel driveway and north to northwest of the proposed
CDU. The proposed STA is a relatively flat open field covered by native grasses.
SOILS
The subsurface was investigated on May 2, 2019 by digging two soil profile test pit excavations (Test Pits). A
visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1
The materials encountered in the Test Pit #1 consisted of moist, medium brown loamy sand with cobbles 4-
inches to 2.0-feet in diameter to a maximum depth explored of 6.5-feet. No bedrock or groundwater was
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 2
encountered. There was some indication of mottling close to grade, which we do not believe to be
caused by high seasonal groundwater; however, we placed a hydrometer in the Test Pit to monitor
groundwater conditions.
The materials encountered in the Test Pit #2 consisted of moist, medium brown loamy sand with cobbles 4-
inches to 2.0-feet in diameter to a maximum depth explored of 3.5-feet. No bedrock or groundwater was
encountered. Excavation stopped due to the presence of utilities in this area.
A tactile analysis of the soils was taken from Test Pit #1 at 3-feet below grade. The soil formed a ball,
but no ribbon. Soil structure grade was moderate, shape was single-grain, and consistence was loose.
Soil texture was gritty.
Base soils are Soil Type 1, Loamy Sand. More than 35% rock was present in Test Pit #1; therefore, the
soils are classified as Soil Type R-0. A pressure dosed, over-excavated, unlined sand filter.
Groundwater levels should be verified May-July and any time prior to construction of the STA. If any
groundwater is observed, this office must be contacted. A minimum of 3-feet of sand filter material
(Secondary Sand) will be used. A long term acceptance rate (LTAR) of 0.8 gallons per square foot
will be used to design the OWTS.
Stake marks Test Pit #1 location Beginning of digging
Backfill Test Pit #1
Page 3
Sieved sample
Test Pit #2 (abandoned after 3.5’ due to present of utilities)
DESIGN SPECIFICATIONS
Design Calculations:
2 bedrooms x 75 GPD/person x 2 ppl/bedroom = 300 GPD
300 GPD / 0.8 gal/SF (pressure dosed, unlined sand filter) = 375 SF
The caretaker dwelling unit will include 2-bedrooms. A design flow of 300 gallons/per day will be used to
design the OWTS.
For the purposes of this OWTS design, Benchmark Elevation as top of plywood floor of the CDU has
been established as 100’ (7297.5’). CBO Inc. should be notified of any discrepancies or problems with
grade elevations of proposed components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert Min. 98’ (7295.5’)
Infiltrative Surface Min. 100’ (7297.5’)
A new 4-inch diameter SDR-35 sewer line with a double-sweep clean out and minimum 2% grade to the
septic tank must be installed.
The system installation will include a 1000-gallon, two-compartment Valley Precast concrete septic tank
with an Orenco® Biotube Pump Vault and an Orenco® PF3005 pump in the second compartment of the
septic tank. The floats should be set to dose approximately 50 gallons each pump cycle, allowing
Page 4
approximately 2 gallons of drain back after each pump cycle. The control panel for the pump must be
located within line of sight of the septic tank. We recommend Valley Precast out of Buena Vista be
contracted for start-up of the pumping system. The pump must be capable of design flow rate of 24.4
gallons per minute (GPM) and total dynamic head of 11.8 feet.
The 1.5-inch diameter pump line must maintain a minimum 1% slope for drain back to the septic tank
after each pump cycle. In this case, with the relatively flat topography, the pump line may need to
exit the septic tank rather than the riser.
Effluent will be pressure dosed through a 1.5-inch diameter pump line to an over-excavated, 10’ x 37.5’
unlined sand filter with a minimum of 3-feet of sand filter material. Sand filter material must be clean, coarse
sand, all passing a screen having four meshes to the inch. The sand must have an effective size between
0.15 and 0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting ASTM 33, for concrete
sand, with three percent or less fines passing 200 mesh sieve may be used. A gradation of the sand
media must be provided.
Laterals will be connected with a 1.5-inch diameter level manifold. Laterals used to disperse the effluent
must be surrounded by washed coarse screened gravel or crushed stone (minimum 6-inches below and
minimum 2-inches above laterals). All of the gravel or stone must pass a 2 ½-inch screen and must be
retained on a ¾-inch screen. Laterals must be 1.5-inches in diameter with 5/32-inch diameter orifices
facing down, spaced 3.0-feet on center (OC). We recommend Orenco® Orifice Shields be installed on
the laterals at each orifice. Laterals will begin 2-feet from the edges of the filter, with 3-feet between each
lateral. Each 1.5-inch diameter lateral must end in a sweeping ell facing up with a ball valve for flushing.
A soil separation fabric should be placed over the gravel layer followed by approximately 1-foot of topsoil or
other suitable soil able to support vegetative growth.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Valley Precast Item # 1000T-2CP-HH 1000-gallon, top seam, 2-
compartment concrete
septic tank with high-
head pump
Pump Orenco® PF300511 ½ HP
120 Volt
Biotube ProPak Pump
Package
Orenco® Vault, Filter, Control Panel
(demand dose)
Tank Risers and Lids Orenco® Double-walled PVC Risers and
Lids (24” diameter)
Orifice Shields Orenco® 1.5 inch diameter (33 total)
Flushing Assembly Orenco® 1.5” diameter (2) 45° or 90° long sweep only
(3 total)
Construction must be according to Pitkin County Onsite Wastewater Treatment System Regulations,
the OWTS Construction Permit provided by Pitkin County Environmental Health Department, and
this design.
Page 5
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS
CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
PERMIT APPLICATION INSTRUCTIONS
The application must be submitted electronically.
Link to the Wastewater Treatment page: https://pitkincounty.com/248/Wastewater-Treatment
Click “Septic (OWTS) Construction/Repair Permit Application”
More information can be obtained from Pitkin County Environmental Health Department 970-920-5438 or
970-920-5076.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
Page 6
1-17-2020
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The property owner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in the OWTS. Loading from a water softener should
not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical
room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
Provide positive drainage away from OWTS components and soil treatment area, as necessary.
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
installer should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working.
Please call with questions.
Sincerely,
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo A. Baylosis, PE
Pump Selection for a Pressurized System - Single Family Residence Project
Russell CDU / 1150 Capitol Creek Road
Parameters
Discharge Assembly Size
Transport Length
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
1.25
15
40
1.50
None
2
6
40
1.50
3
35.5
40
1.50
5/32
3
5
None
0
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity
0.68
36
24.4
3
0.5
3.9
gpm
gpm
%
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport
Loss through Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
4.2
0.5
0.0
0.1
0.1
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line
Vol of Manifold
Vol of Laterals per Zone
Total Volume
1.6
0.6
11.3
13.5
gals
gals
gals
gals
Minimum Pump Requirements
Design Flow Rate
Total Dynamic Head
24.4
11.8
gpm
feet
0 5 10 15 20 25 30 35 40
0
50
100
150
200
250
300
Net Discharge (gpm)
PumpData
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
115/230V 1Ø 60Hz, 200V 3Ø 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1/2HP
230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
m0
M c—
� Z Z
m O
oZC
rr: O
1
n WCO PO cn
o TW ivCC v
�' o O om(n m
m c 5 (n m
mCL -4v �� G)C cNn �Z
cQ (D Z zCD I II -
@ CD CD O
cc pcn O 1
�,
Q((D=
D CD
O
O 00 p
M Q
N
W
N
O
\ I
I
D mo10 =
>znp0 VJ
O °x C, 0 1>1
mm�
r D1Az
T`TJ mocm
1 N ai�mm IyF
- 1 c �c<�
O �8 M-
O /A m O z -0 6, \,
(D � ^ V� � mzp0
C--) l / (D O D n
Z C) 0)O°�O
O 6 z�Oo I O
3 0 vm 1.
CD `G M °mm� m
(D /� Am Dmv T
O CD VI Anon I N I \
Orx�
O m0—m
A E (D��>z r
Q 0
nz�=
0-)o Q 0 =1w-0 I Z
=p �z
cD m
Dm; I
CCKm
O
O D �
mz= C
Dmm —
m ,xw
C= c
z CA
� C
O �
� o m
m _
z
m � /
r cf)
r �
\ z
O
X
\ Cmn
m� rn
z
ono 0
m
(D CD &
�((C)
cT Q
a �_
c 1
C �J Q p Asa
C
S
(D
1
11,
E_
777
_
\\
2
ccr cr
/
0
Ef/
\
Cl
/
/ PIS)
ƒ 6
;ozm0
m
Woo>
>za�
o
to
\ 0 \ 0 \
aoo
>ZZ
m�of
a
c$
�2
2w
20
0
�> \ k
@
wm<
m
</
+ �
a
<
2
PM
zƒ O
O$
mq
�/
>M
2
>
r
\»° �
\a °\ 2
\�
^>: 2 m
z %
\ 2
\< « m ?
�/ \�
» m
\
%
�
- T
i
-
o cm Mtn
„gym nz
D W (/� m
0 W W
M. 0< 0
m r m mo
0
_
��
D A D
o O O
� (OQ� (�
_2ON <A
ZOm DD
O� in
<
T1 TI*z
v�i
r Z n
W GG2
CD CD
N�� ��
mmD�D
mm�D
(Q �" m
^
1tJ CO
omcn
m Z o
(n�Nc)
2 W (�
�zrm
D TI T7
o
c0 p
<IA
mop2
�GDD
v UNi v <
IA0g
�60�
OGZZ
— corm
O
o
(nc)jov
OZT0
mm0
03CCO
CO
Z
0
w>
V (mAm
�0
rn>
D�
o_
Z N
Z
00
0
0
•:
N
o
,[1 r : ',
N
on
(ism:;°'
z
z.
10
a
m
Cn
N.
D
o z
DF
w
w
zzD
Or
zD
< nZ n
m 0(n r
G)o
zm 2
Z Z-
n n -n
D D
> G)
N
N
2=r
mm�
Mm
m G
ZD
(n cn mm
D
-0 r
�
K
m
o
TO
N
0
^�
"
1=
O,
TZ
N
D r D
I D
m
CD
m�
D
Z o
D D
2
N
..
3 G 0
N
0(n
0 0 0 N
Z n D D o Z
C7 CD
ncu N
Zm
M0
D
Z0w
o G)200XT:-4
O m
;0�
N
D
N p„SmrU]
Z7 (D
-nZ
2
DS 0momm�
Z < (n m
� O_ O
0)
W -0A
(n m
zo z GD^(n
0') O CL ci
mp
p
o
r
co D�nZK(n
DC
(D
m
��rOZC
D
m
r
z 0 2 w m
�Om�
r D0
n
Z
Om O5(rn=�m
2
�
z m * ;o C
O
0
(/>—m6C
2= m w z
mc�'� z
0 N_ m
m�
or-
0 D '2
Z -0
T m D
D� 0(n
OZ
m
G) -0
m Z
C n
�cn
m0
m
m �� OC
0 D
Z
mD n� 00
jZ
Z
N
-i
0
m"' m0
cmi
=
"'n
D
z
m
N
0
x
ilia
Ci
D
o�
-I
r
z
�.
_
o
_
D
IIIII
O� -n Z
W N
O
Z
-
-
D
r- m O? =
o
x m
p
X
r
m
Om*D
��
=-IIIII
N z O 2 G)
r D
G) m
TI
Z
rNO
D— m p
D
p G
o�
r
-111I
0� m 0 m
z0(n�
m r
�
2
m
pip p
v �_
DZm�
m
c
G)
m ca
�
0 m
To
m
D
Cr CD Q Q o
-
m
0
m
a c
O
� W
O
m
m
CC
W
O
TI O
DEPTH - FEET
_ �■f co 00 �I O Ui A W N O 0 c 2> < v N p
o O�D00 �cn —D cn m
,max ��n0� ZmZ� mm0 0
Z�>�D 0oo Dp0 Z
c) w ZO O 0 0 m
c
v o v wm �0U)nm mF �mM
m ° o o O Z� �m>m z0O r-(ncco
00 XpDmD O?� 00-
s�v " mz c� OT �c0�� �� �(nz
�� np 0p p m 112z zD Cl)0 ii ooc�
CD w
�u oO
M
° CD
O> m>mp
z W?m K0 M
� m��D m 00vNczm Dz
—(0QCD ZO G�00 m Dom cnD p�
° M M ��c Zo- m� X
3 s°a) co y0� z �o� 00� w
Nn m >NW 0 �QO> Zm o0
w mT�pZ m
0 0 0 � ° n n
m z cn �O K 0 00
Z�r Cl)0 mz
n
w�> T� �m
0 o m
c -< ,i mm
m 0z
0 m
m p
p n
D
z
2
N
(N
O
N C/)
O r
;u
0 0
CD
W = cn
C r A m
o
Cl)mz m
F �_- cn
� m X � c T
1 cn m K
�o N Z moCD z
m
CD
° 0a) _ 0c �O� n)
r- c D e r-
3 �_ o m z-0
N n m m CnmD
nm N p -0�
n p� E CD O� Z
�oCD p
rn 0 wCL 0 _
CD mDz
MMD
mmr
;umr
0 0 -n
T O C
M
0 cn
D Z
m� nG)
m
p 00
Q X
O -n
D
jc
p r
�
�
� III
a a=1
-III—I
IF
om =1lli l
ti
op
�m
D
m D
r
III=III
IIIIIII
"I1
IIII
cn O Oi), Din D0=66 �o
=
< mD m cnD mD ��< cn
0- CD (D o mC) mc'i D 5mcn nD
Q° 1_ p= m m= �Dr c<
p -0 p m m
p�`� N yo D cflo D X o00
0 p m< o G D r 0
CO O O n r p
W m
r 0
CC
cD
cD
A
O ■
TI O
A
SHEET NO.
SHEET TITLE
PROJECT DATA
COPYRIGHT
ISSUED FOR
GENERAL
All designs ideas, arrangements and plans indicatedby these drawings and specifications are the propertyand copyright of the Architect and shall neither beused on any other work nor be used by any otherperson for any use whatsoever without writtenpermission
Written dimensions shall take precedence over scaleddimensions and shall be verified at the job site. Anydimensional discrepancy shall be brought to theattention of the Architect prior to commencement ofthe work
DRAWN BY:
CHECKED BY:
ISSUE DATE:
SHEET:
AS-103
PROGRESS SET: 1/29/20
SC
O
T
B
R
O
U
G
H
T
O
N
A
r
c
h
i
t
e
c
t
s
,
L
L
C
PO
B
o
x
4
0
9
6
/
2
3
2
8
0
T
w
o
R
i
v
e
r
s
R
d
.
,
U
n
i
t
3
/
B
a
s
a
l
t
,
C
O
8
1
6
2
1
[t
]
9
7
0
/
9
2
7
-
0
5
5
2
[
f
]
0
5
5
4
/
[
e
]
s
b
a
r
c
h
i
t
e
c
t
s
@
s
o
p
r
i
s
.
n
e
t
ALFRED N BEADLESTON
SCOT BROUGHTON
6/15/09
7 of 26
SBA
1" = 30', 1:1950.8966
SITE ACTIVITY ENVELOPE
PLAN
11
4
4
C
A
P
I
T
O
L
C
R
E
E
K
C
D
U
11
4
4
C
A
P
I
T
O
L
C
R
E
E
K
R
O
A
D
Sn
o
w
m
a
s
s
,
CO
HAYED
MEADOW
ACTIVITY ENVELOPE HAYED
MEADOW
100.0' STREAM SETBACK
EXISTING FENCE
& GATE
EXISTNG
PUMP HOUSE
EXISTNG
DECK &
HOT TUB
ACITVITY
ENVELOPE
EXISTING SCREEN VEGETATION
NEW PARKING
NEW OWTS
FIELD & TANK
EXIST'G PROPANE
TANK
EXST'G POWER
POLE & METER
EXISTNG HOUSE
OWTS TANK & FIELD
EXISTING RANCH
SERVICE ROAD &
GATE
CAPITOL CREEK
CAPITOL CREEK
PROPERTY LINES 83' 11.06" W
415.47'
CAPITOL CREEK ROAD
RAIL FENCE LINE
7290
7295
7300
PROPERTY LINE
100.0' FR
O
N
T
S
E
T
B
A
C
K
NEW COTTONLESS
COTTON WOOD/ASPEN TREES
NEW BLUE SPRUCE
EXISTING BLUE SPRUCE
EXISTING COTTON WOOD
ASPEN MIX
100.0' FR
O
N
T
S
E
T
B
A
C
K
FRONT SETBACK
45' SETBACK VARIANCE - RESOLUTION
0
5
-
2
0
1
0
50' SETBACK VARIANCE - RESOLUTION
0
5
-
2
0
1
0
76' SETBACK VARIANCE - RESOLUTION 8
8
-
2
9
17' SETBA
C
K
V
A
R
I
A
N
C
E
-
R
E
S
O
L
U
T
I
O
N
1
2
-
2
0
1
9
SCALE: 1" = 30'1ACTIVITY ENVELOPE
SCALE: 1:1950.8966 2OVERALL SITE PLAN
ENLARGED SITE PLAN INSET BELOW
SHEET NO.
SHEET TITLE
PROJECT DATA
COPYRIGHT
ISSUED FOR
GENERAL
All designs ideas, arrangements and plans indicatedby these drawings and specifications are the propertyand copyright of the Architect and shall neither beused on any other work nor be used by any otherperson for any use whatsoever without writtenpermission
Written dimensions shall take precedence over scaleddimensions and shall be verified at the job site. Anydimensional discrepancy shall be brought to theattention of the Architect prior to commencement ofthe work
DRAWN BY:
CHECKED BY:
ISSUE DATE:
SHEET:
A-101
PROGRESS SET: 1/29/20
SC
O
T
B
R
O
U
G
H
T
O
N
A
r
c
h
i
t
e
c
t
s
,
L
L
C
PO
B
o
x
4
0
9
6
/
2
3
2
8
0
T
w
o
R
i
v
e
r
s
R
d
.
,
U
n
i
t
3
/
B
a
s
a
l
t
,
C
O
8
1
6
2
1
[t
]
9
7
0
/
9
2
7
-
0
5
5
2
[
f
]
0
5
5
4
/
[
e
]
s
b
a
r
c
h
i
t
e
c
t
s
@
s
o
p
r
i
s
.
n
e
t
ALFRED N BEADLESTON
SCOT BROUGHTON
6/15/09
15 of 26
SBA
1/4" = 1'-0"
PROPOSED PLANS
11
4
4
C
A
P
I
T
O
L
C
R
E
E
K
C
D
U
11
4
4
C
A
P
I
T
O
L
C
R
E
E
K
R
O
A
D
Sn
o
w
m
a
s
s
,
CO