Pitkin.EH.246717401002 (2018)
Page | 1 Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 www.aspenpitkin.com/EHNR Parcel ID #: 2467-174-01-002 OWTS Use Permit #: 0036.2018.POWU Date Issued: 08/03/2018 Issued By: Kurt Dahl Expiration Date: 08/03/2019 Owner(s): William D Harmon Jr and Kathy Fasel Property Address: 38 Booth Ln Legal Description: Lot 33 Holland Hills Licensed Inspector: Carla Ostberg Inspection Date(s): 4/25/2018 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Fiberglass 2-compartment septic tank 1000 gallons Secondary Treatment Unit Absorption Area Rock and Pipe soil treatment trenches (SB-2 pipe) 200’ total length in 4 trenches, 600 ft2 Other System Components OWTS Use Status: In use at the time of the inspection. Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 90033 Date of Issuance: 08/22/1990 Date of Final Approval: 10/15/1990 # of Bedrooms or fixtures served by OWTS: This system was designed for up to 3 bedrooms. Operational Status: The inspector indicates the system was functioning properly at the time of inspection and there is no evidence of failure. Inspector Recommendations: Pump septic tank prior to transfer of property. Department Recommendations: Annual maintenance Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. 00A.20W, Povit D- 6- . - ..jt t z 4. Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT APPLICATION 76 Service Center Rd Aspen, CO 81611 hUp:ltpitkincounty.com/248/Wastewater-Treatment Application for Continued Use of an Existing OWTS Parcel ID# (available from the Pitkin County Assessor's Office 970.920.5160ora[ http:tipitkinassessor.org/assessortsearch.asp �� 6 Purpose of Use Permit (iPROPERTY TRANSACTION u ©REMODEL/ Property Address: 8 Booth Lane, Basalt, CO Lot: Block: Filing: Subdivision: 33 olland Hills Residences: Other # of Bedrooms: fixtures/uses: Property Owner(s)': Email Address: Kathy Fasel, William D Harmon arfase@sopris.net Owner's Mailing Address: City, State, Zip; P O Box 212 Basalt CO 81621 Home Phone: Business Phone: (970) 927-4196 (970) 379-4365 'Contact information must be provided for the owner signing this application. Primary Contact Person/Applicant(if not owner):Kattly Fasel Company: ContatttAppOEafit Mailing Address: LP O Box 212 City, State, Zip: Basalt Co 81621 Cell Phone: (970) 379 4365 Business Phone: Fax Number: Email Address: icaria.ostberg@gmail.com Indicate Preferred Method of Payment ■ Check drediUOehit Cash 71 Licensed Systems Inspector. Phone Number: Email Address: Fax Number. Carla Ostberg (970) 309-5259 carla.ostberg@gmail.com Mailing Address: Ci State Zi : 3 Four Wheel Or Rd Carbondale 181623 PLEASE READ BEFORE SIGNING: I certify that the above information is complete and accurate and that I have provided complete and accurate information in all of the documents Included in my application package. I acknowledge that this department may revoke any permit I am Issued if my application is found to contain any inaccurate, false, or misleading informs'". Effective Date 1/12/2017 CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 IN cell) 970-309-5259 office) 970-704-0484 carla.ostbergQ mail.com May 20, 2018 Kathy Fasel and Bill Harmon harfaseC7a sopns net Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 38 Booth Lane Pitkin County, Colorado Kathy and Bill, As requested, CBO Inc. performed an Onsite Wastewater Treatment System (OWTS) Use Permit inspection at 38 Booth Lane, Basalt, Colorado on April 25, 2018. The legal description of the 0.54-acre property is Lot 33, Holland Hills at Basalt. The permit and record drawing were provided by Pitkin County Environmental Health Department (Parcel ID # 2467-174-01-002). The subject OWTS consists of one 1000-gallon, two -compartment fiberglass septic tank. Effluent gravity flows to four SB-2 trenches, each 3' wide by 56' long. Individual Sewage Disposal System Permit 90033 documents this system. The system was sized to accommodate 3 bedrooms. The permit received final approval on October 15, 1990. The septic tank is located near the southeast side of the residence. No clean out was observed between the house and the septic tank. The septic tank is accessible via two 6-inch diameter riser pipes, which is documented on the record drawing from Pitkin County. While we typically recommend better access to the septic tank, we do not know what type of lids are on the fiberglass tank and if better access is feasible. We were able to observe both inlet and outlet tees through the 6-inch diameter access ports. We typically recommend an effluent be installed on the outlet tee; however, this limited access does not allow the installation, in addition to making thorough inspection and cleaning more difficult. The septic tank was pumped by RotoRooter in 2016. There is normal accumulation of solids in the septic tank. With the limited access, we were only able to measure solids directly under the 6-inch access pipes. There was greater than 1-foot of sludge on the inlet side of the septic tank and approximately 1- foot under the outlet. We recommend pumping prior to transfer of the property. We walked the approximate soil treatment area (STA) which is comprised of SB-2 trenches. We have enclosed specifications for SB-2 pipe. No inspection ports were observed in the STA. According to the drawing provided by Pitkin County, the trenches are connected with a manifold of sorts and not a distribution box. We found no evidence of surface saturation or failure at the time of our inspection. This evaluation is not a guarantee of future system performance. This inspection is good for one year. Recommendations: Pump septic tank prior to transfer of the property. This report and a completed OWTS Use Permit Application must be submitted to the Pitkin County Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health Department electronically. The following are links to the required OWTS Use Permit Application and Checklist. Application: h4p'/(www.ptkincounty.comlDocutnentCenterlHomeNiew(621 Application Checklist: enterlHomeNiew/620 All questions regarding permit submission can be directed to Pitkin County Environmental Health Department, 970-920-5070. Disclaimer. This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector's expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 110441TC Exp. April 2020 looking toward house. B Tf I M Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form �� Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone:970-920-5070 Fax: 970-920-5374 Website: Ihttp:llpitkincounty.conV248/wastewater-Treatment Inspection form for continued use of an existing OWTS Owner's Name: Address: Parcel Number: Inspection Date: Inspector's Name: Business Name: Phone Number Email: Inspector License Number: 017 Pitkin County Systems A copy of this inspection report will be remitted to Pitkin County Environmental Health -Department by the Licensed Svstems Inspector within 60 days of the inspection regardless of whether the system passes or falls. QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied? YES ❑NO If NO, how long has the home been vacant? How many bedrooms are in the home? 13 If secondary treatment is used, who is the maintenance provider? In/a RECORDS: Were system records available from Pitkin County? ®' YES ®NO ISDS Permit 90033 If YES: Permit number:0 Date of Final Approval: lOctober 15 1990 # of bedrooms permitted:0 Was an as -built drawing available? AYES ❑ NO Is the as -built drawing accurate? YES ®NO If NO: Complete a drawing of the system on last page of this form as accurately as possible. Any question marked FAIL will require correction before an OWTS Use permit is issued. SITE CONDITIONS: =- Proper grading, no evidence of erosion? - PASS - -- FAIL ISTA in irrigated _] Improper vegetative cover? L!.j NO W YES yard j Evidence of compaction such as heavy machinery or livestock? ' NO YES Improper discharges such as straight pipes? [F]PASS[_]FAILEvidence of high ground water? 0_ NO ❑ YES Snow cover present? 0 NO ® YES Page 1 Effective Date 1/1212017 TANK: Tank 1 Tank 2 Tank 3 Tank capacity 1,000 gallons gallons gallons Tank material fiberglass if of compartments 2 Date of last pumping 2016 Lids/risers in good condition Pass Select One Select One Risers to grade Yes Select One Select One Riser height 2- Riser condition/watertightness ok Inlet sanitary T/baffle Pass Select One Select One Outlet sanitary T/baffle Pass Select One Select One Effluent filter (if part of design) N/A Select On Select One Condition of tank material Pass Select One Select One Tank was pumped for inspection No Select One Select One If YES, list the pumping company If NO, when was the last pumping Scum level (1st compartment) 1 inches inches inches Sludge level (1st compartment) 12 inches inches inches Scum level (2nd compartment) 0 inches inches inches Sludge level (2nd compartment) 12 inches inches inches Backflow (if pumped) Select One Select One Select One Midtank baffle Select One Select One Select One Watertightness Pass Select One ISelect One PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present? YES RAIL If YES, is the pump/dosing siphon functioning properly? be in PASS FAIL ❑PASS ❑FAIL Does the pump/wiring/dosing siphon appear to good condition? Is the high water alarm working, both visible and audible? ❑PASS __ FAIL SECONDARY TREATMENT: Is a secondary treatment unit present? DYES ' NO ❑UNKNOWN ] If YES, does the unit appear to be in good working condition? YES HYES NO Does the owner have a current maintenance contract for the unit? NO ❑UNKNOWN Maintenance Provider: nia Phone: If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. ABSORBTION AREA: Effluent surfacing? Evidence of past surfacing? Surface dampness? Excessive odors? Field location verified by observation ports or probing: Liquid in observation port? If YES, record depth: Distribution Box or ADV part of original design? If YES, is it accessible from grade? Is it level and in good condition? NO LJYES NO ❑ YES NO ❑ YES NO I IYES YES NO UNKNOWN YES NO 'ASS FAIL Page 2 Effective Date 1/12/2017 ted access to septic tank via 6-inch pipes (documented on record drawing). e unable to view inside septic tank beyond 6-inch access are not aware of the type of lids on the fiberglass tank; therefore, better access may not be Please list any recommendations for the continued use of the system: pump septic tank prior to transfer of property Were any repairs done as a result of this inspection? El NO ❑ YES To the best of my knowledge and training, the information collected in this inspection is accurate as of May20 201a �. pBwh W^� hYGfis OflGq Licensed Systems Inspector Signature: ICarla Ostberg ; oa.: znsasm,,:am mm SB2 piping used in STA (see enclosed specifications) distribution of trenches appears to be via a manifold of sorts rather than a distribution box no access to STA Clearly label any pictures and attach them to this form. Page 3 Effective Date 111212017 38 Booth Lane Basalt, CO 81621 Finished Heated Livable Area: 2,251 sq ft