HomeMy WebLinkAboutPitkin.EH.247113201004 (2018)Page | 1
Pitkin County Environmental Health Department
Onsite Wastewater Treatment System (OWTS) USE PERMIT
Permit for Continued Use of an Existing OWTS
76 Service Center Road, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
www.aspenpitkin.com/EHNR
Parcel ID #: 2471-132-01-004
OWTS Use Permit #: 0027.2018.POWU
Date Issued: 06/12/2018
Issued By: Kurt Dahl
Expiration Date: 06/12/19
Owner(s): John H. Wheeler IV and Stephanie C. Wheeler
Property Address: 23050 Frying Pan Rd
Legal Description: Lot 4 Wheeler Family Subdivision
Licensed Inspector: Carla Ostberg
Inspection Date(s): 06/05/2018
SYSTEM INFORMATION
Components Type Capacity/Size
Primary Treatment Unit Concrete two-compartment septic
tank
1000 gallons
Secondary Treatment Unit
Absorption Area Seepage Pit Unknown
Other System Components
OWTS Use Status:
In use at the time of the inspection. Not in use at the time of the inspection.*
*If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate
evaluation of the system.
System Records:
Permit #: 87040 Date of Issuance: 08/19/1987 Date of Final Approval: 08/19/1987
# of Bedrooms or fixtures served by OWTS: This system was designed for 3 bedrooms.
Operational Status: The inspector indicates the system is functioning properly at the time of inspection and there were
no indications of failure. The OWTS record for this system could not be located but information on the permit was
located from the OWTS log.
Inspector Recommendations: Excavate and reset settled portion of sewer line between house and septic tank.
Department Recommendations: Annual maintenance.
Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and
on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department
that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions.
Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible
failure.
Owner's Name:
Address:
Parcel Number:
Inspection Date:
Pitkin County Systems Inspector License Number:
QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION:
Is the home currently occupied?YES NO
If NO, how long has the home been vacant?
How many bedrooms are in the home?
RECORDS:
Were system records available from Pitkin County?YES NO
If YES:Permit number: ___________
Date of Final Approval: _________
# of bedrooms permitted: ___________
Was an as-built drawing available?YES NO
Is the as-built drawing accurate? YES NO
If NO:
SITE CONDITIONS:
Proper grading, no evidence of erosion?PASS FAIL
Improper vegetative cover?NO YES
Evidence of compaction such as heavy machinery or livestock?NO YES
Improper discharges such as straight pipes?PASS FAIL
Evidence of high ground water?NO YES
Snow cover present?NO YES
Any question marked FAIL will require correction before an OWTS Use permit is issued.
If secondary treatment is used, who is the
maintenance provider?
Complete a drawing of the system on last page of this form as accurately as
possible.
Email:
Inspector's Name:
Business Name:
A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by
the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system
passes or fails.
Onsite Wastewater Treatment Systems (OWTS) Use
Permit Inspection Form
Inspection form for continued use of an existing OWTS
Website:
Pitkin County Environmental Health Department
76 Service Center Rd, Aspen, CO 81611
Phone: 970-920-5070 Fax: 970-920-5374
Phone Number
Page 1
TANK:
Tank capacity gallons gallons gallons
Tank material
# of compartments
Date of last pumping
Lids/risers in good condition
Risers to grade
Riser height
Riser condition/watertightness
Inlet sanitary T/baffle
Outlet sanitary T/baffle
Effluent filter (if part of design)
Condition of tank material
Tank was pumped for inspection
If YES, list the pumping company
If NO, when was the last pumping
Scum level (1st compartment)inches inches inches
Sludge level (1st compartment)inches inches inches
Scum level (2nd compartment)inches inches inches
Sludge level (2nd compartment)inches inches inches
Backflow (if pumped)
Midtank baffle
Watertightness
PUMPS/DOSING SIPHONS:
Is a pump or dosing siphon present?YES NO
If YES, is the pump/dosing siphon functioning properly?PASS FAIL
Does the pump/wiring/dosing siphon appear to be in good condition?PASS FAIL
Is the high water alarm working, both visible and audible?PASS FAIL
SECONDARY TREATMENT:
Is a secondary treatment unit present?YES NO UNKNOWN
If YES, does the unit appear to be in good working condition?YES NO
Does the owner have a current maintenance contract for the unit?YES NO UNKNOWN
Maintenance Provider:_______________________________________Phone:________________________
ABSORBTION AREA:
Effluent surfacing?PASS FAIL
Evidence of past surfacing?NO YES
Surface dampness?NO YES
Excessive odors?NO YES
Field location verified by observation ports or probing:Ports Probing
Liquid in observation port?NO YES
If YES, record depth:inches
Distribution Box or ADV part of original design?YES NO UNKNOWN
If YES, is it accessible from grade?YES NO
Is it level and in good condition?PASS FAIL
If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A
copy of the contract must be submitted to Pitkin County Environmental Health Department.
Tank 1 Tank 2 Tank 3
Page 2
Any problems with the system that were not addressed in the inspection checklist?
Please list any recommendations for the continued use of the system:
Were any repairs done as a result of this inspection?NO YES
If YES, please describe the repairs.
Licensed Systems Inspector Signature:
Additional Notes:
To the best of my knowledge and training, the information collected in this inspection is accurate as of
__________________, 20____.
Clearly label any pictures and attach them to this form.
Page 3
CBO Inc.
33 Four Wheel Drive Road
Carbondale, CO 81623
cell) 970-309-5259 office) 970-704-0484
carla.ostberg@gmail.com
June 9, 2018
Jack Wheeler
wheelerjiv@gmail.com
Onsite Wastewater Treatment System (OWTS) Use Permit Inspection
23050 Frying Pan Road
Pitkin County, Colorado
Jack,
As requested, CBO Inc. performed an Onsite W astewater Treatment System (OWTS) Use Permit
inspection at 23050 Frying Pan Road, Meredith, Colorado on June 5, 2018. The legal description of the
10.741-acre property is Lot 4, Wheeler Family Subdivision.
No records were available from Pitkin County Environmental Health Department (Parcel ID #2471-132-
01-004). However, you recall pulling a permit through Environmental Health when the residence was
constructed. Enclosed is a Certificate of Occupancy and the Building Permit Application which indicates
sign off from the Environmental Health Department. These documents indicate a permit for the OWTS
existed; however, it was not able to be located at the time of this inspection.
The subject OWTS consists of one 1000-gallon, two-compartment concrete septic tank followed by a
drywell or seepage pit.
The septic tank is located to the southwest of the residence. No clean out was observed between the
house and the septic tank. Altitude Septic ran a camera through the sewer line from the house to the
septic tank in an inspection for the buyer and found a portion of the pipe that has settled. We
recommend this portion of pipe be excavated and reset in a well-bedded trench with a minimum 2%
slope to the septic tank.
Both septic tank lids were within 8-inches of grade. A poly riser was added to the outlet side of the septic
tank. We recommended the original concrete lid be removed for access as it’s difficult to remove with the
poly riser and it is not necessary to have both lids. Both inlet and outlet tees were present. We typically
recommend the addition of an effluent filter to the outlet tee; however, this tee is tucked under the lid of
the septic tank making installation impossible without extending the tee.
We measured solids in the septic tank and found approximately 18-inches of sludge in the inlet side of
the tank and 18-inches of sludge in the outlet side of the septic tank. The septic tank should be
pumped prior to issuance of the OWTS Use Permit. The invoice from pumping must be provided with
the OWTS Use Permit Application Packet.
Effluent gravity flows to a drywell, or seepage pit, approximately 10-feet from the septic tank. There was
no access to the seepage pit at the time of our inspection; therefore, this component could not be
inspected. You described the seepage pit as being constructed without concrete manhole rings. If the
seepage pit is simply a pipe entering gravel, there is no way to make this accessible for future monitoring.
We walked the approximate area of the seepage pit and found no evidence of surface saturation or
failure at the time of our inspection. This evaluation is not a guarantee of future system performance.
This inspection is good for one year.
0027.2018.POWU
Recommendations:
• Excavation and reset settled portion of sewer line between house and septic tank in a well-
bedded trench with a minimum 2% slope to the septic tank.
This report, pumping invoice, and a completed OWTS Use Permit Application must be submitted to
the Pitkin County Environmental Health Department. Applications may be submitted to Pitkin County
Environmental Health Department electronically. The following are links to the required OWTS Use Permit
Application and Checklist.
Application: http://www.pitkincounty.com/DocumentCenter/Home/View/621
Application Checklist: http://www.pitkincounty.com/DocumentCenter/Home/View/620
All questions regarding permit submission can be directed to Pitkin County Environmental Health
Department, 970-920-5070.
Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS
based upon what was observed and the Licensed Inspector’s expertise in onsite wastewater technology.
The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any
period of time in the future. Because of numerous factors which may affect the operation of an OWTS,
as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this
report shall not be construed as a warranty by the Inspector that the system will function properly for any
particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied,
arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the
system is having on groundwater.
Please call with questions.
Sincerely,
Carla Ostberg, MPH, REHS
NAWT Certified Inspector
Certification # 11044ITC Exp. April 2020
0027.2018.POWU
View of septic tank lids Inlet tee
Outlet tee (tucked under lid) baffle (showing signs of deterioration)
0027.2018.POWU
0027.2018.POWU
23050 Frying Pan Road Legend
70 ft
N
➤➤
N
0027.2018.POWU
0027.2018.POWU
0027.2018.POWU
832‐R‐13‐002
0027.2018.POWU
INVOICE
Date
6/12/2018
Invoice #
1662
Bill To
23050 Frying Pan Rd
Altitude Septic, LLC
PO Box 1534
Eagle, CO 81631
Total
Balance Due
Payments/Credits
970-471-0913
AltitudeSeptic@gmail.com
AltitudeSeptic.com
Due Date
Due upon receipt
DescriptionQuantity Unit Price Amount
Dump Fee WGS Sanitation1,000 0.20 200.00
1,000 0.30 300.00
Any balance not paid in 30 days will incur a 3% interest charge.$500.00
$500.00
$0.00
0027.2018.POWU