HomeMy WebLinkAboutPitkin.EH.247113201004 (2018)Page | 1 Pitkin County Environmental Health Department Onsite Wastewater Treatment System (OWTS) USE PERMIT Permit for Continued Use of an Existing OWTS 76 Service Center Road, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 www.aspenpitkin.com/EHNR Parcel ID #: 2471-132-01-004 OWTS Use Permit #: 0027.2018.POWU Date Issued: 06/12/2018 Issued By: Kurt Dahl Expiration Date: 06/12/19 Owner(s): John H. Wheeler IV and Stephanie C. Wheeler Property Address: 23050 Frying Pan Rd Legal Description: Lot 4 Wheeler Family Subdivision Licensed Inspector: Carla Ostberg Inspection Date(s): 06/05/2018 SYSTEM INFORMATION Components Type Capacity/Size Primary Treatment Unit Concrete two-compartment septic tank 1000 gallons Secondary Treatment Unit Absorption Area Seepage Pit Unknown Other System Components OWTS Use Status: In use at the time of the inspection. Not in use at the time of the inspection.* *If the OWTS was not in use at the time of the inspection, it is recommended that the system be re-evaluated when it is in use for a more accurate evaluation of the system. System Records: Permit #: 87040 Date of Issuance: 08/19/1987 Date of Final Approval: 08/19/1987 # of Bedrooms or fixtures served by OWTS: This system was designed for 3 bedrooms. Operational Status: The inspector indicates the system is functioning properly at the time of inspection and there were no indications of failure. The OWTS record for this system could not be located but information on the permit was located from the OWTS log. Inspector Recommendations: Excavate and reset settled portion of sewer line between house and septic tank. Department Recommendations: Annual maintenance. Issuance of this OWTS Use Permit is based solely on the conditions observed and reported by the inspector to the Department on the date of the inspection(s) and on Department records at the time of permitting. The issuance of this permit does not constitute a guarantee, warranty, or representation by the Department that the system will operate properly or will not fail or that the system will not be subject to future enforcement action to correct non-compliant conditions. Estimated capacity of the system has been listed on the permit and we recommend that you monitor and/or meter water use to prevent overuse and possible failure. Owner's Name: Address: Parcel Number: Inspection Date: Pitkin County Systems Inspector License Number: QUESTIONS FOR PROPERTY OWNER PRIOR TO INSPECTION: Is the home currently occupied?YES NO If NO, how long has the home been vacant? How many bedrooms are in the home? RECORDS: Were system records available from Pitkin County?YES NO If YES:Permit number: ___________ Date of Final Approval: _________ # of bedrooms permitted: ___________ Was an as-built drawing available?YES NO Is the as-built drawing accurate? YES NO If NO: SITE CONDITIONS: Proper grading, no evidence of erosion?PASS FAIL Improper vegetative cover?NO YES Evidence of compaction such as heavy machinery or livestock?NO YES Improper discharges such as straight pipes?PASS FAIL Evidence of high ground water?NO YES Snow cover present?NO YES Any question marked FAIL will require correction before an OWTS Use permit is issued. If secondary treatment is used, who is the maintenance provider? Complete a drawing of the system on last page of this form as accurately as possible. Email: Inspector's Name: Business Name: A copy of this inspection report will be remitted to Pitkin County Environmental Health Department by the Licensed Systems Inspector within 60 days of the inspection regardless of whether the system passes or fails. Onsite Wastewater Treatment Systems (OWTS) Use Permit Inspection Form Inspection form for continued use of an existing OWTS Website: Pitkin County Environmental Health Department 76 Service Center Rd, Aspen, CO 81611 Phone: 970-920-5070 Fax: 970-920-5374 Phone Number Page 1 TANK: Tank capacity gallons gallons gallons Tank material # of compartments Date of last pumping Lids/risers in good condition Risers to grade Riser height Riser condition/watertightness Inlet sanitary T/baffle Outlet sanitary T/baffle Effluent filter (if part of design) Condition of tank material Tank was pumped for inspection If YES, list the pumping company If NO, when was the last pumping Scum level (1st compartment)inches inches inches Sludge level (1st compartment)inches inches inches Scum level (2nd compartment)inches inches inches Sludge level (2nd compartment)inches inches inches Backflow (if pumped) Midtank baffle Watertightness PUMPS/DOSING SIPHONS: Is a pump or dosing siphon present?YES NO If YES, is the pump/dosing siphon functioning properly?PASS FAIL Does the pump/wiring/dosing siphon appear to be in good condition?PASS FAIL Is the high water alarm working, both visible and audible?PASS FAIL SECONDARY TREATMENT: Is a secondary treatment unit present?YES NO UNKNOWN If YES, does the unit appear to be in good working condition?YES NO Does the owner have a current maintenance contract for the unit?YES NO UNKNOWN Maintenance Provider:_______________________________________Phone:________________________ ABSORBTION AREA: Effluent surfacing?PASS FAIL Evidence of past surfacing?NO YES Surface dampness?NO YES Excessive odors?NO YES Field location verified by observation ports or probing:Ports Probing Liquid in observation port?NO YES If YES, record depth:inches Distribution Box or ADV part of original design?YES NO UNKNOWN If YES, is it accessible from grade?YES NO Is it level and in good condition?PASS FAIL If there is no maintenance contract, a contract must be in place prior to occupancy of the home. A copy of the contract must be submitted to Pitkin County Environmental Health Department. Tank 1 Tank 2 Tank 3 Page 2 Any problems with the system that were not addressed in the inspection checklist? Please list any recommendations for the continued use of the system: Were any repairs done as a result of this inspection?NO YES If YES, please describe the repairs. Licensed Systems Inspector Signature: Additional Notes: To the best of my knowledge and training, the information collected in this inspection is accurate as of __________________, 20____. Clearly label any pictures and attach them to this form. Page 3 CBO Inc. 33 Four Wheel Drive Road Carbondale, CO 81623 cell) 970-309-5259 office) 970-704-0484 carla.ostberg@gmail.com June 9, 2018 Jack Wheeler wheelerjiv@gmail.com Onsite Wastewater Treatment System (OWTS) Use Permit Inspection 23050 Frying Pan Road Pitkin County, Colorado Jack, As requested, CBO Inc. performed an Onsite W astewater Treatment System (OWTS) Use Permit inspection at 23050 Frying Pan Road, Meredith, Colorado on June 5, 2018. The legal description of the 10.741-acre property is Lot 4, Wheeler Family Subdivision. No records were available from Pitkin County Environmental Health Department (Parcel ID #2471-132- 01-004). However, you recall pulling a permit through Environmental Health when the residence was constructed. Enclosed is a Certificate of Occupancy and the Building Permit Application which indicates sign off from the Environmental Health Department. These documents indicate a permit for the OWTS existed; however, it was not able to be located at the time of this inspection. The subject OWTS consists of one 1000-gallon, two-compartment concrete septic tank followed by a drywell or seepage pit. The septic tank is located to the southwest of the residence. No clean out was observed between the house and the septic tank. Altitude Septic ran a camera through the sewer line from the house to the septic tank in an inspection for the buyer and found a portion of the pipe that has settled. We recommend this portion of pipe be excavated and reset in a well-bedded trench with a minimum 2% slope to the septic tank. Both septic tank lids were within 8-inches of grade. A poly riser was added to the outlet side of the septic tank. We recommended the original concrete lid be removed for access as it’s difficult to remove with the poly riser and it is not necessary to have both lids. Both inlet and outlet tees were present. We typically recommend the addition of an effluent filter to the outlet tee; however, this tee is tucked under the lid of the septic tank making installation impossible without extending the tee. We measured solids in the septic tank and found approximately 18-inches of sludge in the inlet side of the tank and 18-inches of sludge in the outlet side of the septic tank. The septic tank should be pumped prior to issuance of the OWTS Use Permit. The invoice from pumping must be provided with the OWTS Use Permit Application Packet. Effluent gravity flows to a drywell, or seepage pit, approximately 10-feet from the septic tank. There was no access to the seepage pit at the time of our inspection; therefore, this component could not be inspected. You described the seepage pit as being constructed without concrete manhole rings. If the seepage pit is simply a pipe entering gravel, there is no way to make this accessible for future monitoring. We walked the approximate area of the seepage pit and found no evidence of surface saturation or failure at the time of our inspection. This evaluation is not a guarantee of future system performance. This inspection is good for one year. 0027.2018.POWU Recommendations: • Excavation and reset settled portion of sewer line between house and septic tank in a well- bedded trench with a minimum 2% slope to the septic tank. This report, pumping invoice, and a completed OWTS Use Permit Application must be submitted to the Pitkin County Environmental Health Department. Applications may be submitted to Pitkin County Environmental Health Department electronically. The following are links to the required OWTS Use Permit Application and Checklist. Application: http://www.pitkincounty.com/DocumentCenter/Home/View/621 Application Checklist: http://www.pitkincounty.com/DocumentCenter/Home/View/620 All questions regarding permit submission can be directed to Pitkin County Environmental Health Department, 970-920-5070. Disclaimer: This inspection is intended only as an evaluation of the present condition of the OWTS based upon what was observed and the Licensed Inspector’s expertise in onsite wastewater technology. The Inspector has not been retained to warrant or guarantee the proper functioning of the system for any period of time in the future. Because of numerous factors which may affect the operation of an OWTS, as well as the inability of the Inspector to supervise or monitor the use or maintenance of this OWTS, this report shall not be construed as a warranty by the Inspector that the system will function properly for any particular prospective buyer, and the Inspector disclaims any warranty, either expressed or implied, arising from the inspection of the OWTS or this report. The evaluation does not ascertain the impact the system is having on groundwater. Please call with questions. Sincerely, Carla Ostberg, MPH, REHS NAWT Certified Inspector Certification # 11044ITC Exp. April 2020 0027.2018.POWU View of septic tank lids Inlet tee Outlet tee (tucked under lid) baffle (showing signs of deterioration) 0027.2018.POWU 0027.2018.POWU 23050 Frying Pan Road Legend 70 ft N ➤➤ N 0027.2018.POWU 0027.2018.POWU 0027.2018.POWU 832‐R‐13‐002 0027.2018.POWU INVOICE Date 6/12/2018 Invoice # 1662 Bill To 23050 Frying Pan Rd Altitude Septic, LLC PO Box 1534 Eagle, CO 81631 Total Balance Due Payments/Credits 970-471-0913 AltitudeSeptic@gmail.com AltitudeSeptic.com Due Date Due upon receipt DescriptionQuantity Unit Price Amount Dump Fee WGS Sanitation1,000 0.20 200.00 1,000 0.30 300.00 Any balance not paid in 30 days will incur a 3% interest charge.$500.00 $500.00 $0.00 0027.2018.POWU