Loading...
HomeMy WebLinkAboutPolymeric Based Building Products in Wildfire Resiliency Code 07.29.2026 July 15, 2026 RE: Polymeric Exterior Products Association (PEPA) and the Fenestration and Glazing Industry Alliance (FGIA), July 10, 2026 letter: Opposition to the Ban on Polymeric Building Products Dear Pitkin County Commissioners, Pitkin County appreciates PEPA and FGIA's support for advancing wildfire resilience and recognizes that many polymeric building products have successfully demonstrated compliance with nationally recognized testing standards under specific laboratory conditions. However, the County respectfully disagrees that its local amendments are inconsistent with the intent of the Colorado Wildfire Resiliency Code (CWRC) or that they unnecessarily prohibit otherwise code-compliant building products. The CWRC establishes a minimum statewide standard intended to provide a baseline level of wildfire protection across a broad range of communities and wildfire hazards. Importantly, the code expressly preserves the authority of local jurisdictions to adopt more restrictive provisions where warranted by local conditions. Pitkin County's amendments reflect its unique combination of steep topography, dense wildland fuels, frequent wind-driven fire conditions, and limited evacuation routes. Collectively, these factors support a more conservative approach to structural hardening than the statewide minimum requirements. While PEPA and FGIA correctly note that certain polymeric products may be incorporated into wall assemblies that achieve ASTM E119 fire-resistance ratings, those test results should not be interpreted as representative of wildfire performance. ASTM E119 evaluates the fire resistance of a complete wall assembly under controlled furnace conditions and is intended to measure the duration that an assembly maintains its structural integrity when exposed to a standardized interior fire. It does not evaluate the performance of exposed exterior materials subjected to radiant heat, direct flame impingement, wind-driven embers, or prolonged wildfire exposure. Consequently, a one-hour fire-resistance rating should not be construed as evidence that all individual components remain intact or provide equivalent performance during a wildland fire. 530 E. Main Street, Suite 205, Aspen, CO 81611 During the County's code amendment process, staff reviewed available research on the performance of exterior building materials under wildfire conditions. That research found that vinyl and other polymer-based products used for siding, windows, doors, and fencing adjacent to structures generally do not maintain their protective function when exposed to the extreme radiant heat and direct flame conditions characteristic of wildfires. Research conducted by the National Institute of Standards and Technology (NIST) has demonstrated that vinyl can melt, shrink, and pull away from the wall assembly, exposing combustible substrates and increasing the potential for ember intrusion and flame penetration. NIST has also documented that the thermal decomposition and combustion of PVC-based products can release hazardous combustion products, including hydrogen chloride and carbon monoxide. While these materials may perform acceptably under conventional building fire scenarios, their behavior during prolonged exterior wildfire exposure differs significantly from the conditions represented by standardized laboratory testing. The County's restrictions on polymeric window frames are similarly based on long-term wildfire resilience rather than state minimum code compliance. Post-fire investigations and wildfire research have consistently identified windows as one of the most vulnerable components of the building envelope. Although glazing failure often initiates assembly failure, elevated temperatures can also soften or deform polymeric frames, potentially compromising weather seals, reducing frame rigidity, and increasing the likelihood of ember intrusion following glazing breakage. Additionally, warping and deformation can contribute to glazing failure. Noncombustible framing materials provide an additional layer of passive protection by maintaining greater structural stability under prolonged heat exposure and reducing reliance on the performance of individual components during extreme fire events. Similarly, the County's prohibition on polymeric fencing immediately adjacent to structures is intended to reduce opportunities for fire spread. Numerous wildfire mitigation organizations, including CAL FIRE and the University of California Fire Network, recommend replacing combustible fencing with noncombustible materials in the area immediately surrounding structures because attached fencing can serve as a pathway for flame spread to the primary building. Polymer fencing may also soften, deform, or fail under wildfire exposure, diminishing its effectiveness as a protective barrier and potentially creating additional hazards during emergency response operations. It is also important to distinguish between state minimum code compliance and risk reduction. The CWRC permits many products that satisfy prescribed testing criteria; however, compliance with a minimum standard does not preclude a jurisdiction from adopting more protective measures where justified by local conditions. Pitkin County has intentionally reduced the use of combustible exterior materials wherever practical to improve overall community resilience and reduce the likelihood of structure ignition during extreme wildfire events. Similar local amendments have been adopted by jurisdictions throughout Colorado and the western United States where wildfire hazards exceed those contemplated by minimum statewide standards. 530 E. Main Street, Suite 205, Aspen, CO 81611 Finally, the County's amendments should be viewed as one component of a comprehensive wildfire mitigation strategy rather than as isolated material restrictions. The limitations on combustible exterior products complement requirements for ignition-resistant construction, ember-resistant detailing, defensible space, and noncombustible zones immediately adjacent to structures. Collectively, these measures create multiple layers of protection, reduce dependence on any single building component, and improve the overall resilience of structures exposed to severe wildfire conditions. For these reasons, Pitkin County believes its local amendments are supported by available scientific research, justified by the County's unique wildfire risk profile, consistent with the authority granted to local governments under Colorado law, and represent a reasonable exercise of the County's responsibility to protect life, property, critical infrastructure, and the long-term resilience of its communities. Below is a list of scientific citations that support our research: NIST Technical Note 2304 – documents vinyl siding melting, shrinking, and loss of fire-barrier function. NIST firebrand exposure studies (Manzello et al.) – demonstrates ember-driven ignition and failure of vinyl siding assemblies. CAL FIRE Home Hardening Guide – recommends noncombustible fencing adjacent to structures to reduce fire spread. University of California ANR Fire Network – identifies vinyl fencing as susceptible to melting and recommends noncombustible materials near homes. University of California ANR Fire Network - identifies vinyl windows deformed as a result of a radiant exposure from neighboring home that had ignited and was ultimately destroyed. Insurance Institute for Business & Home Safety (IBHS) Wildfire Prepared Home guidance – emphasizes noncombustible materials and the importance of the first five feet around structures. Fire Safety Research Institute, UL Research Institutes - investigates window frame failure modes during exterior fire exposure. Vinyl assemblies had both the largest number of sash failures and contributed the most to out-of-plane stress on glass panes University of Maryland / NIST Window Fire Testing - concludes that vinyl-frame windows did not perform well under the exposure of imposed heat fluxes. Vinyl frames and sashes lost strength, distorted and sagged, permitting openings to develop. NIST Technical Note 2153- documents that vinyl window frames can soften and deform when exposed to elevated radiant heat, potentially releasing the glazing and creating an opening through which embers or flames may enter the structure. While glazing failure is often the 530 E. Main Street, Suite 205, Aspen, CO 81611 initiating event, maintaining the integrity of the window frame under prolonged thermal exposure is an important component of wildfire-resistant construction. Sincerely, Jeffrey Erickson, Chief Building Official Jeffrey H. Woodruff Pitkin County Board of County Commissioners, Board Chair 530 E. Main Street, Suite 205, Aspen, CO 81611