HomeMy WebLinkAboutpitkin.bldg.264316190117 (2)LAYOUT Certificate of Occupancy or Letter of Completion ', (most recent project) Permits Final Inspections Any Supporting Documents Site Plans (no architectural plans) If there are previous projects they will follow in the same order. ~1 C0 l i_ i f nmmnnity-avalnnmanfllanartmani -November 9, 2005 To: Alan Becker 950 Matchless Drive ' Aspen CO 81611 Fax 925-7224 From: Tony Fusazo Chief Building Official Pitlcin County Re:. Pre-HUD mobile home at : ` oo y ree < obile~F3ome Parke Alan, This is a follow-up to my site visit of September 20, 2005. I understand that the mobile ` home that you own in Woody`Creelc Mobile Home Park is forced to relocate to another location within the Park due to actions of the Aspen Pitkin County Housing Authority. According to'codes adopted by Pitkin County, a building which is moved to another location is required to be brought up to current code standards. Because of these unique circtunstances, which were enacted to increase the overall safety level of the Park, I will continue to "grandfather" the status of your mobile home on the condition thaf'you agree to make certain minimtun safety, improvements. The improvements are as follows:.l) provide both bedrooms with egress windows that meet the minimum standards of International Residential Code section R310; 2) install smoke alazms at locations that comply with IRC secfion R313; 3) call for an electrical inspection by the County electrical inspector to verify that,the polarity of all receptacles is correct and that the service panel is properly grounded; and have any deficiencies that he notes corrected. I am including copies of the code sections that I mentioned above.. If this is. acceptable to you, please take out a building repair permit before making these improvements. You need not pull an electrical permit for the electrical inspection, but an hourly fee. will be charged for time spent. Once you have passed the final inspections, we will be able to issue a Letter of Completion, which will enable you to move the mobile home to its new location within the Park. , If you have any questions, please call me of 920-5101.. Regards, ~~~-~--- -Tony Fusato ' Chief Building Official Pitkin Cotmty a~ J 30 5. Galena Street Aspen, Colorado 8161 I ~ r~^k ~ ~° % ri (970) 920-5526 fax 920-5439 www.aspenpitkin.com 8310.1 Emergency escape and rescue required. Basements with habitable space and every sleeping room shall have at least one openable emergency escape and rescue opening. Where basements contain one or more sleeping rooms, emergency egress and rescue openings shall be required in each sleeping room, butt shall not be required in adjoining areas of the basement. Where emergency escape and rescue openings are pro-vided they shall have a sill height of not more than 44 inches (1118 mm) above the floor. Where a door opening having a threshold below the adjacent ground elevation serves as an emergency escape and rescue opening and is provided with a bulkhead enclosure, the bulkhead enclosure shall comply with Section 3 f0.3. The net cleaz opening dimensions required by this section shall be obtained by the normal operation of the emergency escape and rescue opening from the inside. Emer-gency escape and rescue openings with a finished sill height be-low the adjacent ground elevation shall be provided with a window well in accordance with Section 8310.2. 8310.1.1 Minimum opening area. All emergency escape and rescue openings shall have a'minimum net clear opening of 5.7 square feet (0.530 mz). Exception: Grade floor openings shall have a minimum net clear opening of 5 square feet (0.465 mz). 8310.1.2 Minimum opening height. The minimum net cleaz opening height shall be24 inches (610 mm). 8310.1.3 Minimum opening width. The minimum. net clear opening width shall be 20 inches (508 mm). 8310.1.4 Operational constraints. Emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. 8311.5.8.2. 8310.4 Bars, grills, covers and screens. Bars, grills, covers, screens or similar devices aze permitted to be placed over emergency escape and rescue openings, bulkhead enclosures, or window wells that serve such openings, provided the minimum net clear opening size complies with Sections 8310.1.1 to 8310.1.3, and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening. [F] 8313.1 Smoke alarms. Smoke alarms shall be installed in the following locations: 1. In each sleeping room. 2._Outside each sepazate sleeping area in the immediate vicinity of the bedrooms. i 3._On each additional story of the dwelling, including basements but not including crawl spaces and uninhabitable attics.7n dwellings ordwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. I III